AirGreenTRANE
RunTru 17 SeriesTRANE RunTru 17 wall heat pump, 9,000 to 24,000 BTU/hSold and installed by AirGreen. We install across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The whole TRANE space
RunTru 17 Series

TRANE RunTru 17: which room, and down to what cold?

4 sizes, 9,000 to 24,000 BTU/h, using R-410A. Trane rates it for heating down to −20 °C. To pick a RunTru 17 size, start from the room: its area, how much sun it gets, the people who use it and whether it is a kitchen.

Updated October 29, 2026. Figures from Trane’s documents and the sources listed at the bottom of the page.
4sizes on this page
−20 °Cpublished heating limit, per Trane
14,200BTU/h at −20 °C, the 24,000
16 to 18SEER2, depending on size
Our reading of the figures

For a 25 m² room, ENERGY STAR’s cooling guide gives 7,000 BTU/h: the 9,000 RunTru 17 covers it. For heating, it still gives 4,300 BTU/h at −20 °C, its limit per Trane. Below −20 °C (on average 14.3 days a year in Montreal, 1981–2010 normals), another heat source is needed; above it, it all depends on how much heat the room loses, and the on-site visit tells you.

Sold and installed by AirGreenPublished heating down to −20 °CIndoors from 26 dB(A) at 1 mFree on-site estimate
The models

The 4 RunTru 17 units

Price on quote, after the free on-site estimate.

R-410A9,000 to 24,000 BTU/h
TRANE
TRANETRANE
01 · Room by room

Which RunTru 17 for which room?

Set the area, the sun, the people and the kitchen: the tool reads ENERGY STAR’s cooling table, takes a guide figure from it, then gives the smallest RunTru 17 that reaches it and the heat Trane publishes for it at −20 °C.

10 m²130 m²
Sun
People
Kitchen
ENERGY STAR cooling guide figure
7,000BTU/h

Band 23.2 to 27.9 m² (250 to 300 sq ft): 7,000 BTU/h, no adjustment.

The smallest RunTru 17 that reaches it

9,000 BTU/h RunTru 17

  • Rated cooling9,100 BTU/h
  • Heat at −20 °C, room at 20 °C4,300 BTU/h
  • Days below −20 °C in Montreal14.3 a year
See the 9,000 BTU/h RunTru 17

ENERGY STAR cooling guide figure, not a load calculation: the on-site visit sets the size. ENERGY STAR’s table is for choosing a room air conditioner (8 ft ceiling, 2.44 m); it does not say how much heat the room needs in winter, and the RunTru 17 is not ENERGY STAR certified (list checked October 28, 2026). Rated cooling: Trane sell sheet 26-1061-04 (2024). Heat at −20 °C: submittals M4MHW17…-SUB-1B-EN (August 5, 2022), normal operation per Trane, not certified values. Days below −20 °C: Environment and Climate Change Canada, Montreal-Trudeau, 1981–2010 normals.

TRANETRANE
02 · The four sizes

The RunTru 17 in figures, size by size

Trane figure9,000 BTU/h12,000 BTU/h18,000 BTU/h24,000 BTU/h
Rated cooling / heating9,100 / 9,500 BTU/h12,000 / 13,000 BTU/h17,400 / 18,000 BTU/h22,000 / 24,000 BTU/h
SEER2 / HSPF2 / EER217.5 / 8.4 / 10.216.5 / 8.5 / 8.716 / 8.2 / 9.518 / 8.5 / 11.6
Heat at −20 °C, room at 20 °C4,300 BTU/h6,800 BTU/h9,900 BTU/h14,200 BTU/h
Outdoor sound, at 1 m52 dB(A)52 dB(A)57 dB(A)57 dB(A)
Indoor, 7 speeds, at 1 m26 to 40 dB(A)30 to 45 dB(A)34 to 47 dB(A)37 to 51 dB(A)
Line set, liquid – gas1/4 – 3/8 in1/4 – 3/8 in1/4 – 1/2 in1/4 – 5/8 in
Longest run / highest lift15 m / 10 m20 m / 10 m25 m / 10 m25 m / 10 m
Minimum circuit ampacity9 A10 A14 A15 A
Meteringcapillary tubecapillary tubecapillary tubeelectronic valve
Outdoor unit, W × H × D732 × 555 × 330 mm, 25.5 kg732 × 550 × 330 mm, 25.5 kg802 × 555 × 350 mm, 31.5 kg958 × 660 × 402 mm, 44 kg
The modelSee the productSee the productSee the productSee the product

Sources: Trane sell sheet 26-1061-04 (2024) for rated capacities, SEER2, HSPF2 and EER2; submittals M4MHW17…-SUB-1B-EN (August 5, 2022) and installer’s guide 88-M4MHW17-1B-EN (March 16, 2023) for the rest. The 2022 submittals give other rated capacities for three sizes: 9,000 / 9,400, 11,700 / 12,000 and 17,400 / 19,100 BTU/h. Dimensions and weights converted from Trane’s inches and pounds. For the 24,000, Trane prints 20 A or 30 A as maximum circuit protection depending on the document: the nameplate governs.

TRANETRANE
03 · 17 versus 23

The same size in the other series

In the 9,000 BTU/h size, at −20 °C, the RunTru 23 gives 72% more heat than the RunTru 17.

