A 115 V version existed
TOSOT also published a 115 V Lomo 16: TW09HQ1B8A and TW12HQ1B8A.
TOSOT “Heat Pumps” catalogues 2020 (V13) and 2022.
Find the model on the nameplate, pick it here: you get the output, the refrigerant, the factory charge and the electrical values from the TOSOT catalogue.
The model is on the nameplate: TW..HQ1C8DI on the head, TW..HQ1C8DO on the outdoor unit. Pick yours: here are the TOSOT catalogue numbers to give the technician.
Model
TW12HQ1C8D: 12,000 BTU/h in cooling, R-410A, 30.0 oz factory charge, MCA 9 A and MOCP 15 A.
Source: TOSOT “Heat Pumps” catalogue 2020 (V13).
Each product page: indoor and outdoor models, AHRI number and technical details.
TOSOT also published a 115 V Lomo 16: TW09HQ1B8A and TW12HQ1B8A.
TOSOT “Heat Pumps” catalogues 2020 (V13) and 2022.
The TOSOT catalogue rates heating down to -20 °C, with a heater built into the drain pan.
TOSOT catalogue 2020 (V13) and TOSOT French brochure.
The factory R-410A charge runs from 24.7 oz on the 9,000 BTU/h to 65.3 oz on the 24,000 BTU/h.
TOSOT catalogue 2020 (V13).
Two R-410A series, the same sizes: what changes according to TOSOT’s documents.
| Model | SEER (old method) | Heating down to | Line, max. length | Wi-Fi |
|---|---|---|---|---|
| Lomo 16 · 9,000 | 16 | -20 °C | 49.2 ft | Not listed |
| Lomo 23 · 9,000 | 23.0 | -20 °C (submittal) | 49 ft | Optional kit |
| Lomo 16 · 12,000 | 16 | -20 °C | 49.2 ft | Not listed |
| Lomo 23 · 12,000 | 22.0 | -20 °C (submittal) | 66 ft | Optional kit |
Lomo 16: TOSOT catalogue 2020. Lomo 23: TOSOT submittals TW09HQ2C2D and TW12HQ2C2D.
We look at the room, the insulation and the electrical panel, then we propose the model, the quote and the LogisVert amount that applies.
The Lomo 16 numbers come from the TOSOT catalogue; no AHRI number is published for this series.