COMFORTMAKER EAA5X60M24A Evaporator A-Coil | 5 Tons
The Comfortmaker EAA5X60M24A 5-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker Q5H9V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X60M24A
514 316-2973 · sales@airgreen.ca
Quick facts
EAA5X60M24A: the widest Comfortmaker coil, 5 tons and 23-7/16 in
In the EAA5X series, one coil stands out for its dimensions: the EAA5X60M24A. It offers 5 tons of nominal capacity (60,000 BTU/h) in a body 23-7/16 in wide by 19-7/8 in high, which makes it the widest in the family. It is an A-type, uncased coil, and it runs on R-454B refrigerant.
This is a coil for the large furnaces of large homes. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Why width is the first criterion
For a 5-ton, two sizes exist in the series: this one, 23-7/16 in wide, and the EAA5X61M21A, narrower at 19-15/16 in. They offer the same nominal capacity; what separates them is the furnace they are installed on. So we choose first by measuring the plenum, then we check that the rest of the system keeps up.
A coil installed on a narrower plenum requires a transition. We build it from insulated sheet metal, but the result is better when the widths match. That is why we measure before ordering, never after.
What Comfortmaker publishes for this coil
Two matches are published, with size 48 heat pumps:
- Q5H9V48*K*AAA: AHRI number 217954416. Cooling of 44,500 BTU/h, heating of 48,500 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0.
- N5H9V48*K*AAA: AHRI number 217954411, with the same capacities and the same ratings.
A coil is only half of a system: the rating depends on the whole. We go over these numbers with you, with no promise that isn't on the sheet, and we give you both match sheets if you want to compare them.
Two checks specific to large capacities
The electrical service. The outdoor unit requires a dedicated circuit, and the panel must be able to accommodate it. In an older home, where the panel has already been stretched, this is sometimes the real subject of the project. We look at it at the first visit, before talking about price.
Air distribution. The system must reach its nominal airflow, and that depends on the blower, the plenum and the return ducts. A blower that is too weak leaves the coil too cold and the home unevenly cooled.
We also tell you frankly if two smaller systems would serve your home better. Five tons is the largest common residential size; it is not always the right answer, even for a large home.
A large home, a large duct network
A wide coil is only worth the air you give it. In a home enlarged over the years, it is not unusual for ducts to have been extended without anyone recalculating the network: insufficient return air, an original plenum that is too small, blocked registers. Before installing a 5-ton, we review these elements, because the coil cannot make up for a network that chokes.
Sometimes the solution is to add a return air or rework the plenum, which is done during the installation. We tell you at the quote stage and not on the day of the job.
Comparing with the rest of the series
- EAA5X61M21A: same 5-ton capacity, but 19-15/16 in wide. Published ratings slightly different for the match.
- EAA5X48M21A: 4 tons, 19-15/16 in.
- EAA5X42M21A: 3.5 tons, 19-15/16 in.
- EAA5X36M17A and EAA5X37M17A: 3 tons, 16-7/16 in.
- EAA5X30M14A, 30M17A, 24M14A, 24M17A: 2.5-ton and 2-ton sizes, for more modest homes.
The shape, the positions and the metering device
The coil is an A-coil: two sloped faces that meet at the top. Air enters at the centre and passes through each face. The manufacturer allows the vertical position, upflow or downflow, and prohibits horizontal. The metering device is a TXV. Condensate water leaves through 3/4 in FPT drain connections, primary and secondary.
Since there is no factory cabinet, the coil is installed in the existing plenum or in a cabinet built on site, which leaves some freedom when space is tight.
Manufacturer's sheet
- Comfortmaker, EAA5X range, uncased evaporator coil.
- Nominal size: 5 tons (60,000 BTU/h).
- Refrigerant: R-454B.
- Dimensions W × H × D: 23-7/16 × 19-7/8 in.
- Leak detection by a generation 2, 5 V refrigerant sensor, factory-installed; it does not work with generation 1 dissipation boards.
- 10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.
Manual IM-EAA5X-05 states that the furnace must be compatible with generation 2 dissipation. The ENERGY STAR matches published for the "EA*5X" families (EAM5X and EAA5X) also include the SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.
The furnace's role stays whole
With a heat pump, the furnace keeps its blower, filters and ducts. It becomes the backup heat for the coldest periods, based on a threshold we program with you. In summer, the system cools every floor and dries the air. A single thermostat controls both seasons, and a single outdoor unit replaces all the window units.
Note that the coil has no efficiency rating of its own. The SEER2 and HSPF2 ratings belong to the matched system, and the AHRI number is what lets you compare two quotes and file an incentive application.
How the job unfolds
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, and its refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
- Measuring the furnace, checking the blower, the plenum and the electrical panel.
- Installing the coil, custom transition if needed, sealing the duct connections.
- Installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum.
- Connecting the condensate drain and the thermostat.
- Commissioning, airflow adjustment and explanation of how it works.
To confirm before buying
- Coil and outdoor unit use the same refrigerant, R-454B, and are installed together.
- The published ratings apply to the certified match only.
- The furnace must offer the right width and blower; we confirm this at the visit.
Comfortmaker
Comfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or blower cabinet.
LogisVert incentive
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it on the official list at the quote stage and prepare the application with you.
Request your estimate
Ask for your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The EAA5X60M24A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V48*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 23-7/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
