Bosch EHK electric heater kits install in the Bosch BVA air handlers used with Bosch IDS central heat pumps. They warm the air already moving through the ducts when the heat pump needs extra heat. Five outputs are available, from 5 to 20 kW, and each heating element is protected by its own circuit breaker.
Five outputs listed by Bosch
The Bosch specifications for the BVA 15 and BVA 2.0 air handlers show which outputs suit each size. The 5, 7.5 and 10 kW kits have a single element and a single circuit; the 15 and 20 kW kits have two.
The kits and their air handlers
- EHK-05B (5 kW), EHK-08B (7.5 kW) and EHK-10B (10 kW): sizes 24, 36, 48 and 60
- EHK-15B (15 kW): sizes 36, 48 and 60
- EHK-20B (20 kW): sizes 48 and 60
Before ordering
Note the full model number on the air handler’s nameplate. The MCA and maximum fuse or breaker size vary with the air handler size and series: they are listed in the Bosch specifications. Bosch also notes that a heat pump system needs a specified airflow, 350 to 450 CFM per ton of cooling.
Installed by AirGreen in Greater Montréal
We install the kit in your Bosch air handler and set up the backup heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a licensed electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the air handler model, the output and the quantity.
Backup heat for the Bosch IDS heat pump
Installed in the BVA air handler, the kit warms the duct air when the heat pump needs extra heat.
- Backup heat for a Bosch IDS central heat pump with a BVA air handler
- Homes heated electrically through ductwork
- Adding backup heat to an existing BVA air handler
- Replacing an EHK kit
5 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Model | Output | Circuits / elements | Protection | BVA 15 air handlers listed by Bosch | BVA 2.0 air handlers listed by Bosch | Part no. | AirGreen code |
|---|---|---|---|---|---|---|---|
| 5 kW – EHK-05B | 5 kW | 1 / 1 | Double-pole circuit breaker | BVA-24WN1-M15, BVA-36WN1-M15, BVA-48WN1-M15, BVA-60WN1-M15 | BVA024, BVA036, BVA048, BVA060 | EHK-05B | AG-AC-13801 |
| 7.5 kW – EHK-08B | 7.5 kW | 1 / 1 | Double-pole circuit breaker | BVA-24WN1-M15, BVA-36WN1-M15, BVA-48WN1-M15, BVA-60WN1-M15 | BVA024, BVA036, BVA048, BVA060 | EHK-08B | AG-AC-13802 |
| 10 kW – EHK-10B | 10 kW | 1 / 1 | Double-pole circuit breaker | BVA-24WN1-M15, BVA-36WN1-M15, BVA-48WN1-M15, BVA-60WN1-M15 | BVA024, BVA036, BVA048, BVA060 | EHK-10B | AG-AC-13803 |
| 15 kW – EHK-15B | 15 kW | 2 / 2 | Double-pole circuit breaker | BVA-36WN1-M15, BVA-48WN1-M15, BVA-60WN1-M15 | BVA036, BVA048, BVA060 | EHK-15B | AG-AC-13804 |
| 20 kW – EHK-20B | 20 kW | 2 / 2 | Double-pole circuit breaker | BVA-48WN1-M15, BVA-60WN1-M15 | BVA048, BVA060 | EHK-20B | AG-AC-13805 |
Bosch lists each kit for specific sizes: check the “Air handlers listed by Bosch” rows of the model you pick.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- EHK-15B needs a size 36 or larger air handler; EHK-20B, size 48 or larger.
- The MCA and maximum fuse or breaker size vary with the air handler size and series: they are listed in the Bosch specifications.
- Bosch notes a heat pump system needs 350 to 450 CFM per ton of cooling.
- The supply circuit is done by a licensed electrician, with the unit powered off.
Manufacturer documents
You may also need
Smart Thermostat BOSCH Connected Control BCC100 | Montreal, Laval, Longueuil, South Shore & North Shore
Smart Thermostat BOSCH Connected Control BCC110 | Montreal, Laval, Longueuil, South Shore & North Shore
Copper Electrical Wire
Fujitsu Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)
Hitachi Port Adapter for airHome RAM-G Multi-Zone
Hitachi PSC-6RAD H-Link Adapter for airHome Indoor UnitOriginal partsSee all
Frequently asked questions
Which kit fits my BVA air handler?
Per the Bosch specifications: 5, 7.5 and 10 kW for sizes 24 to 60, 15 kW for sizes 36 to 60 and 20 kW for sizes 48 and 60. We pick the output from a heating load calculation.
Is EHK-08B an 8 kW kit?
Bosch publishes it as a 7.5 kW kit.
Does it fit an M18-series BVA air handler?
The Bosch M18 air handler specifications we checked list a different kit series. Send us your air handler model number and we confirm before ordering.
Can you install it?
Yes. We fit the kit in the air handler and set up the backup heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.
Genuine backup heat for your Bosch BVA air handler
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.