TRANE RunTru 17: which room, and down to what cold?
4 sizes, 9,000 to 24,000 BTU/h, using R-410A. Trane rates it for heating down to −20 °C. To pick a RunTru 17 size, start from the room: its area, how much sun it gets, the people who use it and whether it is a kitchen.
Updated October 29, 2026. Figures from Trane’s documents and the sources listed at the bottom of the page.For a 25 m² room, ENERGY STAR’s cooling guide gives 7,000 BTU/h: the 9,000 RunTru 17 covers it. For heating, it still gives 4,300 BTU/h at −20 °C, its limit per Trane. Below −20 °C (on average 14.3 days a year in Montreal, 1981–2010 normals), another heat source is needed; above it, it all depends on how much heat the room loses, and the on-site visit tells you.
The 4 RunTru 17 units
Price on quote, after the free on-site estimate.
Which RunTru 17 for which room?
Set the area, the sun, the people and the kitchen: the tool reads ENERGY STAR’s cooling table, takes a guide figure from it, then gives the smallest RunTru 17 that reaches it and the heat Trane publishes for it at −20 °C.
Band 23.2 to 27.9 m² (250 to 300 sq ft): 7,000 BTU/h, no adjustment.
9,000 BTU/h RunTru 17
- Rated cooling9,100 BTU/h
- Heat at −20 °C, room at 20 °C4,300 BTU/h
- Days below −20 °C in Montreal14.3 a year
ENERGY STAR cooling guide figure, not a load calculation: the on-site visit sets the size. ENERGY STAR’s table is for choosing a room air conditioner (8 ft ceiling, 2.44 m); it does not say how much heat the room needs in winter, and the RunTru 17 is not ENERGY STAR certified (list checked October 28, 2026). Rated cooling: Trane sell sheet 26-1061-04 (2024). Heat at −20 °C: submittals M4MHW17…-SUB-1B-EN (August 5, 2022), normal operation per Trane, not certified values. Days below −20 °C: Environment and Climate Change Canada, Montreal-Trudeau, 1981–2010 normals.
The RunTru 17 in figures, size by size
| Trane figure | 9,000 BTU/h | 12,000 BTU/h | 18,000 BTU/h | 24,000 BTU/h |
|---|---|---|---|---|
| Rated cooling / heating | 9,100 / 9,500 BTU/h | 12,000 / 13,000 BTU/h | 17,400 / 18,000 BTU/h | 22,000 / 24,000 BTU/h |
| SEER2 / HSPF2 / EER2 | 17.5 / 8.4 / 10.2 | 16.5 / 8.5 / 8.7 | 16 / 8.2 / 9.5 | 18 / 8.5 / 11.6 |
| Heat at −20 °C, room at 20 °C | 4,300 BTU/h | 6,800 BTU/h | 9,900 BTU/h | 14,200 BTU/h |
| Outdoor sound, at 1 m | 52 dB(A) | 52 dB(A) | 57 dB(A) | 57 dB(A) |
| Indoor, 7 speeds, at 1 m | 26 to 40 dB(A) | 30 to 45 dB(A) | 34 to 47 dB(A) | 37 to 51 dB(A) |
| Line set, liquid – gas | 1/4 – 3/8 in | 1/4 – 3/8 in | 1/4 – 1/2 in | 1/4 – 5/8 in |
| Longest run / highest lift | 15 m / 10 m | 20 m / 10 m | 25 m / 10 m | 25 m / 10 m |
| Minimum circuit ampacity | 9 A | 10 A | 14 A | 15 A |
| Metering | capillary tube | capillary tube | capillary tube | electronic valve |
| Outdoor unit, W × H × D | 732 × 555 × 330 mm, 25.5 kg | 732 × 550 × 330 mm, 25.5 kg | 802 × 555 × 350 mm, 31.5 kg | 958 × 660 × 402 mm, 44 kg |
| The model | See the product | See the product | See the product | See the product |
Sources: Trane sell sheet 26-1061-04 (2024) for rated capacities, SEER2, HSPF2 and EER2; submittals M4MHW17…-SUB-1B-EN (August 5, 2022) and installer’s guide 88-M4MHW17-1B-EN (March 16, 2023) for the rest. The 2022 submittals give other rated capacities for three sizes: 9,000 / 9,400, 11,700 / 12,000 and 17,400 / 19,100 BTU/h. Dimensions and weights converted from Trane’s inches and pounds. For the 24,000, Trane prints 20 A or 30 A as maximum circuit protection depending on the document: the nameplate governs.
