GOODMAN CAPEA6030C3 Evaporator A-Coil | 5 Tons

In stock

The Goodman CAPEA6030C3 5-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV7SA3610A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPEA6030C3

5 tons60,000 BTU/h nominal
21 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 217589305
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPEA6030C3
ManufacturerGoodman
Size5 tons
Width21 in
RefrigerantR-32
MeteringEEV
Outdoor unitGZV7SA3610A

CAPEA6030C3: 5 tons, 21 in wide, three outdoor units to choose from

At the top of the CAPEA line sits the 5-ton size. The Goodman CAPEA6030C3 is a cased evaporator A-coil rated at a nominal 60,000 BTU/h, running on R-32 refrigerant, in a cabinet 21 in wide. It is the model that offers the most freedom of matching in the series: three published outdoor units, with three distinct AHRI numbers.

It is meant for very large homes in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, as well as buildings with a high load: open volumes, large glazed areas, several levels. We rarely recommend it without a prior calculation, and we explain why below.

Three matches, three personalities

The manufacturer publishes the following systems for this coil:

  • GZV7SA3610A, AHRI 217589305: cooling 35,000 BTU/h, heating 35,000 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.5;
  • GZV9SA361CA, AHRI 216699918: cooling 34,200 BTU/h, heating 32,600 BTU/h at 47 °F, SEER2 19.0, HSPF2 9.2;
  • GZV9SA4810A, AHRI 217989208: cooling 46,000 BTU/h, heating 47,000 BTU/h at 47 °F, SEER2 18.0, HSPF2 9.0.

The first shows equal capacities in heating and cooling. The second shows, for heating, HSPF2 9.2, the highest rating of the three. The third offers the largest published capacity, with SEER2 18.0. Each serves a different home, and it is the visit that settles it.

Why so many choices?

Because a 5-ton size covers a wide range of situations. A very large but well-insulated home does not have the same needs as a more modest home with older windows. The coil is the same; the outdoor unit makes the difference in capacity, in efficiency rating and in behaviour in cold weather. We present the three options with the numbers in hand, and we tell you which one seems suited to your home.

A point about electricity

The larger the outdoor unit, the more it draws on the electrical entrance. Before signing, we look at the panel, the gauge of the supply and the room available for a dedicated breaker. It is an unspectacular check, but it avoids stalling a job at the last minute. Our electrical work is covered by our RBQ licence 5645-9605-01.

The airflow of a large system

A coil of this size needs a lot of air. The furnace blower must be able to supply it, and the ducts must carry it without choking. We measure the airflow, look at the main ducts and flag the sections that need rework. A new coil does not make up for a narrow network: better to know before the installation.

Dimensions and connections

The CAPEA6030C3 measures 21 × 30 × 21 in (width, height, depth). It connects with 3/8 in on the liquid side and 7/8 or 1-1/8 in on the suction side. The condensate drain is 3/4 in FNPT, with one primary and one secondary outlet. The position can be upflow or downflow; for the 4830 and 6030 models in downflow, the manufacturer provides the DFKE-02 kit, which applies directly to this one.

How to choose it compared with the other CAPEA models

  • CAPEA6030D3: same capacity, same three outdoor units, but 24-1/2 in wide.
  • CAPEA4830C3: same 21 in width, but 4 tons, with two matches.
  • The 2 to 3-ton models: meant for more modest-sized homes.

The 5-ton C3 is therefore the choice for a high load on a 21 in furnace. If the furnace is wider, it is its twin, the D3.

For which homes, precisely?

Picture a large cottage on the North Shore with a cathedral-ceiling room, a south-facing sunroom and a full floor above a finished basement. Or a residence in Laval that has been extended twice, where a single duct network now serves every room. In these homes, the load can justify a 5-ton size. But it can also fit in a smaller size if the building envelope has been renovated: the calculation decides.

When a home is too large for a single system, we also bring up the option of two separate systems, one per zone. It is not always necessary, but it is worth the discussion.

What happens in the middle of summer

A 5-ton size that runs in cycles that are too short does not dry the air: that is why we refuse to oversize. In a home where the load truly justifies this size, on the other hand, the system runs long, steady cycles, the air is dehumidified, and the temperature stays stable from room to room.

What the coil does in the system

It receives the refrigerant from the outdoor unit, lets it evaporate in its tubes and picks up heat from the air passing through. The condensation water runs to the pan, then out the drain. With a heat pump, the cycle reverses in winter and the coil becomes the source of heat in the ducts. The furnace keeps its blower and its backup role; it takes over below a threshold that we set with you. The coil's expansion valve is an EEV type.

R-32, sensor and warranty

The coil uses R-32 and must be matched with an outdoor unit that uses the same refrigerant, installed at the same time. It includes a leak sensor designed to last as long as the coil. The manufacturer offers a limited 10-year warranty on parts; online registration within 60 days of installation is not required in Quebec.

The installation, in order

  • Measuring the furnace, checking the blower and the electrical panel.
  • Coil installed in the plenum, duct connections sealed, transition if needed.
  • Outdoor unit on a pad or bracket, piping brazed, nitrogen test, vacuum.
  • Drain and thermostat connected.
  • Commissioning, airflow adjustment, walkthrough for the household.

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years.

To check before ordering

  • R-32 refrigerant on both sides.
  • Quoted ratings: they apply to the certified match chosen.
  • Furnace width, blower capacity, condition of the ducts, electrical entrance.

LogisVert incentive

The matched Goodman system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We read it from the official list at the time of the quote and put the application together with you.

Request your estimate

Our estimate is free and done on site: measurement of the furnace, check of the electrical entrance, written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPEA6030C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV7SA3610A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Goodman GZV7SA3610A outdoor unit
Certified systemMatched with the GZV7SA3610A, the system carries AHRI 217589305.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPEA6030C3
TypeCased evaporator coil
LineCAPEA
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-32
Metering deviceEEV
Liquid connection3/8 in
Suction connection7/8 or 1-1/8 in
Dimensions W × H × D21 × 30 × 21 in
Matched outdoor unitGZV7SA3610A, GZV9SA361CA, GZV9SA4810A
System AHRI number217589305, 216699918, 217989208
System SEER2 / HSPF219.0 / 8.5
Model numberCAPEA6030C3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.