COMFORTMAKER EVD5X24S14B Evaporator V-Coil | 2 Tons
The Comfortmaker EVD5X24S14B 2-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVD5X24S14B
514 316-2973 · sales@airgreen.ca
Quick facts
Turning an electric furnace into a central heat pump with the 2-ton EVD5X24S14B
Many bungalows in the region still heat with an electric furnace: a blower, heating elements, and ducts that only get used in winter. The Comfortmaker EVD5X24S14B coil lets that installation work all year long. With a nominal capacity of 2 tons (24,000 BTU/h) and a width of 14-3/16 in, it fits on a compact furnace.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, always with the outdoor unit that goes with it.
The typical scenario: bungalow, electric furnace, ducts in good shape
If your ducts are in good condition, you already have the most expensive part of a central system. What is missing is a heat exchanger in the path of the air and a unit outside. The EVD5X24S14B plays the first role; a Comfortmaker outdoor unit of the same capacity plays the second.
The result: in summer, cool air blown into every room. In winter, with a heat pump, heat delivered through the same vents, and a furnace that only steps in on the coldest days. You avoid drilling through walls for wall-mounted units in every bedroom.
Why 2 tons?
Capacity is chosen according to the house, not according to preference. A well-insulated, single-storey home of average size is often comfortable with this size; a large two-storey house with a lot of glazing will need more. We do a load calculation before proposing anything, and we explain the numbers to you.
Equipment that is too big runs short cycles, leaves the air humid and wears out its components faster. Equipment that is well chosen runs longer and more gently, and the temperature stays steady from room to room.
How to choose it among its neighbours in the series
Four 2-ton coils are in the series: the EVD5X24S14B (14-3/16 in), the EVD5X24S17B (17-1/2 in), the EVD5X25S14B (14-3/16 in) and the EVD5X25S17B (17-1/2 in). On our listings, they share the same R-454B refrigerant, the same TXV expansion valve and the same capacity. What sets the EVD5X24S14B apart from its cousins is mainly the width: this one is narrower than the two 17-1/2 in models.
The EVD5X25S14B shows identical characteristics on the points we publish. If one of the two is hard to get, the other may do; we always confirm the exact match before ordering.
What we do on installation day
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, with an insulated transition built on site if the widths differ, and sealed duct joints;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment, explanation at your home.
EVD5X24S14B technical data
- cased evaporator coil, EVD5X series, manufacturer Comfortmaker;
- 2 tons nominal (24,000 BTU/h);
- R-454B refrigerant, TXV expansion valve;
- vertical positions, upflow or downflow;
- width of 14-3/16 in;
- liquid 3/8 in, suction 5/8 in;
- sloped PBT condensate pan, 3 sealed plugs;
- factory-installed A2L leak sensor, without a dissipation board: a furnace with built-in dissipation or the ACAENCDIS01A kit must be provided;
- limited warranty of 10 years on parts, with registration within 90 days of installation (5 years without registration).
The coil and the furnace: a division of tasks
In this setup, the furnace keeps what it does well: moving the air, filtering it and, if necessary, heating it. The coil adds cooling and, in winter, serves as the exchange point for the heat pump. It is a sharing of roles, not a replacement.
The outdoor temperature at which the furnace takes over is programmed with you. It depends on your home, your comfort and your electricity rate.
Efficiency: where to read the right ratings
A coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values attach to a complete system identified by an AHRI number. That is the number to ask for, and it is the one we check before the order.
Comfortmaker states that serial numbers ending in B (EVD5X..S..B) are not yet listed in ENERGY STAR; only the numbers ending in A (EVD5X..M..A) are, with the Q5H9V and N5H9V heat pumps. Approved matches can be looked up in the AHRI directory.
Frequently asked questions
Does this coil heat? Yes, when it is paired with a heat pump. With a simple central air conditioner, it only cools.
Can I keep my old air conditioner? Generally, no. The coil runs on R-454B and must connect to the outdoor unit designed for that refrigerant.
My furnace is not the same width. We measure it, then build an insulated transition if necessary.
Our company
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. Comfortmaker belongs to International Comfort Products (ICP), a subsidiary of Carrier.
Points to confirm before ordering
- R-454B refrigerant shared by the coil and the outdoor unit.
- Published ratings valid for the certified match only.
- A furnace with a suitable width and blower, checked during the visit.
Financial assistance
Hydro-Québec programs apply to the complete system, never to the coil alone. We validate the match against the official list at the time of the quote, taking the installation date into account.
Summer humidity: the coil’s real job
People often think an air conditioner is there to lower the temperature. It is there just as much to remove humidity. In Montreal, the muggy weeks of July make a house uncomfortable even at a reasonable temperature. A properly sized coil, with air passing through it unhurried, condenses the water out of the air and sends it down the drain.
That is one more reason not to oversize: a system that is too big reaches the requested temperature before it has done its work on humidity.
What changes in the house after installation
The most visible change is the relative quiet of the heating: no more electric elements switching on at every drop of the thermostat. The heat pump supplies heat more continuously, and the furnace only starts for the coldest days. The least visible is the electricity bill, which may go down because each kilowatt-hour produces more heat than it does with simple elements.
We do not promise a specific figure: it depends on your house, its insulation and your habits. We prefer to show you how it is calculated during the visit.
An installation that respects your home
The existing ducts stay in place, and the coil is installed in the furnace plenum. There is no major plaster work and no opened walls, unless a piping route requires it. We protect the floors, we clean up the job site and we explain what we are doing at each step.
The electrical work is done under our licence, so that the connection of the outdoor unit and the thermostat is compliant.
When to choose a wider or larger model instead
If, during the visit, we find a 17-1/2 in furnace, we will steer you toward the EVD5X24S17B or the EVD5X25S17B. If the calculated load exceeds what 2 tons can provide, the series then offers 2.5-ton sizes (EVD5X30S14B, EVD5X30S17B, EVD5X31S17B) and 3-ton sizes. What matters is that the decision rests on a measurement, not on a hunch.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EVD5X24S14B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-3/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.