COMFORTMAKER EVD5X37S21B Evaporator V-Coil | 3 Tons
The Comfortmaker EVD5X37S21B 3-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVD5X37S21B
514 316-2973 · sales@airgreen.ca
Quick facts
EVD5X37S21B: warranty, maintenance and lifespan of a 3-ton, 21 in Comfortmaker coil
A coil is often chosen for its numbers, and people forget to ask what will happen in ten years. The Comfortmaker EVD5X37S21B is a cased V-type evaporator coil, rated at 3 tons nominal (36,000 BTU/h), 21 in wide, on R-454B refrigerant. This page looks at this model from the long-term angle: warranty, maintenance, drain and follow-up.
AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
The warranty, and the step that takes it from 5 to 10 years
The manufacturer offers a limited 10-year parts warranty, provided the product is registered within 90 days after installation. Without registration, the warranty is 5 years. The difference is considerable, and yet the step takes only a few minutes.
At AirGreen, we remind you of this step at the end of the job and help you do it if you wish. Then keep the registration confirmation with your invoice: it will be needed if a part has to be replaced.
What the warranty does not cover
This is a parts warranty. It says nothing about labour or about damage caused by poor maintenance. We prefer to tell you plainly: the best way to make the most of your warranty is to have the system installed correctly, then maintain it.
The condensate drain, weak point of neglected systems
The pan of the EVD5X37S21B is sloped and made of PBT. It offers 3 sealed plugs to direct the outlet according to your furnace. If the drain clogs, the water overflows and damages what is underneath. We recommend checking the flow at the start of each cooling season, and having the drain checked during a maintenance visit.
The maintenance you can do yourself
The furnace filter is the simplest part to maintain and the most neglected. A dirty filter reduces airflow, strains the blower and hurts the coil’s heat exchange. Check it regularly, and replace it as needed. Also keep the outdoor unit clear of leaves, snow and obstacles.
The A2L sensor: to know before you buy
The coil is delivered with a factory-installed A2L leak sensor, but without a dissipation board. A furnace with built-in dissipation, or the ACAENCDIS01A kit, is therefore required. We check this during the visit, so that the quote holds no surprises.
Where this model sits in the series
The EVD5X37S21B shares its 3-ton capacity and its 21 in width with the EVD5X36S21B, and the published characteristics are the same on our listings. The narrower EVD5X36S17B is 17-1/2 in wide. The other models in the series, from 1.5 to 2.5 tons, are smaller; none reaches this 21 in.
If two part numbers are possible, the certified match, then availability, decide.
Specifications
- Manufacturer: Comfortmaker, EVD5X series;
- Cased evaporator coil;
- Nominal capacity: 3 tons, or 36,000 BTU/h;
- Width: 21 in;
- R-454B, TXV expansion valve;
- Vertical positions: upflow or downflow;
- Connections: 3/8 in (liquid), 3/4 in (suction);
- Sloped PBT pan, 3 sealed plugs;
- A2L sensor without a dissipation board;
- Warranty of 10 years on parts with registration within 90 days, 5 years without.
Ratings and the match
A coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values attach to the matched system and its AHRI number, which we confirm before ordering. Comfortmaker states that serial numbers ending in B (EVD5X..S..B) are not yet in ENERGY STAR; only those ending in A (EVD5X..M..A) are, with the Q5H9V and N5H9V heat pumps.
Role in an add-on system
On a furnace, the coil cools the air in summer. With a heat pump, it also makes it possible to heat in winter through the same ducts. The furnace keeps its blower, its filters and its backup role, and takes over below the threshold that we program with you. In mild weather, the heat pump supplies two to three times more heat than the electricity it consumes.
Installation, step by step
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, insulated transition if needed, sealed ducts;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment, demonstration.
AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Comfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier.
Before choosing
- Same refrigerant, R-454B, for the coil and the outdoor unit.
- Ratings valid for the certified match.
- Furnace width, blower and dissipation to be confirmed at your home.
When to have the system inspected
An annual maintenance visit is not mandatory, but it is advisable. The technician checks the drain, verifies the connections, examines the condition of the coil and the filter, and makes sure the airflow is the one from the initial setup. If a problem is spotted early, the fix is generally simpler and less costly than a late repair.
A system that works well is rarely heard and even less often seen; maintenance aims to keep it that way for as long as possible.
Why keep the invoice and the model sheet
The EVD5X37S21B number, the installation date, the warranty registration confirmation and the AHRI number of the match are the four pieces of information you will need to provide if you ever request a warranty repair, a replacement part or a check of eligibility for a program. Keep them together.
A large house, a large coil: the overall logic
A 3-ton, 21 in coil pairs with a furnace and ducts of suitable size. We assess the whole before proposing the system, and we explain what we observed. If the ducts or the blower limit performance, we tell you, along with the possible options.
It is a way of working that may seem longer at the start, but it avoids many disappointments after installation.
The area we serve
We work on the island of Montreal, in Laval, in Longueuil and in the municipalities of the North Shore and the South Shore. The on-site estimate is free, and we confirm the address when you book.
Incentives
Hydro-Québec programs apply to the complete system. We consult the official list at the quote, according to the installation date, and explain what is eligible.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EVD5X37S21B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.