ARCOAIRE N4A5S Performance Central Air Conditioner | 2 Tons - 24000 BTU - R410A
The 2-ton Arcoaire N4A5S condensing unit: R-410A central air at 73 dBA sound power, matched with an indoor section.
Model numberN4A5S24AKAWA
514 316-2973 · sales@airgreen.ca
Quick facts
Two tons of central air, at 73 dBA sound power
A condensing unit for lots where everything is close
In a semi-detached house in Montreal or a townhouse in Longueuil, the outdoor unit often ends up a few steps from a window, yours or the neighbour's. The N4A5S24AKAWA, the 2-ton (24,000 BTU/h) outdoor unit of the Arcoaire Performance N4A5S series, publishes a sound power of 73 dBA, with or without sound shield. It is the value Arcoaire puts forward as the lowest in the series.
The principle is that of any split central air conditioner. Outside, the single-stage scroll compressor and the fan reject the heat. Inside, a matched section, a coil on an electric furnace or a fan coil, cools the air your ductwork distributes. The unit runs on R-410A and cools only: it does not heat.
What to know before choosing
Efficiency depends on the match. For this size, the manufacturer's spec sheet publishes a range of 14.3 to 16 SEER2 depending on the indoor unit. There is no certified rating for the condensing unit alone, and, sold alone, it is not eligible for the LogisVert grant. If you are comparing with a central heat pump that would also heat the house, we show you both scenarios side by side.
Another detail we take seriously: two editions of the spec sheet do not give the same electrical values for this size's compressor. Rather than pick one at random, we read the nameplate of the delivered unit before sizing the circuit. The maximum protection is the same in both cases: a 20 A time-delay fuse or breaker, at 208/230 V single phase.
Finally, if you need cooling when it is cool outside, for example for a server room in the basement, the manufacturer requires a low-ambient pressure switch below 55°F (12.8°C) and approved kits to go down to 0°F (-18°C). For ordinary summer use in a home, it is not needed.
Installation by AirGreen, from choosing the location to commissioning
For a unit installed close to the neighbours, the location is half the result. We look with you at the available setback, the nearby windows and the route of the refrigerant piping; the manufacturer allows up to 250 ft of equivalent length, which leaves room to move the unit away from the bedrooms.
Then our technicians set the unit, install or connect the indoor section, run the piping, evacuate, adjust the charge (the unit ships charged for 15 ft of piping), then connect the power and commission the system. AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We work in Laval, on the North Shore, on the South Shore and everywhere in Greater Montreal.
Next step
Book your free on-site estimate: we confirm the 2-ton size, the match and the location, then you receive a written quote. Financing is available.
Quiet central air for homes built close together
The N4A5S24AKAWA is the outdoor unit of a split central air conditioner. It cools the air through a matched indoor section, a coil on an electric furnace or a fan coil; the manufacturer builds its capacity tables with the ESD4X24M14A section.
- Semi-detached houses and townhouses where the outdoor unit sits close to the neighbours
- Duplex or triplex floors served by ductwork
- Single-storey houses heated by an electric furnace
- Replacing a 2-ton condensing unit on an existing installation
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only. Sold alone: not eligible for the LogisVert grant.
- Coil or fan coil not included: the indoor section is chosen from the manufacturer's matches.
- The compressor electrical data differ between two editions of the manufacturer's spec sheet: we read them on the nameplate before sizing the circuit.
- 208/230 V single-phase, 60 Hz power supply; 20 A maximum time-delay fuse or breaker.
- Dimensions and weight are published only on the spec sheet drawing: to be confirmed before choosing the location.
Manufacturer documents
Explore the range
Central air conditionersSee allSame brand
ARCOAIRESee all
Frequently asked questions
Is it loud for the neighbours?
Arcoaire publishes a sound power of 73 dBA for this size, measured under the AHRI 270 test standard. That is sound power, not a pressure measured at a given distance: the location matters as much as the unit, and we choose it with you.
Does the N4A5S24AKAWA heat?
No, it cools only. Heating stays with your electric furnace. Sold alone, it is not eligible for the LogisVert grant.
Which indoor section should it be installed with?
A coil on an electric furnace or a fan coil. The manufacturer's capacity tables use the ESD4X24M14A section; we check the match before ordering.
What SEER2 will I get?
The spec sheet publishes 14.3 to 16 SEER2 for this size. The outdoor unit alone has no certified rating: it all depends on the matched indoor section.
What is the manufacturer's warranty?
According to the ICP limited warranty certificate: parts for 10 years for the original owner if the unit is registered within 90 days of installation, otherwise 5 years. The certificate states that this registration condition does not apply in Quebec. Subsequent owners: 5 years. Labour is not covered by the manufacturer.
A 2-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.