GOODMAN CAPEA3022C3 Evaporator A-Coil | 2.5 Tons
The Goodman CAPEA3022C3 2.5-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV6SA1810A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPEA3022C3
514 316-2973 · sales@airgreen.ca
Quick facts
A day with the CAPEA3022C3: from the basement to commissioning
Rather than run through a list of features, let's follow the Goodman CAPEA3022C3 from the preliminary visit to the first day of operation. This cased evaporator A-coil, 21 in wide, belongs to the 2.5-ton size (30,000 BTU/h) and uses R-32 refrigerant. It is designed for a somewhat wider furnace in a mid-sized home.
The homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who call us often share the same starting point: an old central air conditioner on its last legs, or an electric furnace they would like to back up with a heat pump.
Before the visit: what we ask you to prepare
Clear access to the furnace, locate the electrical panel and, if possible, photograph the appliance's label. Nothing more. The rest we measure ourselves. This avoids buying a cabinet based on a remembered set of dimensions.
Step one: the tape measure
We note the width of the furnace. If it matches the 21 in cabinet, installation is straightforward. If not, we build an insulated transition on site. The model's dimensions are 21 × 22 × 21 in (width, height, depth); its height of 22 in is the clearance to allow above the furnace, plenum included.
We also check the direction of airflow. The coil is installed in the upflow or downflow position; for the 4830 and 6030 models in downflow, the manufacturer publishes the DFKE-02 kit.
Step two: the load calculation
At 2.5 tons, the CAPEA3022C3 sits between the small and large sizes. It is chosen for a cottage whose upper floor is well insulated or for a bungalow whose basement is unfinished. We count the windows, assess the insulation and analyze the duct layout. If the numbers point to another size, we change models without pushing.
Step three: choosing the outdoor unit
Two certified matches are published for this coil:
- Goodman GZV6SA1810A, AHRI 217589357: cooling 17,000 BTU/h, heating 16,800 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.8;
- Goodman GZV7SA2410A, AHRI 217589284: cooling 23,200 BTU/h, heating 23,200 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.6.
The coil itself has no rating. It is these two AHRI numbers that describe a complete system, and any incentive application rests on them.
Installation day
In the morning, we protect the floor, cut power to the furnace and open the plenum. The cabinet is shimmed, sealed and insulated. The connections are 5/16 or 3/8 in on the liquid side and 3/4 or 7/8 in on the suction side; the piping is carefully brazed. The condensate drain, 3/4 in FNPT with one primary and one secondary outlet, gets its fitting and its route to a floor drain or a pump.
Outside, the outdoor unit takes its place on its pad or bracket. We carry out the nitrogen leak test, then pull a vacuum before opening the refrigerant. In the afternoon, the thermostat is connected.
Commissioning
We start up the whole system, measure the airflow, adjust the settings and check that the condensation drains properly. The coil's expansion valve is an EEV type, meaning electronic. The R-32 leak sensor, designed to last as long as the coil, is checked as well. Finally, we take the time to explain the thermostat and the threshold at which the furnace takes over from the heat pump.
Where this model sits in the series
- CAPEA3022B3: same capacity and same matches, but a narrow 17-1/2 in cabinet.
- CAPEA2418C3: same 21 in width, 2 tons, a single outdoor unit (GZV6SA1810A).
- CAPEA3626C3: same width, 3 tons, matched with the GZV7SA2410A.
If you are torn between two neighbours, bring us the dimensions of the furnace and the floor area served: the answer rarely comes down to anything else.
Two house scenarios for this size
First scenario: a cottage on the North Shore, recent windows, a well-insulated attic floor, a somewhat wide furnace inherited from an older, larger air conditioner. The 21 in cabinet fits without a transition, and the 2.5-ton size is enough to cool the upper floor without chilling the main floor too fast.
Second scenario: a bungalow in Longueuil with a half-finished basement. The ducts mostly serve the main level. Here, a larger system would be a bad calculation: it would shut off too soon and leave moisture in the air. In both cases, it is the on-site measurement that decides, not habit.
What is better not to improvise
Brazing, the nitrogen test and the vacuum are not decorative steps. They are what guarantees the circuit stays sealed for the life of the system. A poorly sealed joint in the plenum can also let treated air leak into the mechanical room: we check the joints by eye and by hand before closing up.
The same logic applies on the electrical side: we look at the panel before promising anything, because an outdoor unit needs its own circuit.
Warranty and refrigerant
The manufacturer offers a limited 10-year warranty on parts. Online registration within 60 days of installation is provided for in its sheet, but it is not required in Quebec. Because the coil runs on R-32, it is paired with an outdoor unit that uses the same refrigerant, installed along with it. An old air conditioner is generally not suitable.
The following winter
When the cold arrives, the heat pump takes the lead role. It moves heat from outdoors into your ducts; its efficiency drops with the temperature, and the furnace takes over below the threshold we programmed with you. For you, the gesture stays the same: turn the thermostat.
In summer, the same coil cools and dries the air. A single outdoor unit replaces the window air conditioners; cool air reaches every room through the same vents.
To confirm before signing
- R-32 refrigerant on both sides of the system.
- The quoted ratings: they apply to the certified match.
- The width of the furnace and the capacity of its blower, which we check at your home.
LogisVert incentive
The Goodman system matched with this coil is on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We read it from the official list at the time of the quote, then put the application together with you.
On to your estimate
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. Request a free estimate: we come to your home, measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPEA3022C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV6SA1810A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV6SA1810A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.