COMFORTMAKER EAA5X24M17A Evaporator A-Coil | 2 Tons
The Comfortmaker EAA5X24M17A 2-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker B5H3V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X24M17A
514 316-2973 · sales@airgreen.ca
Quick facts
Comfortmaker EAA5X24M17A: 2 tons of capacity in a 16-7/16 in size
You have a small home, but your furnace is not the slim model. It is wider than a row-house unit, and so is the plenum above it. That is exactly the situation the EAA5X24M17A is built for: a 2-ton Comfortmaker evaporator coil, running on R-454B refrigerant, whose 16-7/16 in width fits a roomier plenum.
We install it for customers in Montreal, Laval, Longueuil, the North Shore and the South Shore. This page explains who it is for, what to check and how it compares with the rest of the series.
The three published matches at a glance
A coil has no rating of its own: it is the complete systems that receive one. Comfortmaker publishes three matches for this model, each with its own AHRI number.
- With the B5H3V24*K*AAA heat pump, the AHRI number is 218406027. Capacity is 22,000 BTU/h cooling and 26,200 BTU/h heating at 47 °F, SEER2 20.0, HSPF2 9.5.
- With the C5H0V24*K*AAA, AHRI 215667135: 22,800 BTU/h cooling, 24,000 BTU/h heating at 47 °F, SEER2 16.5, HSPF2 9.0.
- With the C5H8T24*K*AAA, AHRI 216364602: 22,600 BTU/h cooling, 24,600 BTU/h heating at 47 °F, SEER2 17.0, HSPF2 8.1.
These values do not carry over from one coil to another. Even an identical outdoor unit receives a different AHRI number depending on the coil it is matched with. When you compare two quotes, ask for this number: it shows that the trio was tested together.
Why 16-7/16 in changes the installation
A wider coil offers a more open air section. In a plenum of the same width, the air passes straight through without detours and crosses both faces of the coil. In a narrower plenum, we have to reduce or redirect the passage, and that is where the gains of a well-chosen match are lost.
If your furnace does not match this width, the answer is not to force the installation. We build an insulated sheet-metal transition, cut to the size of the existing plenum. The coil then keeps its full surface, and the sealing of the connections is redone properly.
The A-coil and its orientation limits
The EAA5X24M17A is an uncased A-coil, 19-7/8 in high. It is installed in a vertical position, upflow or downflow. The manufacturer prohibits horizontal installation. For a furnace lying on its side under a low floor, you have to consider another product family; we tell you so at the first visit.
Refrigerant metering is handled by a TXV. It adjusts to the thermal load of the moment, which keeps the coil within its operating range when the return air is warmer or cooler.
What exactly is a 2-ton home?
A 2-ton size, or 24,000 BTU/h, suits a compact, well-insulated home: a modest bungalow, a semi-detached house, the ground floor of a plex. The classic trap is choosing bigger "to be safe." An oversized system shuts off quickly, cools the air without time to dry it, and the home stays clammy in muggy weather.
Before we propose this size, we assess the actual load: windows, attic insulation, number of rooms served. If the result calls for more capacity, we move up to the next size without hesitation.
What the heat pump adds in winter
A baseboard heater or an electric furnace converts electricity into heat one for one. With a heat pump, the outdoor unit draws heat from the outside air and transfers it to your coil, which gives it to the air in the duct system. The furnace stays in reserve for the coldest days, based on a threshold we program with you.
This arrangement, called "add-on," keeps the blower, filters and ducts of your current furnace. It avoids tearing anything out.
Comparison with the other EAA5X models
- EAA5X24M14A: same capacity, but 13-1/8 in wide. Preferable if the furnace is narrow.
- EAA5X30M17A: same 16-7/16 in width, but 2.5 tons and different outdoor units (Q5H9V24*K*AAA and N5H9V24*K*AAA).
- EAA5X36M17A and EAA5X37M17A: same width, but 3 tons.
- EAA5X42M21A, EAA5X48M21A, EAA5X61M21A and EAA5X60M24A: larger widths, for more spacious homes.
The M17A therefore stands out for its combination of small capacity and intermediate width. If your furnace measures 16-7/16 in, choosing the M14A would mean a transition; if it is narrow, it is the other way around.
Technical details to keep in mind
- Brand and range: Comfortmaker, EAA5X.
- Category: uncased coil.
- Refrigerant: R-454B.
- Dimensions W × H × D: 16-7/16 × 19-7/8 in.
- Condensate removal: 3/4 in FPT primary and secondary drain connections.
- Safety: factory-mounted 5 V refrigerant sensor (generation 2). It does not work with generation 1 dissipation boards.
- Manufacturer's warranty: 10 years on parts with registration within 90 days of installation, 5 years without registration.
Manual IM-EAA5X-05 calls for a furnace compatible with generation 2 dissipation when the coil is installed uncased. We check this on your unit before any order.
Installation day
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. A typical day:
- in the morning, we measure the furnace, check the blower and look at the electrical panel;
- we set the coil, build the transition if needed and seal the duct joints;
- outside, we install the unit on a pad or bracket, braze the piping, run the nitrogen leak test and pull a vacuum;
- we connect the condensate drain and the thermostat;
- we start up the system, adjust the airflow and explain how it works.
Three checks before buying
- The coil uses R-454B: the outdoor unit must too, and the two are installed together.
- Performance ratings exist only for the certified match.
- The width and blower of your furnace must be suitable; we confirm this at your home.
Who is behind the brand
Comfortmaker is part of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils are matched with the brand's central heat pumps and air conditioners, on a furnace or blower cabinet. ENERGY STAR matches are published under the "EA*5X" family with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T.
LogisVert incentive
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation: we read it from the official list when we prepare your quote, then put the application together with you.
Request your estimate
Book a free estimate visit: we measure the furnace, assess the electrical service and give you a written quote for the complete system. Financing is available to spread out the expense.
The heat pump coil for your furnace
The EAA5X24M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H3V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H3V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 16-7/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.