COMFORTMAKER EAA5X37M17A Evaporator A-Coil | 3 Tons
The Comfortmaker EAA5X37M17A 3-ton R-454B uncased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAA5X37M17A
514 316-2973 · sales@airgreen.ca
Quick facts
EAA5X37M17A: reading the ratings of a 3-ton Comfortmaker coil
When two quotes for a central heat pump land on the table, they often look like lists of numbers that make no sense: SEER2, HSPF2, BTU/h, AHRI number. The Comfortmaker EAA5X37M17A evaporator coil is a good example for learning to read them. It is a 3-ton (36,000 BTU/h) model, uncased, running on R-454B refrigerant, 16-7/16 in wide, whose published matches show, according to the sheet, SEER2 16.0, HSPF2 9.5.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
A coil without ratings, a system with ratings
First point to remember: the coil alone has no efficiency rating. Ratings belong to a system tested as a whole: this coil, a given outdoor unit, and the AHRI number that certifies the trio. Change one element and the numbers change. That is why we never promise a rating without naming the outdoor unit that goes with it.
The two systems for the 37M17A
- Q5H9V24*K*AAA heat pump, AHRI number 217953700: 22,800 BTU/h cooling, 24,800 BTU/h heating at 47 °F, SEER2 16.0, HSPF2 9.5.
- N5H9V24*K*AAA heat pump, AHRI number 217953693: same capacities and same ratings.
Quick reading: SEER2 measures cooling efficiency over a season, HSPF2 measures heating efficiency. The higher these numbers, the less the system uses for the same result. The 47 °F figure is the outdoor temperature at which the heating capacity is published; it says nothing about what happens at lower temperatures.
And the EAA5X36M17A, then?
The 36M17A is a coil of the same size: 3 tons, 16-7/16 in wide, same outdoor units, same 16-7/16 × 19-7/8 in dimensions. What sets them apart on paper are the AHRI numbers and the published ratings of their matches. If the quote in your hands cites one or the other, make sure the model number and the AHRI number agree: a mix-up skews any comparison. We check them before ordering.
The other models in the series:
- EAA5X24M17A and EAA5X30M17A: same width, smaller capacities (2 tons and 2.5 tons).
- EAA5X42M21A (3.5 tons), EAA5X48M21A (4 tons): 19-15/16 in wide.
- EAA5X61M21A (5 tons, 19-15/16 in) and EAA5X60M24A (5 tons, 23-7/16 in).
- EAA5X24M14A and EAA5X30M14A: 13-1/8 in, for narrow furnaces.
Shape, orientation and metering device
This is an A-coil. Its two sloped faces form a roof over the condensate pan. Furnace air passes through it from bottom to top or from top to bottom, depending on whether the furnace is upflow or downflow: these are the only two positions the manufacturer allows. Horizontal installation is prohibited.
The metering device is a TXV. The drain, with its 3/4 in FPT primary and secondary connections, carries away the water the coil produces in summer. We connect both, and we test the flow at commissioning.
Manufacturer specifications
- Comfortmaker, EAA5X range, uncased coil.
- Nominal size of 3 tons (36,000 BTU/h), R-454B refrigerant.
- Dimensions W × H × D of 16-7/16 × 19-7/8 in.
- Generation 2, 5 V refrigerant sensor, factory-installed, not compatible with generation 1 dissipation boards.
- 10-year limited parts warranty with registration within 90 days of installation; 5 years without registration.
Manual IM-EAA5X-05 states that an uncased coil requires a furnace compatible with generation 2 dissipation. For ENERGY STAR matches, Comfortmaker uses the "EA*5X" family (EAM5X and EAA5X), with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T, all on R-454B.
Why 3 tons suits so many homes
Bungalows and two-storey homes in the region often have a furnace in the basement, a full duct network and a humid summer. At 3 tons, the system has the capacity to hold the temperature in this type of home, without short cycling. We always confirm it with a load calculation: a very well-insulated home may need less, an enlarged or heavily glazed home may need more.
The furnace stays in place with its blower, filters and ducts. If the outdoor unit is a heat pump, the furnace serves as backup heat when it is very cold, based on a threshold we program with you.
Three common mistakes when comparing ratings
Comparing coils with each other instead of comparing systems. Two quotes that cite the same outdoor unit may describe different matches, with different ratings. Always ask for the full AHRI number.
Confusing nominal capacity with published capacity. The 3-ton size designates the size of the family; the match sheet gives the capacity actually measured in cooling and in heating at 47 °F, and it can differ.
Forgetting the furnace. The best rating is of no use if the blower does not supply the airflow the system requires. That is why an on-site visit comes before any firm quote: we test what the spec sheet cannot say about your home.
When you switch from electric heating to a heat pump
An electric furnace or baseboard converts electricity into heat one for one. A heat pump moves heat that is already present in the outdoor air; that is why its efficiency exceeds direct heating in mild weather, and why that efficiency drops when it is very cold. This is why the furnace stays connected as backup. You keep the security of a second heating mode, without giving up the comfort of cool air in summer.
The job, from start to finish
AirGreen is a family-owned heating and cooling company, active in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
- Taking the furnace dimensions, checking the blower and the electrical panel.
- Installing the coil in the plenum, with a custom transition if needed; sealing the duct connections.
- Installing the outdoor unit, brazed piping, nitrogen test, vacuum.
- Connecting the condensate drain and the thermostat.
- Commissioning, airflow adjustment and explanations.
Before you sign
- The coil and the outdoor unit must use the same refrigerant, R-454B, and be installed together.
- The ratings apply to the certified match and to that match alone.
- The furnace width and blower capacity must be suitable; we confirm this at your home.
The brand
Comfortmaker is a brand of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B coils go with its central heat pumps and air conditioners, on a furnace or blower cabinet.
LogisVert incentive
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it on the official list at the quote stage and prepare the application with you.
Request your estimate
The on-site estimate is free. We measure the furnace, check the electrical service and give you a written quote for the complete system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The EAA5X37M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 16-7/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.