GOODMAN CAPFA1818A3 Evaporator A-Coil | 1.5 Tons

In stock

The Goodman CAPFA1818A3 1.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA1818A3

1.5 tons18,000 BTU/h nominal
14 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA1818A3
ManufacturerGoodman
Size1.5 tons
Width14 in
RefrigerantR-32
MeteringPiston

CAPFA1818A3: the 1.5-ton Goodman coil that fits a narrow 14 in furnace

In many Montreal basements, the furnace sits in a tight corner between the water heater, a concrete wall and a row of pipes. If that sounds like your home, the width of the coil matters as much as its capacity. The Goodman CAPFA1818A3 is the narrowest of the 1.5-ton coils in the line: 14 in wide, in an insulated cabinet, with R-32 refrigerant.

On this page, we explain what it is for, how it is matched, what we check at your home before ordering, and how it differs from its neighbours in the series. Our crews install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What an evaporator coil does, in plain terms

The unit installed outside does not make cold air on its own. The cooling happens inside, in the coil: a network of tubes and fins where the refrigerant evaporates and absorbs heat from the air passing around it. That air, cooled and dried, goes back through the ducts to every room.

The CAPFA1818A3 sits on top of the furnace or on a blower cabinet. Air already flows through your home's ducts; the coil simply sits in its path.

A narrow furnace, a small system

The 1.5-ton size corresponds to a nominal 18,000 BTU/h. It is a size for modest spaces: a condo with a furnace, a plex unit, or a small, well-insulated house. We recommend it only after calculating the home's load, never at a glance.

Why be careful with small sizes? Because a unit that is too big shuts off before it has dried the air. You get a room that is cool but clammy. A unit of the right size runs longer and more gently, and the house stays dry.

The actual dimensions of the cabinet

  • width: 14 in;
  • height: 18 in;
  • depth: 21 in;
  • liquid line connection: 3/8 in, suction line connection: 3/4 in;
  • condensate drain: 3/4 in FNPT, primary and secondary.

Grab a tape measure and look at the plate on your furnace. If the width of the outlet plenum is close to 14 in, this model goes in with almost no adaptation. If not, we build an insulated transition on site.

Why choose this model over its neighbours

The CAPFA series comes in nine models that share the same line, the same R-32 refrigerant and the same piston as the metering device. Only two things change: capacity and width.

  • CAPFA1818B3: same 1.5-ton capacity, but 17-1/2 in wide. It suits a slightly wider furnace.
  • CAPFA1818C3: same capacity, 21 in wide, for large cabinets.
  • CAPFA2422A3: the same 14 in width as this one, but 2 tons and a taller cabinet than this one.
  • CAPFA3022A3: the same 14 in width, but 2.5 tons.

In other words, if your furnace is narrow and the house needs more than 1.5 tons, the series offers variants of the same width. If the house needs 1.5 tons and the furnace is wider, a 17-1/2 in or 21 in sibling will be simpler to install.

A-coil shape, cabinet and piston metering device

The coil is A-shaped: two sloped faces that meet at the top. Air rises through the centre and passes through both planes. The insulated cabinet comes with the coil, which limits air leaks and speeds up the installer's work.

The metering device is a piston: a small calibrated part that doses the refrigerant entering the coil. The installation positions published by the manufacturer are upflow and downflow. An R-32 refrigerant leak detection sensor, designed to last as long as the coil, is listed in the model's specification sheet.

Add-on heat pump: keep the furnace, add the heat pump

Many homeowners have an electric furnace and ductwork in good condition. The coil lets them move to a central heat pump without redoing the air distribution. The blower, the filters and the ducts are all kept.

In summer, the system cools. In winter, with a heat pump, the cycle reverses and heat from outdoors is brought into the house. When the outdoor temperature drops below the threshold we set with you, the furnace takes over as backup heat.

With a central air conditioner only, the coil provides cooling and nothing more. So it helps to know, before the quote, what you want: cooling only, or heating as well.

Matching with the outdoor unit

The coil must be matched with a Goodman outdoor unit of the same capacity and the same refrigerant. It has no efficiency rating of its own: the SEER2, EER2 and HSPF2 ratings belong to the certified system, linked by an AHRI number. Before ordering, we confirm that number, so the performance promised is the performance you get.

One practical point: an old air conditioner that uses a different refrigerant is generally not kept. The R-32 coil and the outdoor unit are installed together.

  • No R-32 match with this coil is listed by ENERGY STAR; check the AHRI directory for the outdoor unit you choose;
  • 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).

Our visit and our installation, step by step

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, operating under RBQ licence 5645-9605-01. Here is the usual sequence:

  • we measure the furnace and check the blower and the electrical panel;
  • we set the coil in the plenum, with a transition if needed, and seal the connections;
  • we install the outdoor unit on a pad or bracket, braze the piping, pressure-test with nitrogen and then pull a vacuum;
  • we connect the condensate drain and the thermostat;
  • we commission the system, set the airflow and explain how it works.

What you should check before buying

  • Does the furnace have a plenum about 14 in wide? If not, a transition will be needed.
  • Is the blower able to deliver the system's airflow?
  • Do you want cooling only, or heating as well?
  • Is the outdoor unit you chose on the same refrigerant, R-32?

A real-world example: the South Shore plex

Picture a ground-floor unit in a plex in Longueuil. The furnace, installed in a utility closet, has very little side clearance. The owner wants air conditioning in July and, if possible, a lower heating bill in February. In a situation like this, a narrow 1.5-ton coil avoids moving the furnace or redoing the ducts. That is exactly what the CAPFA1818A3 is for.

By contrast, in a large house in Laval or on the North Shore, we would lean toward a higher capacity. The heating and cooling load, calculated room by room, settles the question, not habit.

Incentives

Incentives depend on the complete system, not on the coil alone. We check Hydro-Québec's official list against your installation date and tell you what applies to your project.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA1818A3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA1818A3
TypeCased evaporator coil
LineCAPFA
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D14 × 18 × 21 in
Model numberCAPFA1818A3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.