The same size in the other series
In the 9,000 BTU/h size, at −20 °C, the RunTru 23 gives 72% more heat than the RunTru 17.
| 9,000 BTU/h | RunTru 17 | RunTru 23 |
|---|---|---|
| Heat at −20 °C, room at 20 °C | 4,300 BTU/h | 7,390 BTU/h |
| Heats down to | −20 °C | −30 °C |
| SEER2 | 17.5 | 23 |
| Metering | capillary tube | electronic valve |
Sources: submittals M4MHW1709A and M4THS2309A-SUB-1B-EN (August 5, 2022), 20 °C column; sell sheets 26-1061-04 and 26-1063-04 (2024); 17 and 23 Series installer’s guides.
What Trane requires when installing the 17 Series
The rules in the 17 Series installer’s guide. A RunTru 17 installation is checked against them.
- The outdoor unit on a base that carries at least four times its weight.
- At least 31.8 mm (1 1/4 in) above the ground or its base, for the drain, level, fastened firmly where winds are strong, and where condensate poses no hazard.
- Unused base pan holes plugged.
- Nitrogen test at 150 psig, then evacuation to 350 microns or below; if the reading keeps rising above 1,500 microns, there is a leak.
- Interconnecting wire at least 14 AWG, 600 V, stranded, no longer than 70 m.
Source: Trane installer’s guide 88-M4MHW17-1B-EN (March 16, 2023).
You already have a RunTru 17
- Filters: a washable one, an air-purifying one and an activated carbon and catechin one; Trane’s submittal calls for cleaning at least once a year.Submittals M4MHW17…-SUB-1B-EN
- Remote: included, with I-Feel, X-Fan and Sleep Mode.Sell sheet 26-1061-04
- Code U4: reversing valve malfunction. That’s a job for a refrigeration technician.Installer’s guides, code list
- Warranty: Trane’s limited parts warranty goes, in most cases, from 5 to 10 years if the unit is registered within 60 days of installation; residential and multi-family use. Labour is not covered by Trane; 6 years on labour, guaranteed by AirGreen, for installations done since October 5, 2026. RunTru registration line: 1-855-956-5685.runtruhvac.com, Warranty page; sell sheet 26-1061-04
Three RunTru 17 details
In cooling, the 24,000 BTU/h RunTru 17 takes 5.28 pints of water an hour out of the air, per Trane, about 2.5 L/h (our conversion).
Submittal M4MHW1724A-SUB-1B-ENThe RunTru 17 also comes as a cooling-only version (M4TCS / M4MCW), with the same line-set sizes.
Sell sheets 26-1061-03 and 26-1061-04The 18,000 and 24,000 accept up to 25 m of line set; every size ships charged for 7.6 m, with a 3 m minimum.
Guide 88-M4MHW17-1B-EN; submittals 1718A and 1724AWhat people ask us about the RunTru 17
Which room is the RunTru 17 right for?
Does it heat below −20 °C?
Do I still need backup heat?
Is there a LogisVert grant on the RunTru 17?
Is it noisy?
Is Wi-Fi built in?
A RunTru 17 in your home, installed by AirGreen
One visit to see the room and measure; the written quote says which RunTru 17 size to choose, and what will heat on nights below −20 °C.
Sources checked on October 28, 2026
- Trane, 17 Series Single Zone sell sheet, 26-1061-04 (2024)
- Trane, 17 Series Single Zone sell sheet, 26-1061-03 (2023), for the cooling-only version
- Trane, submittals M4MHW1709A, 1712A, 1718A and 1724A-SUB-1B-EN (August 5, 2022)
- Trane, 17 Series installer’s guide, 88-M4MHW17-1B-EN (March 16, 2023)
- Trane, RunTru 23 submittal M4THS2309A-SUB-1B-EN (August 5, 2022), for the comparison
- Trane, 23 Series Single Zone sell sheet, 26-1063-04 (2024), for the comparison’s SEER2
- Trane, 23 Series installer’s guide, 88-M4MHW23-1A-EN (November 22, 2021), for the comparison’s −30 °C limit
- RunTru, Warranty page
- ENERGY STAR, Room Air Conditioners, “Properly Sized Room Air Conditioners” table (specification effective October 30, 2023)
- Environment and Climate Change Canada, 1981–2010 climate normals, Montreal-Trudeau (7025250)
- Québec.ca, Mesure du bruit (updated June 16, 2022, in French)
- ENERGY STAR, certified heat pumps (dataset w7cv-9xjt)
- Hydro-Québec, LogisVert residential, conditions page
- Hydro-Québec, LogisVert residential participation guide, version 1.10 (September 15, 2026, in French)