GOODMAN CAPFA1818B3 Evaporator A-Coil | 1.5 Tons
The Goodman CAPFA1818B3 1.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA1818B3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CAPFA1818B3: 1.5 tons, 17-1/2 in, for a mid-width furnace
Before talking about capacity or refrigerant, let's start with a simple step: open the door of your furnace, find the warm-air outlet and measure its width. That number guides the choice of an evaporator coil more often than people think. Goodman's CAPFA1818B3 is aimed at furnaces whose plenum is about 17-1/2 in, neither the narrowest nor the widest in the series.
It is a cased A-coil, rated at 1.5 tons, using R-32 refrigerant. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, together with the matching Goodman outdoor unit.
Where it sits in the series
Goodman offers the CAPFA line in three widths and three capacities. This model takes the middle slot for width and the smallest column for capacity.
- The CAPFA1818A3 is its 14 in twin, for narrow furnaces.
- The CAPFA1818C3 is its 21 in twin, for wider cabinets.
- The CAPFA2422B3 keeps the 17-1/2 in width, but moves up to 2 tons.
- The CAPFA3022B3 keeps that width too, with 2.5 tons.
The point to remember: width answers the question "will it fit on my furnace?" and capacity answers "is it enough for my house?" Two separate questions, two separate decisions.
The 1.5-ton size, used wisely
A nominal 18,000 BTU/h size suits a compact home, a condo, one floor of a plex or a small, well-insulated house. Before proposing it, we calculate the load. An oversized system short-cycles: it cools without drying, and the humidity stays in the rooms.
A unit sized as closely as possible runs in long, quiet cycles. Temperature differences between rooms shrink, and the noise of start-ups becomes less frequent.
Specification summary
- model: CAPFA1818B3, CAPFA line;
- type: cased evaporator coil;
- nominal size: 1.5 tons (18,000 BTU/h);
- refrigerant: R-32;
- dimensions (W × H × D): 17-1/2 × 18 × 21 in;
- liquid line connection 3/8 in, suction line connection 3/4 in;
- condensate drain: 3/4 in FNPT, primary and secondary;
- metering device: piston;
- positions: upflow or downflow;
- manufacturer's warranty: 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).
The manufacturer also states that an R-32 leak detection sensor is designed to last for the life of the coil.
How air moves through the coil
Picture two sloped plates shaped like a roof. Air from the blower rises, meets these two faces and comes out cooled. The water that condenses on the fins drops into a pan and flows out through the drain; a second drain connection acts as a safeguard if the first one clogs.
The piston sets the flow of refrigerant into the coil. It is a simple part, with no electronics, calibrated for the capacity of the model.
A coil for the heat pump, not only for air conditioning
Paired with a central air conditioner, it cools the house in summer. Paired with a heat pump, it does the reverse in winter: the refrigerant warmed outdoors gives up its heat to the air in the house. The existing ducts serve in both seasons.
- turn an electric furnace into a central heat pump;
- replace an old central air conditioner with a new system;
- keep the furnace as backup for the coldest days.
The temperature threshold at which the furnace takes over is set with you at commissioning.
An example: the Laval bungalow
Take a Laval bungalow whose electric furnace is several decades old. The owner wants cool air in summer and help with heating in winter, without running new ducts. The air outlet measures about 17-1/2 in: the CAPFA1818B3 goes straight on, with no transition. The existing ducts, blower and filters keep doing their job.
If the same house had a narrower furnace, we would have looked at the A3. If it had a large 21 in furnace, it would be the C3. Width dictates the model; load dictates the capacity.
Measuring without mistakes
A common mistake is to measure the outside width of the furnace rather than that of the plenum. The two are not the same. What counts is the opening the cabinet will sit on. During our visit, we take that measurement, note the height available above it and mark the location of the drain and the outlet to the outdoors.
The cabinet of this model is 21 in deep, which must also match the depth of the furnace. When both dimensions agree, installation is quick and the seal is very good. When they differ slightly, an insulated transition built on site solves the problem.
What winter asks of the furnace
A heat pump loses efficiency when the outdoor temperature drops. That is why the furnace stays in place as backup: it takes over below the threshold we program together. That threshold is not a universal constant; it depends on your house, its insulation and your habits. We adjust it at commissioning and can revisit it after a first winter.
What must stay matched: the pairing
The coil and the outdoor unit form one system. They must share the same refrigerant and a capacity at the same level. The efficiency ratings, SEER2, EER2 and HSPF2, belong to this matched system and to the AHRI number that identifies it, never to the coil alone. We confirm that number before the order.
A useful note: no R-32 match with this coil is listed by ENERGY STAR; AHRI remains the reference for the outdoor unit you choose.
Our installation method, from measurement to commissioning
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, operates under RBQ licence 5645-9605-01.
- Visit: measuring the furnace, the blower and the electrical panel.
- Coil: installed in the plenum, with an insulated transition if the width differs, and sealed connections.
- Outdoor unit: pad or bracket, brazed piping, nitrogen test, vacuum.
- Finishing: condensate drain, thermostat, airflow adjustment.
- Handover: an explanation of how it works, and answers to your questions.
Five checks to make before signing
- Is the width of the furnace outlet close to 17-1/2 in?
- Can the blower deliver the required airflow?
- Does the electrical panel accept the outdoor unit?
- Is R-32 indeed the refrigerant of the complete system?
- Do the incentives you are aiming for apply to this match?
The coil and air quality
A cold coil condenses moisture from the air, but it does not filter dust. That job belongs to the furnace, with its filter. Keeping a clean filter therefore helps the coil stay clean and the airflow stay steady. We show you where it is and how to replace it.
Incentives
Eligibility for Hydro-Québec programs is judged on the complete system. We check the official list against the installation date and tell you what applies.
Let's talk about your project
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA1818B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.