9,000 BTU/hRunTru 17RunTru 23
Heat at −20 °C, room at 20 °C4,300 BTU/h7,390 BTU/h
Heats down to−20 °C−30 °C
SEER217.523
Meteringcapillary tubeelectronic valve

Sources: submittals M4MHW1709A and M4THS2309A-SUB-1B-EN (August 5, 2022), 20 °C column; sell sheets 26-1061-04 and 26-1063-04 (2024); 17 and 23 Series installer’s guides.

TRANETRANE
04 · Installation

What Trane requires when installing the 17 Series

The rules in the 17 Series installer’s guide. A RunTru 17 installation is checked against them.

  • The outdoor unit on a base that carries at least four times its weight.
  • At least 31.8 mm (1 1/4 in) above the ground or its base, for the drain, level, fastened firmly where winds are strong, and where condensate poses no hazard.
  • Unused base pan holes plugged.
  • Nitrogen test at 150 psig, then evacuation to 350 microns or below; if the reading keeps rising above 1,500 microns, there is a leak.
  • Interconnecting wire at least 14 AWG, 600 V, stranded, no longer than 70 m.

Source: Trane installer’s guide 88-M4MHW17-1B-EN (March 16, 2023).

TRANETRANE
05 · Owners

You already have a RunTru 17

  • Filters: a washable one, an air-purifying one and an activated carbon and catechin one; Trane’s submittal calls for cleaning at least once a year.Submittals M4MHW17…-SUB-1B-EN
  • Remote: included, with I-Feel, X-Fan and Sleep Mode.Sell sheet 26-1061-04
  • Code U4: reversing valve malfunction. That’s a job for a refrigeration technician.Installer’s guides, code list
  • Warranty: Trane’s limited parts warranty goes, in most cases, from 5 to 10 years if the unit is registered within 60 days of installation; residential and multi-family use. Labour is not covered by Trane; 6 years on labour, guaranteed by AirGreen, for installations done since October 5, 2026. RunTru registration line: 1-855-956-5685.runtruhvac.com, Warranty page; sell sheet 26-1061-04
TRANETRANE
06 · Did you know

Three RunTru 17 details

01

In cooling, the 24,000 BTU/h RunTru 17 takes 5.28 pints of water an hour out of the air, per Trane, about 2.5 L/h (our conversion).

Submittal M4MHW1724A-SUB-1B-EN
02

The RunTru 17 also comes as a cooling-only version (M4TCS / M4MCW), with the same line-set sizes.

Sell sheets 26-1061-03 and 26-1061-04
03

The 18,000 and 24,000 accept up to 25 m of line set; every size ships charged for 7.6 m, with a 3 m minimum.

Guide 88-M4MHW17-1B-EN; submittals 1718A and 1724A
07 · Questions

What people ask us about the RunTru 17

Which room is the RunTru 17 right for?
For cooling, the 24,000 RunTru 17 gives 22,000 BTU/h: with no adjustment, it covers ENERGY STAR’s guide up to the 92.9 to 111.5 m² band (21,000 BTU/h). For heating, it depends on the cold: Trane rates it for heating down to −20 °C. The Room by room tool above gives the guide figure; the on-site visit sets the size.
Does it heat below −20 °C?
Trane publishes a heating range of −20 °C to 24 °C for the 17 Series. The 2022 submittals of the 18,000 and 24,000 print a range starting at −7 °C; the 2023 installer’s guide, the more recent document, gives −20 °C, and that is the value used here. Its tables also print a −25 °C row, but it is below that limit: outside that range, it cannot be counted on. At Montreal-Trudeau, the low drops below −20 °C on average 14.3 days a year (1981–2010 normals).
Do I still need backup heat?
For nights below −20 °C, yes: Trane publishes no heating for the RunTru 17 below that temperature. Above it, the colder it gets, the less it gives: the 12,000 goes from 12,400 BTU/h at 0 °C to 6,800 BTU/h at −20 °C; the on-site visit says what the room needs.
Is there a LogisVert grant on the RunTru 17?
No, under the current rules. Trane does not present the RunTru 17 as ENERGY STAR, and no M4THS unit is in the current Canadian ENERGY STAR list (checked October 28, 2026). For a heat pump installed since November 26, 2025, Hydro-Québec requires that certification (its LogisVert residential page; participation guide, version 1.10). Only Hydro-Québec confirms the assistance granted.
Is it noisy?
Indoors, 26 to 51 dB(A) at 1 m depending on size and fan speed. At the lowest speed, 26 to 37 dB(A) at 1 m: around a low-voice conversation (30) and below a library (40) on Québec.ca’s scale. Outdoors, 52 dB(A) (9,000 and 12,000) or 57 dB(A) (18,000 and 24,000), measured 1 m from the unit.
Is Wi-Fi built in?
No. The wiring diagram in the 17 Series guide shows a Wi-Fi module as an option, with no published part number. The handheld remote is included, with I-Feel, X-Fan and Sleep Mode.
AirGreen
AirGreen × TRANE

A RunTru 17 in your home, installed by AirGreen

One visit to see the room and measure; the written quote says which RunTru 17 size to choose, and what will heat on nights below −20 °C.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work: a partner holding the required licence.
On-site estimateFree, with a written quote.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.
HoursMonday to Thursday, 8 a.m. to 6 p.m.; Friday, 8 a.m. to 4 p.m.
AirGreenTRANESold and installed by AirGreen