COMFORTMAKER EAA5X24M14A Evaporator A-Coil | 2 Tons
The Comfortmaker EAA5X24M14A 2-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker B5H3V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X24M14A
514 316-2973 · sales@airgreen.ca
Quick facts
EAA5X24M14A: the 2-ton Comfortmaker coil for narrow furnaces
Some furnaces are slim: the ones in row houses, duplexes and small plex units where the appliance was squeezed into a corner of the mechanical room. The Comfortmaker EAA5X24M14A was designed for that kind of footprint. At 13-1/8 in wide, it is the narrower of the two 2-ton coils in the EAA5X range. It is sold uncased, runs on R-454B refrigerant and connects to a Comfortmaker outdoor unit to form a complete central system.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is what you need to know to decide whether this model is the right one for your home.
What an evaporator coil does in your plenum
The coil is a heat exchanger mounted in the plenum, just above the furnace. The furnace fan pushes the air from your home through its cold tubes. The refrigerant, which evaporates inside, absorbs heat from that air; moisture condenses on the surfaces and runs down to the pan, then out through the drain.
On its own, it does nothing: it needs an outdoor unit, piped to it, that compresses the refrigerant and releases the heat outside. If the outdoor unit is a heat pump, the cycle can reverse in winter and the same coil is then used for heating.
Why width matters as much as tons
When people compare coils, they look at capacity first. For a furnace installation, width is just as decisive. The coil has to fit in the plenum or in a cabinet of the same size; otherwise the air bypasses the heat exchanger and capacity drops.
The EAA5X24M14A measures 13-1/8 in wide by 19-7/8 in high. If your furnace has a different width, we measure on site and, if needed, build an insulated transition. This is routine sheet-metal work, and it is done the same day as the installation.
An A shape, two permitted positions
This is an A-type coil: two sloped faces that meet at the top. Air enters from below and passes through each face. The manufacturer allows two orientations: upflow or downflow vertical. Horizontal installation is prohibited, and we never propose it for this model. If your furnace lies on its side in a crawl space, this model is not the right one.
The metering device is a TXV: a thermostatic expansion valve that doses the refrigerant according to the coil's actual load.
The certified system, step by step
Performance ratings do not belong to the coil alone. They describe a trio: this coil, a specific outdoor unit and an AHRI number that links them. For the EAA5X24M14A, three outdoor units are published.
- B5H3V24*K*AAA (AHRI 218405915): 21,600 BTU/h cooling, 26,600 BTU/h heating at 47 °F, SEER2 19.0, HSPF2 9.5. On paper, this is the best-performing match of the three.
- C5H0V24*K*AAA (AHRI 215666934): 22,800 BTU/h cooling, 24,000 BTU/h heating at 47 °F, SEER2 17.0, HSPF2 9.0.
- C5H8T24*K*AAA (AHRI 216364538): 22,200 BTU/h cooling, 25,000 BTU/h heating at 47 °F, SEER2 15.5, HSPF2 8.0.
Comfortmaker also publishes ENERGY STAR matches under the "EA*5X" family, which groups the EAM5X and EAA5X, with the Q5H9V and N5H9V heat pumps, the SoftSound B5H0V, B5H3V and C5H0V, and the Mainline C5H8T. All of them run on R-454B.
What you gain by switching to a heat pump
If your home is heated with an electric furnace, every kilowatt-hour becomes exactly one kilowatt-hour of heat. A heat pump instead moves heat from outside to inside; in mild weather, it delivers more heat than the electricity it uses. The furnace keeps its role: it takes over when the outdoor temperature falls below the threshold we set with you.
In summer, the same system replaces window units and distributes cool air to every room through your existing ducts. A single thermostat controls both seasons.
Choosing between the 24M14A and its neighbours
Within the series, the choice comes down to three questions: capacity, width and the planned outdoor unit.
- EAA5X24M17A: same 2-ton capacity, but 16-7/16 in wide. It suits wider furnaces. Its match with the B5H3V24*K*AAA is published under a different AHRI number and with a different SEER2; we give you both sheets.
- EAA5X30M14A: same 13-1/8 in width, but 2.5 tons, with the Q5H9V24*K*AAA and N5H9V24*K*AAA units.
- The 3-ton and larger sizes (36M17A, 37M17A, 42M21A, 48M21A, 60M24A, 61M21A) are meant for larger homes and wider furnaces.
In other words, if the furnace is slim and the home is small, this 24M14A is the natural choice. If the furnace is wide, we look at the M17A.
EAA5X24M14A specifications
- Manufacturer: Comfortmaker, EAA5X range.
- Type: uncased evaporator coil.
- Nominal size: 2 tons, or 24,000 BTU/h.
- Refrigerant: R-454B.
- Dimensions W × H × D: 13-1/8 × 19-7/8 in.
- Metering device: TXV.
- Condensate drain: 3/4 in FPT primary and secondary connections.
- Leak detection: generation 2, 5 V refrigerant sensor, factory-installed in the coil. It is not compatible with generation 1 dissipation boards.
- Warranty: 10-year limited parts warranty if registered within 90 days of installation; 5 years without registration.
The leak sensor deserves an explanation. The manufacturer builds this sensor into the coil, and it works with a generation 2 dissipation board. Installation manual IM-EAA5X-05 states that the furnace must be compatible with this generation. We verify this before ordering.
What our installation includes
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. For this system, the work follows this order:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, a custom transition if needed, and sealing the duct joints;
- setting the outdoor unit on a pad or bracket, brazing the piping, nitrogen leak test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and a walk-through at your home.
Before ordering, check these three points
- The coil's refrigerant is R-454B: the outdoor unit must use the same refrigerant and be installed at the same time.
- The published ratings apply only to the certified match specified by Comfortmaker.
- The furnace width and blower capacity must be suitable; we confirm this at the visit.
About the brand
Comfortmaker belongs to International Comfort Products (ICP), a Carrier subsidiary. Its R-454B coils go with the brand's central air conditioners and heat pumps, installed on a furnace or blower cabinet.
LogisVert incentive
The matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and put the application together with you.
Request your estimate
The on-site estimate is free: we measure the furnace, look at the electrical service and give you a written quote for the complete Comfortmaker system. Financing lets you spread the cost of the project.
The heat pump coil for your furnace
The EAA5X24M14A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H3V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H3V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 13-1/8 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.