GOODMAN CAPEA6030D3 Evaporator A-Coil | 5 Tons
The Goodman CAPEA6030D3 5-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV7SA3610A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPEA6030D3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPEA6030D3: five common beliefs about a 5-ton, 24-1/2 in coil
A large coil attracts beliefs. "Bigger is safer." "The number on the box is the efficiency." "My old air conditioner will do fine with it." The Goodman CAPEA6030D3 is a cased evaporator A-coil of 5 tons (60,000 BTU/h), running on R-32 refrigerant, in a cabinet 24-1/2 in wide: the largest in the CAPEA line by both capacity and width.
Here is what we tell the homeowners in Montreal, Laval, Longueuil, on the North Shore and on the South Shore who ask us these questions.
Belief: bigger is safer
False, and in fact the opposite. A system that is too big reaches the set point quickly, shuts off, then starts again: the air is cooled without being dried, and the house becomes clammy. The right size is the one the load calculation confirms. For a very large, heavily glazed or very open home, 5 tons can be justified; for a home that is simply large, a smaller size is sometimes enough. We tell you so even if it changes the model.
Belief: the efficiency rating is written on the coil
Not that either. The coil has no efficiency rating of its own. SEER2 and HSPF2 belong to the matched system, identified by an AHRI number. For this coil, the manufacturer publishes three systems:
- GZV7SA3610A, AHRI 217589305: cooling 35,000 BTU/h, heating 35,000 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.5;
- GZV9SA361CA, AHRI 216699918: cooling 34,200 BTU/h, heating 32,600 BTU/h at 47 °F, SEER2 19.0, HSPF2 9.2;
- GZV9SA4810A, AHRI 217989208: cooling 46,000 BTU/h, heating 47,000 BTU/h at 47 °F, SEER2 18.0, HSPF2 9.0.
Note that these ratings differ from one system to the next while the coil stays the same: proof that the rating follows the outdoor unit and the whole assembly, not the part alone.
Belief: my old air conditioner will do fine with it
In general, no. The coil runs on R-32 and must be matched with an outdoor unit that uses the same refrigerant, installed along with it. It is designed with an R-32 leak sensor to last as long as the coil. Mixing generations of equipment invites uncertain operation that nobody can certify. We install the complete system.
Belief: a big furnace means a big cabinet, automatically
The width of the cabinet must match that of the furnace, not the capacity. The D3 measures 24-1/2 × 30 × 21 in (width, height, depth). Its 21 in twin, the CAPEA6030C3, offers the same capacity, the same three matches and the same height of 30 in. Only the width changes. We measure the furnace, and if needed we build an insulated transition on site.
Belief: the coil replaces the furnace
In an "add-on" system, the furnace keeps its blower, its filters and its backup role. The coil fits into the plenum and works with it. In winter, with a heat pump, the cycle reverses and the coil passes heat to the air; when the outdoor temperature drops below the threshold programmed with you, the furnace takes over. The existing ducts serve all year round.
And the question of noise and comfort?
Many people fear that a large system will be noisy. Noise depends mostly on the speed of the air in the ducts and on where the outdoor unit sits, not on the coil alone. We choose the location of the unit so that it does not face a bedroom window, and we set the airflow at commissioning. The result is judged by ear, room by room, before we leave.
On comfort, in summer the coil removes moisture from the air; in winter, heat arrives through the same vents as before. You do not have to learn a new way of living: the thermostat remains the only device to set for both seasons.
A South Shore home, a concrete example
Consider a large residence on the South Shore, whose original furnace was replaced a few years ago with a wider model. The owner wants to add air conditioning and, eventually, reduce dependence on electricity for heating. We measure the furnace, find a width of 24-1/2 in, calculate the load and, if it justifies it, propose the CAPEA6030D3 with one of the three published units. If the load is more moderate, we propose the CAPEA4830D3 instead, of the same width. In both cases, the cabinet fits the furnace without improvisation.
Where this model sits in the series
- CAPEA6030C3: same capacity, 21 in wide.
- CAPEA4830D3: same 24-1/2 in width, 4 tons, two published matches.
- CAPEA3626D3: same width, 3 tons, a single match.
The technical data, no detours
- EEV expansion device.
- Connections: 3/8 in (liquid), 7/8 or 1-1/8 in (suction).
- 3/4 in FNPT condensate drain, with primary and secondary outlets.
- Upflow or downflow positions; DFKE-02 kit for the 4830 and 6030 models in downflow.
- Limited 10-year warranty on parts; online registration within 60 days of installation, not required in Quebec.
The electrical entrance and the blower, two essential checks
A system of this size draws on the outdoor unit's power supply and on the blower's airflow. We check the panel, the circuit capacity and the blower before proposing a match. If the electrical entrance is too tight, we tell you at the visit.
What we do on installation day
- Measuring the furnace, checking the blower and the panel.
- Coil installed in the plenum, duct connections sealed.
- Outdoor unit on a pad or bracket, piping brazed, nitrogen test, vacuum.
- Drain and thermostat connected.
- Commissioning and explanation of how it works.
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01.
To check before buying
- R-32 outdoor unit, installed at the same time.
- Published ratings: valid for the certified match.
- Furnace of the right width, with a sufficient blower.
LogisVert incentive
The matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the time of the quote and prepare the application with you.
Request your estimate
Our estimate is free and done at your home: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPEA6030D3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV7SA3610A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV7SA3610A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.