ARCOAIRE N4A4S Performance Central Air Conditioner | 2 Tons - 24000 BTU - R410A
Arcoaire’s 2-ton N4A4S central air conditioner: a single-stage R-410A outdoor unit rated under the SEER2 standard.
Model numberN4A4S24AKANA
514 316-2973 · sales@airgreen.ca
Quick facts
Replace your 2-ton air conditioner with a unit rated under the SEER2 standard
The N4A4S24AKANA in brief
Your 2-ton central air conditioner is reaching the end of the road, while your electric furnace still runs well. Arcoaire’s N4A4S24AKANA is the outdoor unit that takes over: a 24,000 BTU/h nominal size, R-410A refrigerant, a single-stage scroll compressor, a single-speed fan and a filter drier. Its galvanized steel cabinet has a baked-on powder coat finish, and its published sound power is 74 dBA, with or without a sound shield.
It suits cottages, bungalows and plex units that have their own ductwork. It connects to a coil set on the electric furnace or housed in an air handler, sold separately, and leaves the heating as it is.
Why the coil matters as much as the outdoor unit
Arcoaire publishes a range of 13.4 to 16.0 SEER2 for this size. The spread does not come from the outdoor unit but from the matched indoor unit: depending on the coil set on the furnace or air handler, the same air conditioner lands at the bottom or the top of the range. That is why we examine the indoor unit before proposing the outdoor unit. SEER2 is the current rating standard; it does not compare directly with older SEER ratings.
Before ordering
- The panel must be able to take a 208-230 V single-phase circuit protected by a fuse or breaker of 25 A maximum.
- The refrigerant lines connect at 3/8 in (liquid) and 3/4 in (vapor). Arcoaire allows up to 250 ft (76.20 m) of total equivalent length.
- To cool below 55°F (12.8°C), approved low-ambient accessories are required.
- The unit is cooling only: sold alone, it does not qualify for the LogisVert grant.
- Arcoaire states that the N4A4S series is no longer in production: quantities are limited.
The manufacturer’s parts limited warranty is 10 years for the original owner with registration within 90 days of installation, otherwise 5 years; the certificate states that in Quebec, it cannot depend on registration.
Installation, done by AirGreen
AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. We do the free on-site estimate, check the furnace or air handler and the coil, then provide a written quote. Our technicians remove the old unit, set the new one, install the refrigerant lines, connect the circuit and commission the system.
We install in Laval, on the North Shore, in Montreal, Longueuil and on the South Shore.
Ask for a free estimate and receive your written quote. Financing is available to spread out the payment.
Replacing a 2-ton central air conditioner
The N4A4S24AKANA is the outdoor unit of a central air conditioner. It works with a coil set on an electric furnace or housed in an air handler, which cools the air distributed through the ductwork.
- Replacing a 2-ton central air conditioner at the end of its life
- Cottages and bungalows heated by an electric furnace
- Adding air conditioning to an existing air handler
- Plex units with their own ductwork
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Arcoaire states that the N4A4S series is no longer in production: quantities are limited.
- Cooling only. Sold alone, it does not qualify for the LogisVert grant.
- Indoor coil not included; the SEER2 rating achieved depends on that match.
- 208-230 V single-phase circuit: 15.1 A minimum circuit ampacity, 25 A maximum fuse or breaker.
- Lines: up to 250 ft (76.20 m) total equivalent length and 200 ft (61 m) actual length; 80 ft (24.4 m) maximum if the evaporator is above the unit.
- Below 55°F (12.8°C), cooling requires approved low-ambient accessories.
Manufacturer documents
Explore the range
Central air conditionersSee allSame brand
ARCOAIRESee all
Frequently asked questions
Can I keep my current coil?
Not necessarily. The 13.4 to 16.0 SEER2 rating depends on the matched indoor unit, and the coil must suit R-410A and the 2-ton size. We check the existing coil during the free estimate.
What electrical circuit is needed?
A 208-230 V single-phase circuit, with a 15.1 A minimum circuit ampacity and a fuse or breaker of 25 A maximum.
Does it qualify for the LogisVert grant?
No. It is cooling only and, sold alone, it does not qualify for Hydro-Québec’s LogisVert grant.
What warranty does Arcoaire provide?
A 10-year parts limited warranty for the original owner if the unit is registered within 90 days of installation; otherwise, 5 years. Subsequent owners get 5 years. According to the certificate, in Quebec the warranty cannot depend on registration. Labour is not covered by the manufacturer.
Is the model still manufactured?
No. Arcoaire states that the N4A4S series is no longer in production and that quantities are limited. Write to us to confirm availability.
Your 2-ton Arcoaire N4A4S central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.
