ARCOAIRE N4A5S Performance Central Air Conditioner | 5 Tons - 60000 BTU - R410A

In stock

The 5-ton Arcoaire N4A5S condensing unit: the largest size in the series, for cooling very large houses through the ducts.

Model numberN4A5S60AKAWA

5 tons60,000 BTU/h nominal size
13.8 to 15SEER2 depending on the matched indoor unit
73 dBAsound power with sound shield (75 dBA without)
R-410ACooling only208/230 V · single phase50 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberN4A5S60AKAWA
ManufacturerArcoaire
Size5 tons (60,000 BTU/h)
SEER2 range13.8 to 15, depending on match
Minimum circuit ampacity33.4 A
Factory charge10.10 lb (4.58 kg) of R-410A

Five tons of central air, when the house truly calls for it

The largest size in the N4A5S series

The N4A5S60AKAWA is the 5-ton (60,000 BTU/h) outdoor unit of the Arcoaire Performance N4A5S series, its largest size. It targets very large houses cooled through a single duct system: multi-storey properties, houses with extensive glazing, homes where a smaller unit is already not enough. It runs on R-410A, with a single-stage scroll compressor, and it cools only.

Before talking about 5 tons, we check that it is the right choice. An oversized air conditioner cools quickly, shuts off right away and dehumidifies poorly; the house becomes cool but clammy. During the estimate, we look at insulation, window orientation and duct capacity before confirming the size. In some very spread-out houses, two smaller systems, one per floor, give better comfort than a single unit: if that is your case, we will tell you.

The manufacturer's data for this size

Arcoaire publishes a range of 13.8 to 15 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating, and the capacity tables use the EVD4X61M24A section. Sound power is 75 dBA, or 73 dBA with sound shield.

For the electrical side, it needs a 208/230 V single-phase circuit: 33.4 A minimum ampacity and a 50 A maximum time-delay fuse or breaker. On the refrigerant side, the unit ships with 10.10 lb (4.58 kg) of R-410A, a charge set for 15 ft of piping, which our technicians then adjust to the actual length.

This condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. For a house this size, a central heat pump that heats and cools is often worth comparing; we can present both.

What our installation includes

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

  1. Free on-site estimate and confirmation of the size;
  2. Written quote specifying the matched indoor section and the electrical circuit;
  3. Setting the outdoor unit, installing the indoor section;
  4. Refrigerant piping with a 7/8 in vapor valve, evacuation, charge adjustment;
  5. Electrical connection, commissioning and an airflow check at the registers.

The manufacturer allows up to 250 ft of equivalent piping length and 200 ft of actual length, which leaves latitude to place the unit away from a deck or a bedroom. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Let's talk about your house

Ask for a free estimate: we confirm whether 5 tons is the right size, check the panel and the ducts, then give you a written quote. Financing is available.

01 · What it is for

The 5-ton size, for houses that need it

The N4A5S60AKAWA is the 5-ton outdoor unit of the N4A5S series. It is matched with an indoor section of corresponding capacity, a coil on an electric furnace or a fan coil; the manufacturer's spec sheet builds its capacity tables with the EVD4X61M24A section.

  • Very large houses cooled through a single duct system
  • Replacing a 5-ton central air conditioner
  • Multi-storey houses with a large-capacity electric furnace
  • Remote outdoor unit, up to 200 ft of actual piping
60,000 BTU/hThe 5-ton nominal size, the largest in the N4A5S series.
73 dBA with sound shieldThe spec sheet publishes 75 dBA without shield and 73 dBA with shield for this size.
Low ambient down to 0°FWith the manufacturer's approved kits, and a pressure switch required below 55°F outdoors.
Compatible with
EVD4X61M24A
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
SeriesN4A5S (Performance 15)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-410A
CompressorScroll, single stage
Efficiency (manufacturer range)13.8 to 15 SEER2 depending on the matched indoor unit
Sound power75 dBA; 73 dBA with sound shield
Power supply208/230 V, single phase, 60 Hz (197 to 253 V operating)
Minimum circuit ampacity33.4 A
Max. time-delay fuse or breaker50 A
Compressor (RLA / LRA)25.6 A / 150.0 A
Fan motor (FLA)1.40 A
Liquid valve3/8 in
Vapor valve7/8 in
Factory charge10.10 lb (4.58 kg) of R-410A for 15 ft of piping
Piping lengthUp to 250 ft (76.20 m) equivalent; 200 ft (61 m) actual maximum
Elevation difference200 ft (60.96 m) with the outdoor unit higher; 80 ft (24.4 m) with the indoor section higher
Low-ambient coolingDown to 0°F (-18°C) with the approved low-ambient kits
CabinetGalvanized steel, baked-on powder coat; top discharge
Indoor section in capacity tablesEVD4X61M24A
Model numberN4A5S60AKAWA
03 · Before installing

What to know before installing

  • Cooling only. Sold alone: not eligible for the LogisVert grant.
  • 208/230 V single-phase, 60 Hz circuit: 33.4 A minimum ampacity, 50 A maximum time-delay fuse or breaker.
  • The indoor section is not included and must have a corresponding capacity; 7/8 in vapor valve.
  • For this size, the spec sheet publishes 13.8 to 15 SEER2 depending on the match, not the maximum advertised for the series.
  • Dimensions and weight are published only on the spec sheet drawing: to be confirmed before preparing the pad.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Does my house really need 5 tons?

That is the first thing we check. An oversized unit cools quickly but dehumidifies poorly. We assess insulation, windows and ductwork during the free estimate, then recommend the N4A5S size that fits.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 33.4 A minimum ampacity and a 50 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What is the refrigerant charge?

The unit ships with 10.10 lb (4.58 kg) of R-410A, set for 15 ft of piping. Our technicians then adjust the charge to the actual installed length.

What SEER2 will I get?

The spec sheet publishes 13.8 to 15 SEER2 for the 5-ton size, depending on the matched indoor section. The condensing unit alone has no certified rating.

Does this air conditioner heat?

No. It cools only and, sold alone, it is not eligible for the LogisVert grant.

What warranty does the manufacturer offer?

The ICP limited warranty certificate covers parts for 10 years for the original owner with registration within 90 days of installation, otherwise 5 years; it states that this registration condition does not apply in Quebec. Subsequent owners: 5 years. Labour is not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.