GOODMAN CAPEA2418C3 Evaporator A-Coil | 2 Tons
The Goodman CAPEA2418C3 2-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV6SA1810A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPEA2418C3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CAPEA2418C3: 2 tons in a cabinet 21 in wide
Two furnaces of the same capacity can have very different bodies. The one in your basement may be wider than the average small model, and that is precisely what the CAPEA2418C3 exists for. It has the same core as its narrower cousin, 2 tons (24,000 BTU/h) on R-32 refrigerant, but its insulated cabinet spans 21 in in width.
This page is for you if you are replacing an old central air conditioner, thinking about turning your furnace into a heat pump system, or comparing quotes across Montreal, Laval, Longueuil, the North Shore and the South Shore. We will talk about width, capacity, matching and installation, without needless jargon.
Width first, the rest after
When we visit a home, the tape measure comes out before the calculator. A coil cabinet sits on top of the furnace and has to fit onto it. If it is too narrow, air can bypass the fins; if it is too wide, we have to build a transition fitting.
The CAPEA2418C3 measures 21 × 18 × 21 in (width, height, depth). Its height of 18 in is the same as its narrower neighbour: only the width changes. It is a logical model for a somewhat wider furnace, often an older one, that has already served as the base for air conditioning for years.
The right reflex: measure, then compare
Here is the method we suggest, whichever supplier you choose:
- Note the outside width of the furnace, including the outlet plenum.
- Note the direction of airflow: upflow or downflow.
- Photograph the nameplate, so that we know what is installed.
- Have a technician confirm the load of the home.
With these four items in hand, choosing between the models in the series becomes almost mechanical.
What the coil actually does
Picture a pleated sheet of metal, threaded with copper tubes, through which a very cold refrigerant circulates. The air from the house passes through this assembly; it loses its heat and a good share of its moisture. The condensation runs off through the 3/4 in FNPT drain, with one primary and one secondary outlet.
In summer, the captured heat goes to the outdoor unit. In winter, with a heat pump, the direction is reversed and the coil gives up heat to the air. It is simple mechanics, but it depends entirely on the quality of the match and on tightly sealed joints.
The certified system with the GZV6SA1810A unit
For this coil, the manufacturer publishes a match with the GZV6SA1810A outdoor heat pump, registered under AHRI number 217589358. The system figures: 17,000 BTU/h in cooling, 16,800 BTU/h in heating at 47 °F, SEER2 19.0, HSPF2 8.8.
Note that these ratings belong to the whole assembly. The coil alone carries none. The AHRI number is what lets you check, on the official list, what the trio of coil, outdoor unit and blower can really deliver.
C3, B3 or another: the selection guide
- CAPEA2418B3: same capacity and same outdoor unit, but only 17-1/2 in wide. Ideal for the narrow furnaces found in small mechanical closets.
- CAPEA3022C3: same 21 in width, but 2.5 tons. It suits homes one size larger.
- CAPEA3626C3 and the models after it: 3 tons and up; they are meant for heavier loads.
- The 24-1/2 in models: reserved for even wider furnaces, starting at 3 tons.
In other words, the 2-ton C3 is for when the furnace is wide and the house is modest. If it is the other way around, a narrow furnace and a large house, you will need to consider something else, and we will guide you.
What this spec sheet contains
- Type: evaporator coil with cabinet (cased), CAPEA line.
- Electronic expansion, EEV type.
- Piping: 5/16 or 3/8 in liquid line; 5/8 or 3/4 in suction line.
- Upflow or downflow installation, with the DFKE-02 kit for the 4830 and 6030 models in the downflow position.
- R-32 leak sensor designed for the service life of the coil.
- Limited 10-year warranty on parts, with online registration within 60 days of installation, a formality not required in Quebec.
R-32: a detail that matters
This refrigerant is the one used by the new generation of equipment. The coil and the outdoor unit therefore have to be on the same team. That is why the answer to "can I keep my old air conditioner?" is, in general, no. We prefer to say so clearly rather than let you find out about an incompatibility afterwards.
Installation day
The AirGreen team, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. The job always follows the same thread:
- measuring the furnace and checking the blower and the electrical panel;
- installing the coil in the plenum and sealing the duct joints, with a custom transition if the width requires it;
- setting up the outdoor unit, brazing the piping, nitrogen test, vacuum;
- connecting the drain and the thermostat;
- start-up, airflow adjustment and a walkthrough for the household.
Summer comfort: what you notice first
Homeowners who switch from window air conditioners to a central system talk first about the quiet in the bedrooms, then about the drier air. A single outdoor unit replaces several window units, the screens go back in their place and the light returns to the rooms.
A well-calculated 2-ton size runs longer per cycle, which gives the air time to dehumidify. It is this comfort, more than the temperature on the display, that makes the difference in July in a cottage in Laval or a bungalow on the North Shore.
What role the furnace keeps
Installing a coil on a furnace does not retire it. It keeps circulating the air with its blower, it keeps its filters and it stays ready for the deep cold. In a system paired with a heat pump, it is a duo: the heat pump works in milder temperatures, and the furnace steps in at lower ones, below a threshold that we choose with you at start-up.
This split also protects the furnace: it runs fewer hours per year and goes through fewer start-up cycles.
Coil maintenance over the years
A clean coil works better. The furnace filter is the first line of defence: a clogged filter strains the blower and lets dust through to the fins. We recommend checking it regularly, especially during the season when cooling and heating alternate, and reporting any unusual leakage at the condensate pan.
Quick answers
Does it heat in winter? Yes with a heat pump; otherwise, it only provides air conditioning.
My furnace has a different width? We build an insulated transition on site.
Is it eligible for incentives? Eligibility depends on the matched system; we check it according to the installation date.
To confirm before buying
- The match with an R-32 outdoor unit installed at the same time.
- The agreement between the displayed ratings and the certified match.
- The blower's ability to push the necessary airflow; we measure it at your home.
LogisVert incentive
This Goodman system is listed on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your file: we read it from the official list at the time of the quote and prepare the application with you.
Request your estimate
A no-charge visit is all it takes: we measure the furnace, check the electrical entrance and leave a written quote for the complete Goodman system. Financing lets you spread the cost over time.
The heat pump coil for your furnace
The CAPEA2418C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV6SA1810A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV6SA1810A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.