COMFORTMAKER EVD5X36S17B Evaporator V-Coil | 3 Tons

In stock

The Comfortmaker EVD5X36S17B 3-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X36S17B

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X36S17B
ManufacturerComfortmaker
Size3 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV

EVD5X36S17B: 3 tons at 17-1/2 in, the Comfortmaker coil for a large forced-air home

The bigger the house, the more heat the system has to move, and the more every detail of the installation counts. The Comfortmaker EVD5X36S17B evaporator coil offers 3 tons nominal (36,000 BTU/h) in a cabinet 17-1/2 in wide. It is a cased V-coil from the EVD5X series and runs on R-454B refrigerant.

AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, in two-storey houses, enlarged cottages and large bungalows.

When we talk about 3 tons

Three tons is the highest capacity in the EVD5X series. It is meant for homes whose load calculation exceeds what 2.5 tons can handle: large floor areas, high ceilings, a lot of glazing or average insulation. We recommend it only after a calculation, not on the basis of floor area.

Erring on the high side is no wiser than erring on the low side. A system that is too big runs short cycles, leaves the air clammy and puts more frequent strain on its components.

The ducts, first judge of capacity

A large capacity needs a large airflow. If the ducts in the house are narrow, poorly sealed or too long, the air does not arrive in sufficient quantity in the distant rooms. We therefore inspect the accessible ducts, the blower and the plenum. A 3-ton system connected to an undersized network will disappoint, whatever the quality of the coil.

When necessary, we recommend corrections: sealing, balancing or replacing a section. The choice remains yours, but you know the consequences.

Next to its 3-ton neighbours

The series has three 3-ton coils. This one is the narrowest at 17-1/2 in. The EVD5X36S21B and EVD5X37S21B are 21 in wide. All share R-454B refrigerant and the TXV expansion valve.

If your furnace is 17-1/2 in wide, this model is the natural choice. If it is 21 in, one of the other two is more appropriate. Below 3 tons, the series offers 2.5-ton models in the same 17-1/2 in width: the EVD5X30S17B and EVD5X31S17B.

Specifications

  • Model: EVD5X36S17B (Comfortmaker, EVD5X series);
  • Type: cased evaporator coil;
  • Nominal capacity: 3 tons, or 36,000 BTU/h;
  • Width: 17-1/2 in;
  • R-454B refrigerant, TXV expansion valve;
  • Vertical installation, upflow or downflow;
  • 3/8 in liquid connection, 3/4 in suction connection;
  • Sloped PBT condensate pan, 3 sealed plugs;
  • Factory-installed A2L leak sensor, without a dissipation board: furnace with built-in dissipation or the ACAENCDIS01A kit;
  • Limited warranty of 10 years on parts with registration within 90 days of installation, 5 years without registration.

The condensate of a large house

The bigger the system, the more water it removes from the air on muggy days. The sloped pan of the EVD5X36S17B, with its 3 sealed plugs, lets the outlet be directed to the most convenient drain. We check that the flow is free and the slope is sufficient, because an overflowing drain causes water damage that is noticed too late.

Heat pump and furnace: sharing the seasons

With a heat pump, this coil makes it possible to heat through the existing ducts. The furnace keeps its blower, its filters and its backup role. In mild weather, the heat pump supplies two to three times more heat than the electricity it consumes; it loses efficiency when it is very cold, and that is when the furnace takes over, below the threshold that we program with you.

In a large house, this sharing of tasks can make a noticeable difference on the electricity bill, but we do not promise a figure: it all depends on insulation, habits and the rate.

Ratings and certification

A coil has no efficiency rating of its own; the SEER2, EER2 and HSPF2 values attach to a matched system identified by an AHRI number. We confirm it before ordering. Comfortmaker also states that serial numbers ending in B (EVD5X..S..B) are not yet listed in ENERGY STAR; only those ending in A (EVD5X..M..A) are certified there with the Q5H9V and N5H9V heat pumps.

The job

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, insulated transition if needed, sealed duct joints;
  • outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment, explanation of how it works.

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our work is done under RBQ licence 5645-9605-01. Comfortmaker belongs to International Comfort Products (ICP), a subsidiary of Carrier.

To check before you buy

  • R-454B is shared by the coil and the outdoor unit, installed together.
  • The ratings apply to the certified match.
  • The furnace has the width, the blower and the ducts to handle a 3-ton system.

A two-storey house: the question of distribution

In a house with several floors, cool air sinks and warm air rises. In summer, the upper floor is often hotter than the ground floor; in winter, it is the reverse. A well-adjusted system, with airflow balanced between the vents, reduces this gap. We therefore look at how the ducts serve each floor before proposing anything.

Sometimes a simple adjustment of the registers is enough to rebalance. Sometimes a modification to a section is needed. We tell you plainly.

Why we do not promise a savings figure

A heat pump paired with this coil can reduce the heating consumption of a home heated with electricity, because it moves heat instead of producing it. But the exact amount depends on insulation, air tightness, the temperature you maintain and the electricity rate. A single figure would be a disservice.

What we can do is explain the mechanism and show you on site where the main possible gains lie.

After installation

Remember to register the unit within 90 days after installation: that is what takes the parts warranty from 5 to 10 years. Keep the invoice and the model number, EVD5X36S17B, close at hand.

One last piece of advice before deciding

Ask yourself whether your load calculation has really been done. Many systems are chosen based on the size of the old unit, which may itself have been poorly chosen. A calculation done on site, with your windows, your insulation and your ducts, is worth more than any rule of thumb.

Incentives

Eligibility for Hydro-Québec programs concerns the complete system. We check the match against the official list at the quote, according to the installation date, and tell you what applies.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVD5X36S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X36S17B
TypeCased evaporator coil
LineEVD5X
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 in
Model numberEVD5X36S17B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom