Comfortmaker EVD5X19S17B coil: 1.5 tons in a 17-1/2 in cabinet
"My furnace is wider than what I was shown online. Will it still work?" That is the question we hear most often when a homeowner starts looking for an evaporator coil. For the Comfortmaker EVD5X19S17B, the answer depends on one number: 17-1/2 in, the width of its cabinet.
This V-coil, with a nominal capacity of 1.5 tons (18,000 BTU/h), is designed to be added to a furnace or blower cabinet in a small or medium-sized house. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Width comes first
A coil with a cabinet sits on the furnace like a lid. If it is narrower than the furnace, the gap has to be closed; if it is wider, the air and the heat do not reach the right place. Furnaces are made in several widths, and the one in your house is not necessarily the most common.
At 17-1/2 in, the EVD5X19S17B is aimed at furnaces a little wider than the compact models in the series. If your unit is narrower or wider, we build an insulated transition on site. It is routine sheet-metal work in our trade.
What this model does, plainly
Connected to a Comfortmaker outdoor unit of the same capacity, it cools the air of the house in summer. Paired with a heat pump, it also heats in winter, through the same ducts. You do not add a new air distribution system: you make use of the one you already have.
The expansion valve is a TXV. This device adjusts the flow of refrigerant according to the actual load on the coil, which avoids flooding the tubes when the air is lukewarm and starving them when it is very hot.
Its narrow twin and the higher capacities
In the EVD5X series, the only other 1.5-ton coil is the EVD5X18S14B, which is narrower at 14-3/16 in. Everything else is identical on the points we compare: R-454B refrigerant, TXV expansion valve, cased. The choice between the two is therefore settled with a tape measure, in front of your furnace.
If your home needs more capacity, the series then offers 2 tons (EVD5X24S14B, EVD5X24S17B, EVD5X25S14B and EVD5X25S17B), 2.5 tons (EVD5X30S14B, EVD5X30S17B and EVD5X31S17B) and 3 tons (EVD5X36S17B, EVD5X36S21B and EVD5X37S21B). A jump in capacity is not a gift: it has to match the calculated load of the house.
How the installation goes, step by step
- We measure the furnace, check the blower and look at the electrical panel.
- We install the coil in the plenum, with a transition if needed, and seal the joints.
- The outdoor unit is installed on a pad or bracket, and the piping is brazed, then tested with nitrogen and evacuated.
- We connect the condensate drain and the thermostat.
- Commissioning ends with the airflow adjustment and a demonstration at your home.
Specifications
- Model: EVD5X19S17B, Comfortmaker EVD5X series;
- Cased evaporator coil, vertical positions (upflow or downflow);
- Nominal capacity of 1.5 tons, or 18,000 BTU/h;
- R-454B refrigerant, TXV expansion valve;
- Width of 17-1/2 in;
- 3/8 in liquid connection, 5/8 in suction connection;
- Sloped PBT condensate pan with 3 sealed plugs;
- Factory-installed A2L leak sensor, without a dissipation board: a furnace with built-in dissipation or the ACAENCDIS01A kit is required;
- Limited warranty of 10 years on parts, provided the unit is registered within 90 days after installation; without registration, the period is 5 years.
The certified match and the AHRI number
The coil has no efficiency rating on its own. The complete system and its AHRI number carry the SEER2, EER2 and HSPF2 values. We confirm this number before ordering, so that the figures promised are the ones you will get.
Also note that, according to Comfortmaker, serial numbers ending in B (EVD5X..S..B) are not yet listed in ENERGY STAR. Only the numbers ending in A (EVD5X..M..A) are certified there, with the Q5H9V and N5H9V heat pumps. The AHRI directory remains the reference for approved matches.
An add-on system, a furnace that keeps working
In an add-on setup, the furnace keeps its blower, its filters and its heating elements. The coil is placed in the path of the air. When it is very cold outside, the furnace takes over below the threshold that we set together.
For a homeowner who heats with electricity, it is often a chance to bring consumption down: in mild weather, a heat pump delivers two to three times more heat than the electrical energy it uses.
R-454B and the leak sensor
This refrigerant is classified A2L. The coil therefore comes with a factory-installed sensor, but without a dissipation board. If your furnace does not include this dissipation, the ACAENCDIS01A kit solves the problem. We check it at the visit, not on delivery day.
Family-owned, RBQ licensed
AirGreen has been a heating and cooling company in Montreal for more than fifteen years, and every refrigeration, ventilation or electrical job is carried out under our RBQ licence 5645-9605-01. Comfortmaker, for its part, is a brand of International Comfort Products (ICP), a subsidiary of Carrier.
To check before you order
- Same refrigerant, R-454B, for the coil and the outdoor unit, installed together.
- Efficiency ratings valid only for the certified match.
- A furnace with a suitable width and blower, confirmed during our visit.
Incentives
Hydro-Québec programs assess the complete system, not the coil alone. We consult the official list at the time of the quote, according to the installation date, and tell you what applies.
Cooling without wall units: what it changes day to day
In a house where people sleep upstairs and live on the ground floor, a single unit in the middle of the house rarely deals with the heat in every room. Air pushed through the existing ducts and cooled by the coil circulates wherever a vent is installed. The back bedrooms get the same comfort as the living room.
The furnace filter then works all year. Because the air goes through it more often, we recommend checking it regularly; a clogged filter reduces airflow and tires both the blower and the coil.
Condensate: a detail not to neglect
When the coil cools the air, it removes water from it. The water is collected in a sloped PBT pan fitted with 3 sealed plugs, then directed to the drain. The slope keeps the water from standing; the plugs make it possible to adapt the outlet to the furnace configuration.
During installation, we connect the drain to a suitable discharge point and check that the water flows. It is a modest step, but it is the one that protects the ceiling or floor under the furnace.
If your furnace is narrower or wider
A house does not always have the furnace that the catalogue assumes. Some were installed long ago, others were moved during a renovation. We do not impose a furnace model: we start from what is in your home, we measure, and we adapt the connection with an insulated transition built on site.
This approach avoids replacing a furnace in good condition simply so that it can take a coil. It also keeps the cabinet well supported and the joints well sealed, two conditions for quiet operation.
What you receive at the end of the job
Once commissioning is complete, we go over the thermostat with you: what temperature to aim for in summer, how to set the changeover threshold to the furnace in winter, and where to find the filter. You leave with a system that you know how to use, not just a unit that has been installed.
Estimate and financing
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EVD5X19S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.