COMFORTMAKER EVD5X31S17B Evaporator V-Coil | 2.5 Tons
The Comfortmaker EVD5X31S17B 2.5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVD5X31S17B
514 316-2973 · sales@airgreen.ca
Quick facts
EVD5X31S17B: understanding R-454B refrigerant and the A2L sensor on a 2.5-ton Comfortmaker coil
New air conditioning and heat pump systems are changing refrigerant, and it shows right down to a coil’s spec sheet. The Comfortmaker EVD5X31S17B is a good example: a cased V-type evaporator coil, 2.5 tons nominal (30,000 BTU/h), 17-1/2 in wide, on R-454B, with a factory-installed A2L leak sensor. This page explains what those words mean for your home.
AirGreen installs this model in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
What does "A2L" mean?
The abbreviation designates a category of refrigerants that R-454B belongs to. For a homeowner, the practical consequence is simple: the coil includes a sensor that monitors for refrigerant and triggers a response if a leak is detected. This sensor is factory-installed on the EVD5X31S17B.
What the sensor does not do is handle the dissipation itself. It is supplied without a dissipation board. The furnace must therefore provide it, if it has it built in, or the ACAENCDIS01A kit must be added. We check this during the visit, and the quote takes it into account.
Why matching the same refrigerant is non-negotiable
R-454B does not mix with the older fluids. The coil and the outdoor unit must therefore run on the same one, and they are installed together. If your existing air conditioner uses a different refrigerant, it cannot serve as a partner to this coil; the outdoor unit specified by the manufacturer will have to be installed.
This is not an arbitrary rule. Operating pressures, lubricants and circuit components are chosen for a given fluid.
The EVD5X31S17B among the 2.5-ton models
Three models exist for this capacity in the series: the EVD5X30S14B (14-3/16 in), the EVD5X30S17B (17-1/2 in) and this one (17-1/2 in). The two 17-1/2 in models show the same data on our listing. If your furnace is narrow, the EVD5X30S14B is the one to look at.
Above, the 3-ton EVD5X36S17B shares the same width. Below, the 17-1/2 in 2-ton models are the EVD5X24S17B and EVD5X25S17B. The choice of capacity rests on the load calculation, and the choice of width on the plenum measurement.
What does not change: a coil doing its job as a heat exchanger
Despite the new vocabulary, the principle remains that of a heat exchanger. The refrigerant evaporates in the tubes and captures the heat of the air passing through them. The water in the air condenses and runs into the pan, then into the drain. With a heat pump, the cycle reverses in winter and the heat captured outside is delivered to the air of the house.
The expansion valve on this model is a TXV, which adjusts the refrigerant flow according to the load.
EVD5X31S17B specifications
- Manufacturer: Comfortmaker, EVD5X series;
- Cased evaporator coil;
- Nominal size: 2.5 tons, or 30,000 BTU/h;
- Width: 17-1/2 in;
- Refrigerant: R-454B;
- Expansion valve: TXV;
- Positions: vertical, upflow or downflow;
- Connections: 3/8 in for the liquid, 3/4 in for the suction;
- Drain: sloped PBT pan, 3 sealed plugs;
- Leak detection: factory-installed A2L sensor, without a dissipation board;
- Warranty: limited to 10 years on parts with registration within 90 days of installation, or 5 years without registration.
The efficiency ratings are not on the coil’s spec sheet
Look for them on the system side. The SEER2, EER2 and HSPF2 values attach to a match and its AHRI number. We confirm this number in the AHRI directory before ordering.
Comfortmaker states that serial numbers ending in B (EVD5X..S..B) are not yet in ENERGY STAR. Only the numbers ending in A (EVD5X..M..A) are certified there, with the Q5H9V and N5H9V heat pumps.
And the furnace in all this?
It keeps playing its role. In an add-on setup, its blower, filters and heating elements remain in service. The coil is installed in the plenum, and the furnace takes over when the outdoor temperature drops below the threshold that we program with you.
In mild weather, a heat pump supplies two to three times more heat than the electricity it consumes, which explains the appeal of this setup for homes heated with electricity.
How our work unfolds
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil, insulated transition if needed, sealed ducts;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;
- condensate drain and thermostat connected;
- commissioning, airflow adjusted, demonstration.
Questions we are often asked
Can the coil heat? Yes, with a heat pump. With a central air conditioner, it only cools.
Can I keep my current air conditioner? Generally no: it must be the outdoor unit designed for this refrigerant.
Is the furnace still useful? Yes, as backup heat.
My furnace is not the same width. We build an insulated transition on site.
The company behind the installation
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. Comfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier.
Before deciding
- R-454B refrigerant shared by the coil and the outdoor unit.
- Ratings tied to the certified match.
- A furnace with a suitable width and blower, with built-in dissipation or the kit.
What this changes for future maintenance
An R-454B system is maintained like any other: clean filter, clear outdoor unit, free drain. The difference lies mainly in handling the refrigerant, which must be done by a qualified technician. Do not attempt to work on the piping or the sensor yourself.
If an alarm or an indicator light signals a problem, shut the system off and call us. We would rather get a call for nothing than have a leak go ignored.
How we present the options
When we hand over a quote, we list the model of the coil, that of the outdoor unit, the refrigerant and the AHRI number. If a dissipation kit is required, it appears separately, with the reason for it. You can thus compare our offer with others, line by line, without guessing what is included.
We prefer a long, clear quote to a short one that leaves gray areas. It is also the best way to avoid misunderstandings on installation day.
A medium to large house
The 2.5-ton size is often the one for medium-sized two-storey houses, well-insulated cottages and bungalows a little larger than average. Here again, it is the load calculation that decides, not floor area or the reputation of a size. We spend the time needed at your home to do it properly.
Incentives
Hydro-Québec programs apply to the complete system. We consult the official list at the quote, according to the installation date, and tell you what is eligible.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EVD5X31S17B sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.