COMFORTMAKER EVD5X25S17B Evaporator V-Coil | 2 Tons

In stock

The Comfortmaker EVD5X25S17B 2-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVD5X25S17B

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD5X25S17B
ManufacturerComfortmaker
Size2 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV

EVD5X25S17B: comparing quotes for a 2-ton Comfortmaker system with a 17-1/2 in cabinet

You have received two or three quotes for a central system, and they do not look alike. One mentions a "2-ton coil", another cites a model number, the third talks about the brand only. How do you make sense of it? This page takes the Comfortmaker EVD5X25S17B as an example to show you what a good quote should spell out.

This 2-ton coil (24,000 BTU/h) is 17-1/2 in wide. It is cased and runs on R-454B. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What a serious quote must contain

The exact model of the coil, first. The exact model of the outdoor unit, next. The refrigerant. And above all the AHRI number of the match, because that is what ties the efficiency ratings to a real system. A coil taken on its own has none.

If someone talks to you about SEER2, EER2 or HSPF2 without an AHRI number, ask where those values come from. At AirGreen, we confirm this number before ordering, so that you receive what was promised.

The EVD5X25S17B in brief

It is a V-coil, installed vertically with upflow or downflow airflow, for a furnace or a blower cabinet. It cools in summer; with a heat pump, it also takes part in heating in winter. The expansion valve is a TXV.

Its 2-ton twin at 17-1/2 in is the EVD5X24S17B, whose published characteristics are the same. The two narrow versions, the EVD5X24S14B and EVD5X25S14B, are 14-3/16 in wide.

The same serial-number format does not mean the same status

Comfortmaker states that serial numbers ending in B, like the EVD5X25S17B (EVD5X..S..B), are not yet in ENERGY STAR. Only the numbers ending in A (EVD5X..M..A) are certified there, with the Q5H9V and N5H9V heat pumps. That does not mean one model is inferior to the other; it means the ENERGY STAR list does not cover every match.

The AHRI directory remains the reference for approved matches. We consult it before every order.

Measure rather than guess

A 17-1/2 in coil suits a furnace of that width. On a narrower furnace, a transition will be needed; on a wider one, too. We measure the plenum during the estimate, and if there is a gap, we build an insulated transition on site.

Detailed specifications

  • Model: EVD5X25S17B, made by Comfortmaker;
  • Family: cased evaporator coils, EVD5X series;
  • Capacity: 2 tons (24,000 BTU/h);
  • Width: 17-1/2 in;
  • R-454B refrigerant, TXV expansion valve;
  • Liquid connection: 3/8 in; suction connection: 5/8 in;
  • Sloped PBT condensate pan with 3 sealed plugs;
  • A2L leak sensor supplied without a dissipation board: the furnace must include dissipation, or the ACAENCDIS01A kit is needed;
  • Limited warranty of 10 years on parts with registration within 90 days of installation (5 years without registration).

How the furnace and the heat pump share the work

In an add-on system, the furnace keeps its blower, its filters and its backup role. The heat pump handles most of the heating in mild weather, because it supplies two to three times more heat than the electricity consumed. When the cold becomes too sharp, the furnace takes over, at the threshold we program with you.

This sharing of tasks explains why two houses that look identical can have different settings: it all depends on your comfort, your insulation and what you want to pay for electricity.

A job with no gray areas

  • measuring the furnace, checking the blower and the panel;
  • installation in the plenum, sealed ducts, transition if needed;
  • outdoor unit, brazed piping, nitrogen test, evacuation;
  • connecting the drain and the thermostat;
  • commissioning and explanation.

AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years and holding RBQ licence 5645-9605-01. Comfortmaker is part of International Comfort Products (ICP), a subsidiary of Carrier.

To check before signing

  • Same refrigerant (R-454B) for the coil and the outdoor unit.
  • Efficiency ratings tied to a specific AHRI number.
  • Furnace of the right width, suitable blower, A2L sensor taken into account.

An estimate visit, concretely

When we come to your home, we start by looking at the furnace: its make, its width, the condition of the blower, the way it is connected to the ducts. Then we move on to the electrical panel, to see whether the electrical service can accommodate an additional outdoor unit. Finally, we look for the best location for that unit: accessible, clear, not too close to bedroom windows.

We also ask you a few questions about how you live: which rooms are hot in summer, which are cold in winter, who is home during the day. Those answers guide the setup of the thermostat and the furnace far more than a catalogue sheet does.

The coil, the furnace and the plenum: what fits into what

The plenum is the sheet-metal box that connects the furnace to the ducts. The coil cabinet sits there. Its opening must be compatible with the width of the cabinet, here 17-1/2 in. When it is not, we build an insulated transition on site: sheet-metal work that ensures airtightness and limits losses of heat or coolness.

A poorly sealed joint lets conditioned air leak into the basement or the attic. That is why we put as much care into the airtightness of the ducts as into the refrigerant connection.

What a good adjustment changes

Once the system is in service, we adjust the airflow. Airflow that is too low frosts or clogs the coil; airflow that is too high lets the air pass too quickly to be properly cooled or dehumidified. This step is not visible, but it determines day-to-day comfort.

We then give you the simplest maintenance instructions: where the filter is, how often to check it, and what to do if the drain seems slow.

The other 2-ton models, side by side

  • EVD5X24S14B: 14-3/16 in;
  • EVD5X24S17B: 17-1/2 in;
  • EVD5X25S14B: 14-3/16 in;
  • EVD5X25S17B (this one): 17-1/2 in.

For all four, the refrigerant is R-454B and the expansion valve is a TXV. A 2.5-ton or 3-ton size becomes relevant if the load calculation calls for it, not before.

A word on project duration

We do not give you a standard duration, because it depends on access to the furnace, the distance to the outdoor unit and the condition of the ducts. During the visit, we tell you what we expect and we set a date together that suits you, taking equipment availability into account.

Incentives

Hydro-Québec programs apply to the matched system, never to the coil alone. We validate the match against the official list at the time of the quote and according to the installation date, then tell you what applies to your project.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVD5X25S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Comfortmaker outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVD5X25S17B
TypeCased evaporator coil
LineEVD5X
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection5/8 in
Dimensions W × H × D17-1/2 in
Model numberEVD5X25S17B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.