COMFORTMAKER EAA5X42M21A Evaporator A-Coil | 3.5 Tons
The Comfortmaker EAA5X42M21A 3.5-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker B5H3V36*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X42M21A
514 316-2973 · sales@airgreen.ca
Quick facts
Comfortmaker EAA5X42M21A: 3.5 tons and 19-15/16 in for homes with space
With the EAA5X42M21A, we leave the territory of the small sizes. This Comfortmaker evaporator coil is 3.5 tons (42,000 BTU/h), uncased, running on R-454B refrigerant. Its 19-15/16 in width makes it suited to large furnaces, in homes where the ducts serve many rooms: a good-sized two-storey home, a large single-storey, an enlarged suburban house.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is how it differs from the other coils in the series, and what to examine in your home before choosing it.
More surface, more air to supply
A coil of this size offers more exchange surface, and the system calls for a higher airflow than the small sizes. That airflow is not supplied by the coil: it is the furnace blower that has to push it through.
During our visit, we therefore look at the blower capacity, the plenum size and the condition of the return ducts. A return that is too narrow chokes the system, and the coil ends up cooling poorly. This check comes before any other calculation, because no coil, however well chosen, makes up for a lack of air.
Three certified systems, three profiles
What stands out on this coil's sheet is the variety of published outdoor units. They do not all belong to the same size.
- B5H3V36*K*AAA, SoftSound heat pump, AHRI 218409547: cooling 32,800 BTU/h, heating 34,800 BTU/h at 47 °F, SEER2 20.0, HSPF2 9.5.
- B5H0V36*K*AAA, AHRI 218172257: cooling 33,200 BTU/h, heating 35,800 BTU/h at 47 °F, SEER2 17.5, HSPF2 9.0.
- B5H3V24*K*AAA, AHRI 218406651: cooling 22,600 BTU/h, heating 25,400 BTU/h at 47 °F, SEER2 20.5, HSPF2 9.5.
The third line shows that the same heat pump from the B5H3V family can also be published with this 3.5-ton coil, but with more modest measured capacities than those of the size 36 matches. The right combination is therefore not chosen using only the number of tons written on the coil: it is chosen by comparing the match sheets with the home's actual load. That is precisely the calculation we do with you.
Comfortmaker also publishes ENERGY STAR matches for the "EA*5X" family (EAM5X and EAA5X) with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.
Choosing between the 42M21A and the others
- EAA5X36M17A and EAA5X37M17A: 3 tons and 16-7/16 in. Smaller in capacity and in width.
- EAA5X48M21A: 4 tons, same 19-15/16 in width. For a two-storey home or a large single-storey with a finished basement.
- EAA5X61M21A: 5 tons, also the same width.
- EAA5X60M24A: 5 tons, 23-7/16 in, the widest in the series.
- EAA5X24M14A, 24M17A, 30M14A, 30M17A: 2 tons and 2.5 tons, smaller widths.
The rule of thumb: start from the furnace width, then choose the capacity that suits the home. A furnace 19-15/16 in wide opens the door to this model, to the 4-ton model and to the 61M21A.
For what kind of home, exactly?
Take a large suburban single-storey, with a basement finished as a family room and a wing added a few years ago. The ducts wind a long way, the rooms are many, and the windows are large. A small coil would be overwhelmed here; a 3.5-ton size offers the margin needed, provided the furnace keeps up.
Conversely, in a well-insulated bungalow of modest size, this coil would be too generous. An oversized system short cycles, cools without drying and leaves the air sticky. That is why we never sell a size on square footage alone: we do the load calculation, then discuss it with you, with the numbers in hand.
We will also tell you frankly if the most sensible choice for your home is to go down or up one step in the series.
Shape and installation
The EAA5X42M21A is an uncased A-coil, 19-7/8 in high. It is installed vertically, with upflow or downflow air circulation. Horizontal installation is prohibited. The metering device is a TXV, which lets the coil adapt to the load. Without a factory casing, it is installed in the existing plenum or in a cabinet built on site.
If the furnace has a different width, we build an insulated transition to size.
Features
- Brand and range: Comfortmaker, EAA5X.
- Nominal size: 3.5 tons (42,000 BTU/h).
- Refrigerant: R-454B.
- Dimensions W × H × D: 19-15/16 × 19-7/8 in.
- Condensate drain: 3/4 in FPT primary and secondary connections.
- 5 V refrigerant leak sensor (generation 2), factory-installed; incompatible with generation 1 dissipation boards.
- 10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.
For an uncased coil, manual IM-EAA5X-05 calls for a furnace compatible with generation 2 dissipation.
"Add-on" heat pump: the coil's role
In an "add-on" installation, the furnace keeps its blower, filters and heating elements. The coil fits into the plenum. In summer, the refrigerant evaporates in its tubes and picks up heat from the air; the condensation falls into the pan and goes to the drain. In winter, with a heat pump, the cycle reverses and the coil gives up heat to the air. The furnace steps in when the outdoor temperature falls below the threshold we program with you.
The coil has no rating on its own: SEER2 and HSPF2 describe the certified system, which the AHRI number identifies.
Our work at your home
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, which carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01.
- Measuring the furnace, checking the blower, the plenum and the electrical panel.
- Installing the coil, a transition if needed, sealing the duct connections.
- Setting the outdoor unit, brazed piping, nitrogen leak test and vacuum.
- Connecting the drain and the thermostat.
- Commissioning, airflow adjustment, explanation of how it works.
What to confirm before buying
- The coil and the outdoor unit use R-454B and are installed at the same time.
- The ratings apply to the certified match, and to that match alone.
- The furnace must have the right width and a blower capable of the required airflow.
The Comfortmaker brand
Comfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, on a furnace or blower cabinet.
LogisVert incentive
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We read it from the official list at the quote stage, then prepare the application with you.
Free estimate
Ask for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The EAA5X42M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H3V36*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H3V36*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 19-15/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.