COMFORTMAKER EAA5X30M17A Evaporator A-Coil | 2.5 Tons

In stock

The Comfortmaker EAA5X30M17A 2.5-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEAA5X30M17A

2.5 tons30,000 BTU/h nominal
16-7/16 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpUncasedAHRI 217953812
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEAA5X30M17A
ManufacturerComfortmaker
Size2.5 tons
Width16-7/16 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V24*K*AAA

A two-storey home, a 16-7/16 in furnace: the 2.5-ton Comfortmaker EAA5X30M17A

Picture a suburban two-storey home, on the South Shore or in Laval. Furnace in the basement, ducts running up to the second floor, an old central air conditioner that has seen better days or, worse, three window units buzzing in July. The owner wants a single, quiet system that cools and heats. The Comfortmaker EAA5X30M17A coil is one of the parts that make this possible.

It is a 2.5-ton (30,000 BTU/h) evaporator coil, uncased, running on R-454B refrigerant, with a width of 16-7/16 in. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What an installation day looks like

We arrive early in the day with the coil, the outdoor unit and the piping. Step one: measure the furnace and read the nameplate, check the blower and take a look at the electrical panel. The last two checks matter as much as the coil itself, because they decide the rest of the job.

Next, the coil takes its place in the plenum. If the width does not match exactly, we build an insulated sheet-metal transition. We seal the joints so the air really passes through the coil rather than around it. Outside, the outdoor unit is set on a pad or bracket; the piping is brazed, tested with nitrogen to confirm it is leak-tight, then put under vacuum.

The day ends with connecting the condensate drain and the thermostat, commissioning, adjusting the airflow and a walk-through at your home: what to adjust where, how to change the filter, what to watch for. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01, and AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years.

An intermediate size, for a reason

The 2.5-ton size suits a two-storey home with a well-insulated upper floor or a bungalow with a partly finished basement. It sits between the small and the large sizes of the series. Our role is to confirm it is the right one: a load calculation that looks at the glazing, the insulation and the number of rooms served. If it points to 2 tons or 3 tons, we change models without argument.

The outdoor units that connect to it

For this coil, Comfortmaker publishes two certified matches.

  • Q5H9V24*K*AAA heat pump: AHRI number 217953812. Capacities of 22,200 BTU/h cooling and 23,800 BTU/h heating at 47 °F, SEER2 15.2, HSPF2 9.0.
  • N5H9V24*K*AAA heat pump: AHRI number 217953805. Same capacities and ratings as the previous one.

These numbers are not those of the M14A, even with the same outdoor units: the AHRI number links a specific coil to a specific outdoor unit. By asking any contractor for this number, you can compare quotes on the same basis.

M17A or M14A: a question of width

The two 2.5-ton coils look alike. Same range, same capacity, same outdoor units, same TXV metering device. The difference is the width: 13-1/8 in for the EAA5X30M14A, 16-7/16 in for this one. If your furnace is wide, the M17A avoids having to narrow the plenum. If it is narrow, the M14A will be the more natural fit. A tape measure settles the question.

Elsewhere in the series:

  • EAA5X24M17A: 2 tons, same width as this model.
  • EAA5X36M17A and EAA5X37M17A: 3 tons, also the same width.
  • EAA5X42M21A, EAA5X48M21A, EAA5X61M21A and EAA5X60M24A: larger widths, for bigger homes.

What the coil really does

The coil is a heat exchanger placed in the path of the air. In summer, the refrigerant evaporating in its tubes picks up heat from the home's air, and the moisture condenses before leaving through the drain. In winter, if the outdoor unit is a heat pump, the cycle reverses and the heat brought in from outside is delivered to the building's air by that same exchanger.

The A shape, two sloped faces that meet, offers a large surface in a tight space. The manufacturer allows only the vertical positions, upflow or downflow; horizontal is prohibited.

Why an uncased coil

An "uncased" coil has no metal casing around it. It slides into the furnace plenum, or into a cabinet built on site. For the homeowner, this means less height to find above the unit and an installation that respects the existing space. For us, it means sealing carefully: without a factory casing, it is the quality of the plenum and the joints that ensures all the air passes through the exchanger.

In a basement mechanical room, which is often narrow and crowded by the water heater, the panel and the ducts, this installation flexibility is valuable. We explain before the work what we plan to move, if anything.

The furnace keeps its place

In an "add-on" installation, you keep the blower, filters and ducts of the furnace. It becomes the backup heat: when the outdoor temperature falls below a threshold we program with you, it takes over. For the coldest nights, it is insurance.

The coil has no efficiency rating on its own. The SEER2 and HSPF2 ratings belong to the certified system, and it is these, along with the AHRI number, that count for incentives.

EAA5X30M17A technical data

  • Brand and range: Comfortmaker EAA5X.
  • Category: uncased coil.
  • Nominal capacity: 2.5 tons (30,000 BTU/h).
  • Refrigerant: R-454B.
  • Size W × H × D: 16-7/16 × 19-7/8 in.
  • Water removal: 3/4 in FPT primary and secondary connections.
  • Safety: factory-mounted generation 2, 5 V refrigerant sensor, incompatible with generation 1 dissipation boards.
  • Warranty: 10 years on parts if registered within 90 days of installation; 5 years without registration.

The manufacturer states, in manual IM-EAA5X-05, that the furnace must be compatible with generation 2 dissipation when the coil is installed uncased. The ENERGY STAR match for the "EA*5X" family (EAM5X and EAA5X) is published with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.

What to check before ordering

  • The coil and the outdoor unit share R-454B and are installed together.
  • The published ratings apply to the certified match, not to an improvised assembly.
  • The furnace width and its blower must be suitable, which we confirm at your home.

Brand and manufacturer

Comfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or blower cabinet.

LogisVert incentive

The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it on the official list when we prepare your quote and put the application together with you.

Plan your estimate

Request your free on-site estimate: we measure the furnace, look at the electrical service and give you a written quote for the complete system. Financing lets you spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EAA5X30M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Certified systemMatched with the Q5H9V24*K*AAA, the system carries AHRI 217953812.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEAA5X30M17A
TypeUncased evaporator coil
LineEAA5X
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Dimensions W × H × D16-7/16 × 19-7/8 in
Matched outdoor unitQ5H9V24*K*AAA, N5H9V24*K*AAA
System AHRI number217953812, 217953805
System SEER2 / HSPF215.2 / 9.0
Model numberEAA5X30M17A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 16-7/16 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.