COMFORTMAKER EVD5X36S21B Evaporator V-Coil | 3 Tons
The Comfortmaker EVD5X36S21B 3-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVD5X36S21B
514 316-2973 · sales@airgreen.ca
Quick facts
The Comfortmaker EVD5X36S21B coil: 3 tons, 21 in wide cabinet
At 21 in wide, the EVD5X36S21B is one of the two widest coils in Comfortmaker’s EVD5X series. It combines this large footprint with a nominal capacity of 3 tons (36,000 BTU/h), R-454B refrigerant and a TXV expansion valve. It is a cased V-type evaporator coil designed to sit on a furnace or a blower cabinet.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Why the 21 in width matters
High-capacity furnaces are often wider than the compact models. Their plenum has a matching opening, and a 21 in cabinet fits there without a transition. Placing a narrower cabinet on a large furnace means closing the gap, and every extra joint is a place where air can leak.
This model therefore suits homes whose furnace is itself wide. If yours is not, we build an insulated transition on site, but we will first steer you toward the cabinet that matches best.
The check that comes before everything else
Before going further, we take three measurements: the inside width of the plenum, the height available above or below the furnace, and the distance between the furnace and the planned location of the outdoor unit. The last one determines the length of piping to braze. The first two decide whether the 21 in cabinet can fit without difficulty.
Choosing among three 3-ton coils
The EVD5X36S17B is 17-1/2 in wide: it is the narrowest of the three. The EVD5X37S21B shares the 21 in width with this one, and on our listings, its published characteristics are identical. Between these two twins, availability and the certified match decide.
Below 3 tons, the 2.5-ton coils in the series are 14-3/16 in wide (EVD5X30S14B) or 17-1/2 in wide (EVD5X30S17B and EVD5X31S17B). None is as wide as this one.
The specifications in detail
- Brand and series: Comfortmaker EVD5X;
- Cased evaporator coil;
- Nominal capacity: 3 tons (36,000 BTU/h);
- Width: 21 in;
- R-454B refrigerant, TXV expansion valve;
- Vertical positions, upflow or downflow;
- Connections of 3/8 in (liquid) and 3/4 in (suction);
- Sloped PBT pan with 3 sealed plugs;
- Factory-installed A2L sensor, without a dissipation board: the furnace must offer built-in dissipation, or the ACAENCDIS01A kit is needed;
- Limited warranty of 10 years on parts with registration within 90 days of installation, 5 years without registration.
Air and the blower for a large system
A coil of this capacity only works well if the blower brings it the right airflow. We check the blower, the cleanliness of the filter and the condition of the accessible ducts. Insufficient airflow shows up as a frosted coil, poorly cooled air or a clammy house. It is better to fix the cause before installing than to try to compensate afterward.
Add-on heat pump: the furnace takes a rest
With a heat pump, this coil makes it possible to heat through the current ducts. The furnace keeps its blower and its heating elements, but only starts below the outdoor temperature threshold that we set together. In mild weather, the heat pump supplies two to three times more heat than the electricity it consumes.
In summer, the same coil cools the air and removes humidity, which flows to the drain.
Reading the efficiency ratings without error
The coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values belong to the matched system and its AHRI number. We confirm this number in the AHRI directory before ordering. Comfortmaker states that serial numbers ending in B (EVD5X..S..B) are not yet in ENERGY STAR, whereas those ending in A (EVD5X..M..A) are, with the Q5H9V and N5H9V heat pumps.
Our steps
- measuring the furnace, the blower and the electrical panel;
- installing the coil in the plenum, sealed joints, transition if needed;
- outdoor unit on a pad or bracket, brazed piping, nitrogen, vacuum;
- condensate drain and thermostat;
- commissioning, airflow adjustment, demonstration.
AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Comfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier.
What to confirm before ordering
- Same refrigerant, R-454B, for the coil and the outdoor unit.
- Ratings valid for the certified match.
- A furnace wide enough, with a suitable blower and dissipation.
The homes concerned
These are generally large houses, large cottages or forced-air buildings that need a lot of air and whose furnace was chosen accordingly. In the Montreal, Laval and Longueuil area and on both shores, we come across them in a wide variety of neighbourhoods. Every house has its constraints, and we adapt to them.
Sometimes a house looks big but its load calculation points to a more modest size, especially if the insulation has been redone. Conversely, a medium-sized house that is heavily glazed may need more capacity. Hence the value of calculating rather than assuming.
The plenum, the cabinet and airtightness
An insulated 21 in cabinet must sit solidly on the furnace, with sealed joints all around. We use an appropriate sealant and check that no air escapes the coil. A joint that lets uncooled air through reduces performance and can cause condensation on the outside of the cabinet.
This attention to detail is what separates a correct installation from a lasting one.
The drain and protecting the floor
The sloped PBT pan, with 3 sealed plugs, collects the condensation water. We connect the drain, pour in water to check the flow and show you where to check it later. A poorly connected pan is the most common cause of water damage after a coil is installed.
Warranty and registration
The limited 10-year parts warranty requires registration within 90 days after installation. Without that step, the warranty is 5 years. We remind you at the end of the job.
One last piece of advice
If two quotes propose different coils for the same furnace, ask each one to justify its width and capacity. A precise answer, with measurements, is a good sign. A vague answer is a bad one. We always strive to give the first.
Incentives
Hydro-Québec programs apply to the complete system. We consult the official list at the quote, according to the installation date, then tell you what applies.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EVD5X36S21B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.