GOODMAN CAPEA3626C3 Evaporator A-Coil | 3 Tons
The Goodman CAPEA3626C3 3-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV7SA2410A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPEA3626C3
514 316-2973 · sales@airgreen.ca
Quick facts
Reading a quote for the CAPEA3626C3: 3 tons, 21 in, AHRI number 217589286
You have received two or three quotes for a central heat pump, and the numbers look alike without really lining up. This page helps you decode what an offer that includes the Goodman CAPEA3626C3 should contain. It is a cased evaporator A-coil of 3 tons (36,000 BTU/h), running on R-32 refrigerant, in a cabinet 21 in wide.
We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here, point by point, is what to look for in the paperwork you are handed.
First line: the exact model
A serious quote names the coil by its full number. Here: CAPEA3626C3. The letters and digits have a practical meaning. In the 3-ton series, the last letter before the 3 distinguishes the cabinet width: B for 17-1/2 in, C for 21 in, D for 24-1/2 in. If the document says only "3-ton coil," ask which one.
Second line: the outdoor unit
The manufacturer publishes, for this coil, a match with the Goodman GZV7SA2410A heat pump. Look for it in the quote. If another unit appears there, the system may not be the one whose ratings are published, and you should ask why.
Third line: the AHRI number
For this match, the number is 217589286. The published ratings for the system: 23,200 BTU/h in cooling, 23,200 BTU/h in heating at 47 °F, SEER2 19.0, HSPF2 8.6. The coil has no rating on its own. This number ties the components together and lets you check the figures against an official list.
Fourth line: the size and the width
The 3-ton size suits a medium to large home. The 21 in width, for its part, must match that of the furnace. The published dimensions are 21 × 26 × 21 in (width, height, depth). When the furnace is not that width, the quote must mention the insulated transition that we build on site.
Fifth line: the connections and the drain
The coil accepts connections of 5/16 or 3/8 in for the liquid line and 3/4 or 7/8 in for the suction line. Its condensate pan has a 3/4 in FNPT drain, with one primary and one secondary outlet. Check that the quote provides for where the water will go: floor drain, condensate pump or another solution.
Sixth line: the piping and the commissioning
A good offer mentions brazing of the piping, the nitrogen leak test and the vacuum. These steps, more than the price of the coil, determine how long a system lasts. If they appear nowhere, ask for them.
Seventh line: the warranty
The manufacturer publishes a limited 10-year warranty on parts. Online registration within 60 days of installation is mentioned in its sheet, and is not required in Quebec. Ask for clarity on who covers the labour and for how long: that is up to the installer.
What the quote should say about your furnace
A good document describes the equipment in place: brand, approximate age, width, direction of airflow. It shows that the installer came to measure, instead of copying a catalogue sheet. If your furnace is old, the quote should also mention the condition of the blower and the filter, since the airflow through the coil depends on them.
What the quote should say about your home
To validate that a 3-ton size is appropriate, a serious offer relies on a load calculation: windows, insulation, orientation, number of rooms served. Such a calculation takes time, but it costs less than a poorly chosen unit. If you are offered a size without anything having been measured, compare with caution.
At AirGreen, this calculation is part of the visit. If the result points to 2.5 or 4 tons, we change models and explain why.
The classic pitfalls of a comparison
- Comparing two systems whose AHRI numbers differ without knowing it.
- Mistaking a coil's efficiency rating for the system's.
- Forgetting the cost of the transition when the width does not match.
- Neglecting the condensate drain and its route.
Eighth line: the incentive
The amount of an incentive depends on the complete system, never on the coil alone. The matched system appears on Hydro-Québec's list of eligible heat pumps; the exact amount depends on the installation date and your situation. An honest quote does not promise a figure before the official list has been checked.
And the C3 against its neighbours?
- CAPEA3626B3: same capacity and outdoor unit, but 17-1/2 in wide.
- CAPEA3626D3: same capacity and outdoor unit, but 24-1/2 in wide.
- CAPEA3022C3: same 21 in width, but 2.5 tons, with two possible matches.
- CAPEA4830C3: same width, 4 tons, with the GZV9SA241CA unit as the first reference.
To compare, you only need to ask two questions: what is the width of my furnace, and what load does my house impose?
A word on summer and winter
For air conditioning, the coil cools the air and removes its moisture; that is what makes July heat bearable in a home in Laval or on the South Shore. For heating, a matched heat pump moves heat from outdoors into the air of the house, and the furnace stays there as backup when the outdoor temperature drops below the threshold we program with you. The thermostat controls the whole thing: one device to set for both seasons.
R-32 refrigerant and its consequences
The coil uses R-32 and must be paired with an outdoor unit that uses the same refrigerant, installed along with it. An R-32 leak sensor, designed to last as long as the coil, is part of the design. The expansion device is an EEV type. In general, an existing air conditioner therefore cannot be kept.
How the installation goes
- Visit, measuring the furnace, checking the blower and the electrical panel.
- Coil installed in the plenum, joints sealed, transition built as needed.
- Outdoor unit on a pad or bracket, piping brazed, nitrogen test, vacuum.
- Drain and thermostat connected.
- Commissioning and a walkthrough for the household.
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01.
What to validate before signing
- The complete R-32 match, installed at the same time.
- The agreement between the displayed ratings and the AHRI number.
- The width of the furnace and the capacity of its blower.
Next: a quote you can compare
We offer a free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system, with all the numbers above. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPEA3626C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV7SA2410A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV7SA2410A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.