AirGreenLG
LG · Air handler · KNSLB · KNSLAThe LG air handler at AirGreenSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
My thermostat
What it is

The coil and blower of the central system

It takes the furnace’s place, blows into the same ductwork and houses the electric heat kit when one is needed. The main heat comes from the heat pump; the heat kit is backup.

LG’s names

  • LG Canada: “Vertical Air Handler Unit” and “Multi-Position Air Handler”.
  • LG U.S.: “Multi-Position Air Handling Unit” (MPAHU).
  • At AirGreen, some product titles also say “blower cabinet”: it is the same unit.

Two families, several outdoor units

  • KNSLB: 1 to 5 tons at LG, 1 to 4 tons here, for the standard central and for the LGRED° at 3.5 and 4 tons.
  • KNSLA: 1.5 to 3 tons, LGRED° only.
  • Per LG Canada, it pairs with single-zone outdoor units, standard or LGRED°, and with Multi F and Multi F MAX multi-zone units.

LG Canada puts its heating efficiency at up to twice that of electric heating.

Where it fits

Four positions, one unit

LG Canada calls it multi-position: the same unit goes in standing up or lying down, depending on the space and the direction of the ducts.

UpflowStanding, air leaves at the top.
DownflowStanding, air leaves at the bottom. Needs an LG accessory; the PNDFA0 kit appears on the KSSLA361A spec sheet.
Horizontal leftLying flat, air leaves to the left.
Horizontal rightLying flat, air leaves to the right.
Airflow and ducts

The airflow of each size

From 500 to 1,400 CFM at high speed, from the 1-ton to the 4-ton. That is the airflow your ducts must carry; we check them during the visit.

High-speed airflow per LG’s installation guide; it matches our listings. Links go to the product pages in this collection.
SizeMax. airflow (CFM)Standard centralLGRED°
1 ton500KNSLB121Anot offered
1.5 tons600KNSLB181AKNSLA181A
2 tons800KNSLB241AKNSLA241A
2.5 tons875KNSLB301AKNSLA301A
3 tons1,050KNSLB361AKNSLA361A
3.5 tons1,225KNSLB421AKNSLB421A
4 tons1,400KNSLB481AKNSLB481A

Constant-airflow motor

The centrifugal blower is driven by a brushless DC constant-airflow motor, for an external static pressure of 0.1 to 1.0 in. w.c..

Static pressure is set with an LG wall control (setting FC3, from 000 to 255). It can be plugged in for the adjustment, then removed.

Electric backup

Six LG heat kits, 3 to 20 kW

The kit slides into the air handler and takes over when the heat pump is no longer enough. Its size depends on the home’s load and on what the electrical panel can supply.

ANEH series, 208/230 V, single phase (LG installation guide).
LG kitOutputPower supplies
ANEH033C13 kWone
ANEH053C15 kWone
ANEH083C28 kWone
ANEH103C210 kWone
ANEH153C315 kWtwo
ANEH203C320 kWtwo

The wiring

  • The 15 and 20 kW kits need two power supplies: we check the electrical panel’s capacity before offering them.
  • With an LG kit, DIP switch SW6 turns on the automatic link, and SW5 the continuous fan.
  • Each kit’s fit with each size and the breaker ratings are confirmed in LG’s manual, on the quote.

Our shop carries the LG electric heat kit for the air handler; the output is chosen with you.

The thermostat

LG control or 24 V thermostat: what changes

Both work. The difference is in what the thermostat controls.

  • Standard III PREMTB101: the LG wall control, sold here.
  • CRC2: the other wall control LG names for this unit; we confirm its model on the quote.
  • PWFMDD200: LG ThinQ Wi-Fi module, optional.
  • The LG wireless remote requires an LG wall control.
  • The wall control is also used to set the static pressure (FC3).
  • The LG PDRYC320 accessory is required. We do not sell it online.
  • It accepts a conventional thermostat or an O or B heat pump thermostat, selected with DIP switch SW4.
  • Limit: that thermostat does not drive the LG electric heat kit.
  • Factory settings stay as they are, static pressure included; to adjust it, we plug in an LG wall control for the setting.

LG quick installation guide (IN_SZ_MPAHU_R32_07_25) and LG KSSLA361A spec sheet.

At installation

Six details worth knowing

  1. FilterField-supplied, housed behind one of the unit’s access panels.
  2. 15 AThe unit can be powered separately, on a 208/230 V, 15 A circuit.
  3. OverflowThe condensate overflow switch is third-party; LG supplies the wiring diagrams.
  4. LeakRefrigerant leak sensor, tied to DIP switch SW8.
  5. HeliumThe unit ships under a dry helium holding charge.
  6. 5 tLG publishes the KNSLB up to 5 tons; our line stops at 4.
Your situation

Keeping your current furnace

The LG coil on another furnace

LG also publishes an LKMMA coil that sits on another maker’s furnace and is powered at 24 V by it (for example the KSSMA36CA system: KUSXA361A and LKMMA36C1). We do not sell it online.

Any work on a gas or oil furnace is handed to a partner holding the required licence. And per its guide, LogisVert covers homes heated mainly by electricity.

The heat pump’s numbers

Cold output, standard or LGRED°, LogisVert amounts size by size: all of that depends on the outdoor unit and is on the LG central heat pump page.

No LG air handler job is published in our project gallery yet.

See our LG projects
Frequently asked questions

What people ask us most

Is it a furnace or a heat pump?
It is the indoor part of an LG central heat pump: the coil and blower. An LG electric heat kit is added for backup. Our listings in this collection are sold with their outdoor unit.
Can I keep my current thermostat?
If it is 24 V, yes, with LG’s PDRYC320 accessory. It will not drive the LG electric heat kit, though.
What size of electric heat kit do I need?
LG offers six kits, from 3 to 20 kW. We choose based on the home’s load and the panel’s capacity: the 15 and 20 kW need two power supplies.
Can it be installed lying down?
Yes, horizontal left or right. The downflow position needs an LG accessory. In an attic outside the insulated envelope, the central system loses its LogisVert eligibility.
Where is the filter?
Behind one of the unit’s access panels. The filter is field-supplied, not by LG: we choose it at installation.
Does it work with a multi-zone heat pump?
LG Canada lists it as compatible with Multi F and Multi F MAX multi-zone units, standard or LGRED°. See the LG multi-zone page.

Sources checked

  1. LG Electronics Canada, “Vertical Air Handler Unit” page (FR and EN), read October 14, 2026.
  2. LG Electronics U.S.A., R32 Single Zone MPAHU Quick Installation Guide (IN_SZ_MPAHU_R32_07_25) and R32 Single Zone LGRED Multi-Position Air Handling Unit KSSLA361A spec sheet.
  3. LG Electronics U.S.A., R-410A to R-32 Model Numbers (CR_R410A_Models_to_R32_06_25) and the KSSMA36CA system sheet (LKMMA36C1 coil).
  4. Hydro-Québec, LogisVert participation guide version 1.10 (September 15, 2026).
  5. AirGreen, airgreen.ca product pages, October 27, 2026.

LogisVert amounts and LG’s warranty are explained on the LG page. Prices on quote.

The LG air handler shop

Our LG air handlers, right below.

Each product page is sold as a complete system with its KUSX outdoor unit and its AHRI number.