GOODMAN CAPEA2418B3 Evaporator A-Coil | 2 Tons

In stock

The Goodman CAPEA2418B3 2-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV6SA1810A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPEA2418B3

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 217589358
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPEA2418B3
ManufacturerGoodman
Size2 tons
Width17-1/2 in
RefrigerantR-32
MeteringEEV
Outdoor unitGZV6SA1810A

CAPEA2418B3: the narrow 2-ton evaporator coil for the plex and the townhouse

In a plex unit or a row house, the furnace is rarely tucked into a big mechanical room. It sits in a closet between the washing machine and the water heater, and every inch counts. That is exactly where the Goodman CAPEA2418B3 makes sense: an evaporator A-coil that comes with its cabinet, only 17-1/2 in wide, with a nominal size of 2 tons (24,000 BTU/h) and running on R-32 refrigerant.

We install it for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore. This page explains what this coil does, which homes it suits, how it compares with the other models in the CAPEA line, and what we check before ordering a single part.

What the CAPEA2418B3 does in your system

The coil is the part that exchanges heat with the air in your home. It slides into the plenum, right above the furnace or the blower cabinet. Warm air from your rooms passes through its fins, the liquid refrigerant evaporates inside and carries the heat outdoors. The water that condenses on the metal drips into the pan and leaves through the drain.

On its own, it does nothing: it waits for refrigerant from an outdoor unit. Paired with a central air conditioner, it cools. Paired with a heat pump, the cycle can reverse and the same piece of metal becomes the source of winter heat, through the ductwork you already have.

Why 17-1/2 in makes all the difference in a small space

Width is the first measurement we take. A cabinet has to match the furnace it sits on. When the furnace is narrow, a wider cabinet forces a makeshift transition, and every transition adds work and more joints to seal.

The CAPEA2418B3 is the narrowest in the series, tied with the other 17-1/2 in models. It measures 17-1/2 × 18 × 21 in (width, height, depth): a modest height, useful when the basement ceiling is low or when the return plenum is tight.

Which homes is a 2-ton size right for?

Think of a brick duplex in the Plateau, a triplex whose top floor has its own furnace, a small bungalow on the South Shore, a compact cottage in Laval. Modest floor areas, tight windows, a well-insulated floor: that is the territory for this size.

The trap is oversizing. A system that is too big reaches the set temperature in a few minutes, shuts off, then starts again. The air is cooled but not dehumidified, and you end up with a house that is cool and clammy. A room-by-room load calculation done at your home avoids this mistake. If it shows you need more than 2 tons, we will tell you plainly.

What happens in an "add-on" system

The term describes a heat pump added to an existing furnace. The furnace keeps its blower, its filters and its backup heating logic. The coil is inserted into the airflow path. In mild weather, the heat pump supplies almost all of the heat. When the cold turns severe, the furnace takes over, starting from a temperature threshold that we set together.

The metering device on this model is an EEV, an electronic expansion valve: it meters the refrigerant sent into the tubes according to the needs of the moment, rather than according to a fixed setting.

The published match: the GZV6SA1810A outdoor unit

For this coil, the manufacturer publishes a single match: the Goodman GZV6SA1810A outdoor heat pump. The complete system carries AHRI number 217589358. Its published figures are as follows: 17,000 BTU/h in cooling, 16,800 BTU/h in heating at 47 °F, SEER2 19.0, HSPF2 8.8.

Keep this AHRI number handy. The coil has no efficiency rating on its own: the ratings describe the trio made up of the coil, the outdoor unit and the blower. Two quotes can therefore only be compared if their AHRI numbers are known.

CAPEA2418B3 or its neighbours: how to choose

  • Versus the CAPEA2418C3: same 2-ton size, same GZV6SA1810A outdoor unit, but the C3 is 21 in wide. Choose the B3 if the furnace is narrow, the C3 if it is wider.
  • Versus the CAPEA3022B3: same 17-1/2 in width, but 2.5 tons. The extra capacity only helps if the home's load justifies it.
  • Versus the 3, 4 and 5-ton models: they are meant for much larger homes, and several are offered in 21 in or 24-1/2 in widths.

The rule is simple: choose the width from the furnace, and the capacity from the house. The two decisions are independent, and we make them one after the other.

What is published for this model

  • Piping connections: 5/16 or 3/8 in for the liquid line, 5/8 or 3/4 in for the suction line.
  • Drainage: 3/4 in FNPT condensate drain, with one primary and one secondary outlet.
  • Positions: upflow or downflow; the downflow position requires the DFKE-02 kit for the 4830 and 6030 models.
  • Safety: an R-32 refrigerant sensor, designed to last as long as the coil, detects any possible leak.
  • Manufacturer's warranty: 10 years on parts, with online registration within 60 days of installation, which is not required in Quebec.

R-32 and why everything is installed together

The coil is designed for R-32. It does not pair with just any old air conditioner left in the yard. In general, we install the coil and the outdoor unit on the same day, with the same refrigerant charge, which removes any compatibility doubts.

If your current air conditioner still works well, tell us: we will honestly assess what can be reused and what cannot. But an R-32 coil needs an outdoor unit that uses the same refrigerant, and that usually rules out reuse.

The visit, the installation and the commissioning

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, and our work is covered by our RBQ licence 5645-9605-01. Here is how a project like this unfolds:

  • We measure the furnace, look at the blower and take a quick look at the electrical panel.
  • The coil is installed in the plenum; the joints between the cabinet and the ducts are sealed.
  • The outdoor unit goes on a pad or a bracket, and the piping is brazed. We then pressure-test with nitrogen and pull a vacuum.
  • The condensate drain and the thermostat are connected.
  • At commissioning, we set the airflow and walk you through how it works, thermostat in hand.

Frequently asked questions about the CAPEA2418B3

Can it heat? Yes, as long as it is paired with a heat pump. With a central air conditioner, it only cools.

My furnace is a different width, what then? We measure it and, if needed, build an insulated transition on site.

Is the furnace still used? Yes. It keeps its blower and takes over when the outdoor temperature drops below the programmed threshold.

Before ordering: three points to confirm

  • The R-32 refrigerant means the coil must be paired with an outdoor unit that uses the same refrigerant, installed at the same time.
  • The published ratings apply to the certified match, not to a makeshift assembly.
  • The furnace blower must be able to deliver the required airflow; we check this on site.

LogisVert incentive

The matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list at the time of the quote, then put the application together with you.

Request your estimate

Book a free visit: we measure the furnace, look at the electrical entrance and give you a written quote for the complete Goodman system. To spread out the cost, financing is available.

01 · What it is for

The heat pump coil for your furnace

The CAPEA2418B3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV6SA1810A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Goodman GZV6SA1810A outdoor unit
Certified systemMatched with the GZV6SA1810A, the system carries AHRI 217589358.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPEA2418B3
TypeCased evaporator coil
LineCAPEA
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-32
Metering deviceEEV
Liquid connection5/16 or 3/8 in
Suction connection5/8 or 3/4 in
Dimensions W × H × D17-1/2 × 18 × 21 in
Matched outdoor unitGZV6SA1810A
System AHRI number217589358
System SEER2 / HSPF219.0 / 8.8
Model numberCAPEA2418B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Goodman coil, installed by AirGreen