ARCOAIRE N4A5S Performance Central Air Conditioner | 2 Tons - 24000 BTU - R410A

In stock

The 2-ton Arcoaire N4A5S condensing unit: R-410A central air at 73 dBA sound power, matched with an indoor section.

Model numberN4A5S24AKAWA

73 dBAsound power, with or without sound shield
2 tons24,000 BTU/h nominal size
14.3 to 16SEER2 depending on the matched indoor unit
R-410ACooling only208/230 V · single phaseScroll compressor
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberN4A5S24AKAWA
ManufacturerArcoaire
Size2 tons (24,000 BTU/h)
Sound power73 dBA
SEER2 range14.3 to 16, depending on match
Max. protection20 A time-delay fuse or breaker

Two tons of central air, at 73 dBA sound power

A condensing unit for lots where everything is close

In a semi-detached house in Montreal or a townhouse in Longueuil, the outdoor unit often ends up a few steps from a window, yours or the neighbour's. The N4A5S24AKAWA, the 2-ton (24,000 BTU/h) outdoor unit of the Arcoaire Performance N4A5S series, publishes a sound power of 73 dBA, with or without sound shield. It is the value Arcoaire puts forward as the lowest in the series.

The principle is that of any split central air conditioner. Outside, the single-stage scroll compressor and the fan reject the heat. Inside, a matched section, a coil on an electric furnace or a fan coil, cools the air your ductwork distributes. The unit runs on R-410A and cools only: it does not heat.

What to know before choosing

Efficiency depends on the match. For this size, the manufacturer's spec sheet publishes a range of 14.3 to 16 SEER2 depending on the indoor unit. There is no certified rating for the condensing unit alone, and, sold alone, it is not eligible for the LogisVert grant. If you are comparing with a central heat pump that would also heat the house, we show you both scenarios side by side.

Another detail we take seriously: two editions of the spec sheet do not give the same electrical values for this size's compressor. Rather than pick one at random, we read the nameplate of the delivered unit before sizing the circuit. The maximum protection is the same in both cases: a 20 A time-delay fuse or breaker, at 208/230 V single phase.

Finally, if you need cooling when it is cool outside, for example for a server room in the basement, the manufacturer requires a low-ambient pressure switch below 55°F (12.8°C) and approved kits to go down to 0°F (-18°C). For ordinary summer use in a home, it is not needed.

Installation by AirGreen, from choosing the location to commissioning

For a unit installed close to the neighbours, the location is half the result. We look with you at the available setback, the nearby windows and the route of the refrigerant piping; the manufacturer allows up to 250 ft of equivalent length, which leaves room to move the unit away from the bedrooms.

Then our technicians set the unit, install or connect the indoor section, run the piping, evacuate, adjust the charge (the unit ships charged for 15 ft of piping), then connect the power and commission the system. AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We work in Laval, on the North Shore, on the South Shore and everywhere in Greater Montreal.

Next step

Book your free on-site estimate: we confirm the 2-ton size, the match and the location, then you receive a written quote. Financing is available.

01 · What it is for

Quiet central air for homes built close together

The N4A5S24AKAWA is the outdoor unit of a split central air conditioner. It cools the air through a matched indoor section, a coil on an electric furnace or a fan coil; the manufacturer builds its capacity tables with the ESD4X24M14A section.

  • Semi-detached houses and townhouses where the outdoor unit sits close to the neighbours
  • Duplex or triplex floors served by ductwork
  • Single-storey houses heated by an electric furnace
  • Replacing a 2-ton condensing unit on an existing installation
73 dBAThe sound power published for this size, the same with or without sound shield.
14.3 to 16 SEER2The range Arcoaire publishes for the 2-ton size, depending on the matched indoor unit.
5.60 lb factory chargeSet for 15 ft of piping; the charge is then adjusted on site to the actual length.
Compatible with
ESD4X24M14A
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
SeriesN4A5S (Performance 15)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-410A
CompressorScroll, single stage
Efficiency (manufacturer range)14.3 to 16 SEER2 depending on the matched indoor unit
Sound power73 dBA; 73 dBA with sound shield (tested to AHRI 270, not listed with AHRI)
Power supply208/230 V, single phase, 60 Hz (197 to 253 V operating)
Max. time-delay fuse or breaker20 A
Fan motor (FLA)0.6 A
Liquid valve3/8 in
Vapor valve3/4 in
Factory charge5.60 lb (2.54 kg) of R-410A for 15 ft of piping
Piping lengthUp to 250 ft (76.20 m) equivalent; 200 ft (61 m) actual maximum
Elevation difference200 ft (60.96 m) with the outdoor unit higher; 80 ft (24.4 m) with the indoor section higher
Low-ambient coolingDown to 0°F (-18°C) with the approved low-ambient kits
CabinetGalvanized steel, baked-on powder coat; top discharge
Indoor section in capacity tablesESD4X24M14A
Model numberN4A5S24AKAWA
03 · Before installing

What to know before installing

  • Cooling only. Sold alone: not eligible for the LogisVert grant.
  • Coil or fan coil not included: the indoor section is chosen from the manufacturer's matches.
  • The compressor electrical data differ between two editions of the manufacturer's spec sheet: we read them on the nameplate before sizing the circuit.
  • 208/230 V single-phase, 60 Hz power supply; 20 A maximum time-delay fuse or breaker.
  • Dimensions and weight are published only on the spec sheet drawing: to be confirmed before choosing the location.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Is it loud for the neighbours?

Arcoaire publishes a sound power of 73 dBA for this size, measured under the AHRI 270 test standard. That is sound power, not a pressure measured at a given distance: the location matters as much as the unit, and we choose it with you.

Does the N4A5S24AKAWA heat?

No, it cools only. Heating stays with your electric furnace. Sold alone, it is not eligible for the LogisVert grant.

Which indoor section should it be installed with?

A coil on an electric furnace or a fan coil. The manufacturer's capacity tables use the ESD4X24M14A section; we check the match before ordering.

What SEER2 will I get?

The spec sheet publishes 14.3 to 16 SEER2 for this size. The outdoor unit alone has no certified rating: it all depends on the matched indoor section.

What is the manufacturer's warranty?

According to the ICP limited warranty certificate: parts for 10 years for the original owner if the unit is registered within 90 days of installation, otherwise 5 years. The certificate states that this registration condition does not apply in Quebec. Subsequent owners: 5 years. Labour is not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.