GOODMAN CAPFA2422C3 Evaporator A-Coil | 2 Tons
The Goodman CAPFA2422C3 2-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA2422C3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CAPFA2422C3: common myths and straight answers for a 2-ton, 21 in coil
When you are getting ready to buy a heat pump or a central air conditioner, you run into a lot of half-truths. The CAPFA2422C3, a Goodman 2-ton coil with a 21 in cabinet, is a good excuse to take them apart one by one. The answers below rely on the manufacturer's data sheet and on our installation experience in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
"A bigger coil always cools better"
False. Capacity is chosen according to the load of the house, not according to the size of the cabinet. A unit that is too big shuts off before it has removed the moisture from the air; the room is cool, but clammy. The 2-ton model (24,000 BTU/h) is right when the calculation supports it, and that is all.
"Width tells you the capacity"
No more than that. In the CAPFA series, three widths exist, 14 in, 17-1/2 in and 21 in, and each width comes in three capacities. The C3 is the wide version: it fits large-cabinet furnaces, whatever capacity is selected. Its height is 22 in and its depth is 21 in.
"A coil has its own efficiency rating"
No. The SEER2, EER2 and HSPF2 ratings relate to a certified system: one specific coil, one specific outdoor unit, one AHRI number. When you compare two quotes, that is the number to ask for. We confirm it before ordering.
"I can keep my old air conditioner"
Almost never. This coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer, of the same capacity and the same refrigerant. We therefore install the complete system. No R-32 match with this coil is listed by ENERGY STAR; we consult AHRI for the unit selected.
"It only cools"
Paired with a central air conditioner, yes. But with a heat pump, the same coil is used for heating: the cycle reverses and heat from outdoors is transferred to the air in the house. The furnace stays there for the coldest days, according to a temperature threshold that we set with you.
"My furnace is not the right width, so it's impossible"
That is not an obstacle. We measure the furnace and, if needed, build an insulated transition on site. With the C3, however, this situation is less common if your cabinet is wide.
Where the C3 sits among its neighbours
- CAPFA2422A3: 2 tons, 14 in;
- CAPFA2422B3: 2 tons, 17-1/2 in;
- CAPFA1818C3: 21 in as well, but 1.5 tons;
- CAPFA3022C3: 21 in as well, but 2.5 tons.
All share R-32, the piston metering device and installation in the upflow or downflow position.
What the specification sheet contains
- type: cased A-coil;
- nominal size: 2 tons (24,000 BTU/h);
- dimensions (W × H × D): 21 × 22 × 21 in;
- connections: 3/8 in liquid and 3/4 in suction;
- condensate drain: 3/4 in FNPT, primary and secondary;
- leak detection: R-32 sensor designed to last for the life of the coil;
- warranty: 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).
How we work
We are a family-owned heating and cooling company based in Montreal for more than fifteen years, and our work is covered by RBQ licence 5645-9605-01.
- Measuring the furnace, checking the blower and the electrical panel.
- Installing the coil in the plenum, sealing the connections.
- Installing the outdoor unit, brazing, nitrogen test, vacuum.
- Connecting the drain and the thermostat.
- Commissioning and airflow adjustment.
Before you decide
- Measure the plenum: about 21 in wide?
- Check that the clear height above the furnace accepts a 22 in cabinet.
- Ask for the AHRI number of the complete system.
- Say whether you also want heating.
"Incentives apply to the coil"
This is a common confusion. The programs target the complete system, not an isolated part. A coil alone does not qualify for assistance: it is the coil and outdoor unit together, with their AHRI number, that is reviewed. We therefore check the official list against the installation date before giving you the quote.
"Once it's installed, you never touch it again"
Almost. A well-installed coil needs little, but three habits help. Change the furnace filters regularly, because clogging reduces airflow. Look at the condensate drain from time to time: standing water near the cabinet points to a blockage. Have the system checked by a technician now and then, especially before summer.
"A heat pump doesn't work in Quebec's cold"
It does lose efficiency when it gets very cold, that is true, and that is exactly why the furnace stays in place. The add-on setup shares the work: the heat pump supplies heat when temperatures are moderate, and the furnace takes over below a threshold that we set with you, based on your house. Both run on the same blower and the same ducts.
"All installers do it the same way"
The steps are well known, but the execution varies. Brazing the piping under nitrogen, the pressure test, the vacuum and the airflow adjustment are steps we never skip. They cannot be seen once the cabinet is closed, but they determine the life of the system.
A typical visit in Greater Montreal
We come to your home with a tape measure and a flashlight. We open the furnace, note the model, measure the width and depth of the plenum and record the clear height. Then we go look at the electrical panel and the spot planned for the outdoor unit: sheltered from snow sliding off the roof, clear on each side, with a stable base.
The visit takes little time, but it shapes everything else. Once the measurements are taken, we can confirm the coil model, the match and the AHRI number, then give you a clear written quote.
The role of the piston metering device
This coil uses a piston to dose the refrigerant. It is a calibrated orifice, with no moving part and no electronics. Its simplicity makes it a reliable component, but it requires that the coil and the outdoor unit be properly matched, hence the importance of the AHRI number and of a careful vacuum.
When another model would be preferable
If the furnace is narrow, a slimmer model, such as the 14 in CAPFA2422A3 or the 17-1/2 in CAPFA2422B3, avoids a large transition. If the house needs a different capacity, the series offers two others with the same 21 in width: the CAPFA1818C3 and the CAPFA3022C3. We always prefer to steer you toward the model that is simplest to install, not the biggest.
Incentives
Incentives depend on the complete system. We check Hydro-Québec's official list against the installation date and tell you what applies.
Estimate and financing
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA2422C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.