GOODMAN CAPEA3626B3 Evaporator A-Coil | 3 Tons
The Goodman CAPEA3626B3 3-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV7SA2410A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPEA3626B3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPEA3626B3: a narrow 3-ton coil that works all year round
A coil is not judged on a spec sheet, but over twelve months. The Goodman CAPEA3626B3 is a cased evaporator A-coil from the CAPEA line, with a nominal size of 3 tons (36,000 BTU/h). It runs on R-32 refrigerant and stands out for its 17-1/2 in wide cabinet, designed for furnaces that leave little room.
Let's see what it does, season by season, in a home in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, and then how it compares with its neighbours in the series.
Spring: the season of half measures
April and May are difficult months for a heating system. The morning is cool, the afternoon is mild, and the furnace starts up for only a few minutes. With a heat pump connected to this coil, heat is delivered in small doses, through the same ducts, without calling on the furnace. It is in these periods of mild weather that the heat pump shows its value best: it moves heat from outdoors to indoors rather than making it.
Summer: air conditioning and humidity
In July, heat is mostly a matter of humidity. The coil cools the air by passing it over cold surfaces; the water that condenses there is carried off by a 3/4 in FNPT drain, with one primary and one secondary outlet. The result: drier air, and so more comfortable at the same temperature.
At 3 tons, this model serves medium to large homes, with several bedrooms upstairs. We always validate this size with a load calculation, because an oversized system cools quickly but leaves the house clammy.
Fall: the ideal time to install
Homeowners rarely think about air conditioning in October, yet it is a good time to install: schedules are more flexible, the furnace is not yet running flat out, and the heat pump is ready for the first cold week. And since incentive eligibility depends on the installation date, it is better to talk about it early.
Winter: the furnace keeps its place
When the thermometer plunges, the heat pump's efficiency drops. That is normal, and it is why the furnace stays in place as backup heat. It takes over below a threshold that we program with you at start-up. The coil stays in the plenum and keeps distributing the heat from the heat pump whenever it is running.
What this model brings to your system
- Size: 3 tons (36,000 BTU/h).
- Width: 17-1/2 in; full dimensions of 17-1/2 × 26 × 21 in (width, height, depth).
- R-32 refrigerant, with a leak sensor designed for the service life of the coil.
- EEV expansion, electronic type.
- Piping connections: 5/16 or 3/8 in on the liquid side, 3/4 or 7/8 in on the suction side.
- Upflow or downflow positions; the DFKE-02 kit is required for the 4830 and 6030 models in downflow.
The matched outdoor unit: the GZV7SA2410A
The manufacturer publishes, for this coil, a match with the Goodman GZV7SA2410A heat pump. The system carries AHRI number 217589286 and shows 23,200 BTU/h in cooling, 23,200 BTU/h in heating at 47 °F, SEER2 19.0, HSPF2 8.6. This match is certified, and the R-32 Goodman matches in this heat pump family are described by the manufacturer as ENERGY STAR and cold climate certified.
Once again: the coil has no efficiency rating of its own. It is the ratings of the matched system that count when comparing two quotes.
B3, C3 or D3: three widths for the same capacity
The 3-ton CAPEA series includes three cabinet widths. All three share the same capacity, the same outdoor unit and the same system number:
- CAPEA3626B3: 17-1/2 in, for narrow furnaces;
- CAPEA3626C3: 21 in, for furnaces of intermediate width;
- CAPEA3626D3: 24-1/2 in, for wide furnaces.
The choice therefore rests only on the furnace. Against the 2.5-ton models (CAPEA3022B3, same width), the 3-ton B3 suits a home with heavier cooling demands. Against the 4-ton models, it suits a home where you are not looking for such a large airflow.
Why 3 tons is a common size for us
Many two-storey homes with a basement in the Montreal area fall naturally into this capacity range: three or four bedrooms, an open living room, a kitchen that heats up in summer. For these homes, 3 tons avoids both the strain of an undersized unit and the short cycles of an oversized one. We still confirm it by calculation, without relying on a general impression.
What the furnace must offer this coil
The coil depends on the blower: if the air does not circulate enough, it freezes up or loses performance. So we measure the airflow, inspect the filter and examine the duct network to spot sections that are too narrow or poorly insulated. A new coil on an unbalanced duct network will not deliver what is expected of it.
That is why we prefer to talk about a system, not a part: coil, outdoor unit, blower and ducts form a whole.
R-32 and the complete match
The coil is paired with an outdoor unit that uses the same refrigerant, which we install at the same time. If your current air conditioner is still in good condition, we will tell you; but, as a general rule, it cannot be reused with an R-32 coil.
Installation, step by step
- Measuring the furnace, checking the blower and the electrical panel.
- Coil installed in the plenum, connections to the ducts sealed, transition built as needed.
- Outdoor unit installed, piping brazed, nitrogen test, vacuum.
- Drain and thermostat connected.
- Commissioning, airflow adjustment, explanation of how it works.
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, and works under RBQ licence 5645-9605-01.
Manufacturer's warranty
Goodman provides a limited 10-year warranty on parts. Online registration within 60 days of installation is mentioned in the manufacturer's sheet; it is not required in Quebec.
To check before buying
- The outdoor unit must be R-32, like the coil.
- The published ratings apply to the certified match.
- The furnace must offer the right width and a blower capable of the required airflow; we confirm this at the visit.
LogisVert incentive
The matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list at the time of the quote, then prepare the application with you.
Request your estimate
Our visit is free: we measure the furnace, look at the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPEA3626B3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV7SA2410A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV7SA2410A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.