COMFORTMAKER EAA5X36M17A Evaporator A-Coil | 3 Tons
The Comfortmaker EAA5X36M17A 3-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X36M17A
514 316-2973 · sales@airgreen.ca
Quick facts
Comfortmaker's EAA5X36M17A: 3 tons for the typical bungalow and two-storey home
If you had to draw the average home in Greater Montreal, you would find a furnace in the basement, a network of ducts reaching every room and, in summer, an old central air conditioner or a few window units. That is the picture the Comfortmaker EAA5X36M17A evaporator coil answers: 3 tons, or 36,000 BTU/h, on R-454B refrigerant, 16-7/16 in wide.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, wherever an existing furnace can become the heart of a modern central system.
A twin in the series: the EAA5X37M17A
Here is a detail that surprises people: the series has two 3-ton coils of the same width, the 36M17A (this page) and the 37M17A. Same 16-7/16 × 19-7/8 in dimensions, same refrigerant, same TXV metering device, same planned outdoor units, Q5H9V24*K*AAA and N5H9V24*K*AAA.
What changes are the AHRI numbers and the published ratings for each match. The two models are not interchangeable in an incentive application or a quote: the one on your contract must match the coil actually installed. We check the model number on the box before we start.
The two matches for the 36M17A
- With the Q5H9V24*K*AAA heat pump: AHRI 217953828. Cooling of 22,200 BTU/h, heating of 24,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.5.
- With the N5H9V24*K*AAA heat pump: AHRI 217953821, same capacities and same ratings.
Comfortmaker also ties this coil to the ENERGY STAR "EA*5X" family (EAM5X and EAA5X), which also includes the SoftSound B5H0V, B5H3V and C5H0V heat pumps and the Mainline C5H8T, all on R-454B.
Why 3 tons?
Three tons fits a large share of the bungalows and two-storey homes in the region. The size is generous enough to keep up on hot days, without excess. You don't buy bigger as a precaution: an oversized system starts and stops constantly, and it dries the air poorly.
Our method stays the same: an on-site load calculation before any proposal. If the home needs less, we steer you toward 2.5 tons; if it needs more, toward 3.5 tons.
Anatomy of the coil
The 36M17A is an A-coil: two sloped planes joined at the top, which expose a large surface to the furnace air in a compact volume. It is supplied uncased. It is installed vertically, upflow or downflow; horizontal is prohibited by the manufacturer.
The TXV regulates the refrigerant flow admitted into the coil. As for the drain, it has 3/4 in FPT primary and secondary connections: the first carries away everyday condensation, the second serves as a safeguard.
Five lines of features
- Nominal capacity: 3 tons, 36,000 BTU/h.
- Refrigerant: R-454B.
- Width, height: 16-7/16 × 19-7/8 in.
- Generation 2, 5 V leak sensor, factory-installed; not compatible with generation 1 dissipation boards.
- 10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.
For an uncased coil, manual IM-EAA5X-05 requires a furnace compatible with generation 2 dissipation.
The furnace: repurposed, not replaced
With a heat pump, the furnace keeps its blower, filters and ducts. It falls back to a backup role for the coldest nights, based on the threshold we program with you. Efficiency ratings belong to the certified system and not to the coil taken alone, and the AHRI number is what lets you compare two quotes honestly.
Switching from direct electric heating to a heat pump also means gaining air conditioning. One outdoor unit, one thermostat, cool air in every room.
What the seasons change in a 3-ton home
In July, a home of this size needs cool air in the back bedroom as much as in the living room. The coil does its work in two steps: it cools the air, then dries it, because water vapour condenses on its fins. This dehumidification is half of the comfort; a home at 24 degrees that is clammy feels hotter than a slightly warmer, dry one.
In January, if the outdoor unit is a heat pump, the direction of the cycle changes. The indoor coil becomes the surface through which heat enters the home's air. During the harshest periods, the furnace takes over. You have nothing to do: the thermostat manages the switch from one to the other.
Questions we are often asked
Do I need to replace the furnace? No, as long as it is in good condition, compatible with generation 2 dissipation and fitted with a suitable blower. We check this at the visit.
Can I keep my old air conditioner? Generally not: the coil runs on R-454B and is matched with the outdoor unit specified by the manufacturer. We install the two together.
Are my ducts sufficient? This is one of the points we examine: the condition of the return ducts, the size of the plenum and the blower capacity affect the result as much as the coil.
How we proceed
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
- Measuring the furnace, checking the blower and the electrical panel.
- Installing the coil in the plenum, building a transition if needed, sealing the duct joints.
- Outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum.
- Connecting the condensate drain and the thermostat.
- Commissioning, airflow adjustment and a walk-through at your home.
Choosing the 36M17A over another model
- Same width, 2 tons: EAA5X24M17A.
- Same width, 2.5 tons: EAA5X30M17A.
- Same width, same 3-ton size: EAA5X37M17A, whose match ratings are published under different AHRI numbers.
- Narrower furnace (13-1/8 in): the series has no 3-ton model at this width; we then look at the EAA5X24M14A and EAA5X30M14A, or adapt the plenum.
- Larger: EAA5X42M21A (3.5 tons), EAA5X48M21A (4 tons), EAA5X60M24A and EAA5X61M21A (5 tons).
To confirm before buying
- The coil's R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
- The published ratings apply to the certified match.
- The furnace must have the right width and blower, which we confirm at the visit.
Comfortmaker in brief
Comfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils are matched with the brand's central heat pumps and air conditioners, on a furnace or blower cabinet.
LogisVert incentive
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We consult the official list at the quote stage and prepare the application with you.
Get your estimate
Ask for your free on-site estimate: we measure the furnace, check the electrical service and provide a written quote for the complete Comfortmaker system. Financing helps spread out the cost of the project.
The heat pump coil for your furnace
The EAA5X36M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 16-7/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.