GOODMAN CAPFA3022B3 Evaporator A-Coil | 2.5 Tons

In stock

The Goodman CAPFA3022B3 2.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA3022B3

2.5 tons30,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA3022B3
ManufacturerGoodman
Size2.5 tons
Width17-1/2 in
RefrigerantR-32
MeteringPiston

Goodman CAPFA3022B3: 2.5 tons and 17-1/2 in, compared with its eight neighbours in the series

Choosing an evaporator coil from a series of nine models is a bit like choosing a key from a keyring. They all look alike, but only one opens the right door. The CAPFA3022B3 is the one you need when the furnace has a plenum of about 17-1/2 in and the house calls for a nominal 2.5 tons of capacity, or 30,000 BTU/h. Here is how to place it.

The series chart, in words

Goodman's CAPFA line crosses three widths with three capacities. All the models share the same R-32 refrigerant, the same piston metering device and the same 3/8 in and 3/4 in connections.

  • 1.5-ton capacity: CAPFA1818A3 (14 in), CAPFA1818B3 (17-1/2 in), CAPFA1818C3 (21 in).
  • 2-ton capacity: CAPFA2422A3 (14 in), CAPFA2422B3 (17-1/2 in), CAPFA2422C3 (21 in).
  • 2.5-ton capacity: CAPFA3022A3 (14 in), CAPFA3022B3 (17-1/2 in), CAPFA3022C3 (21 in).

The letter in the middle of the model number indicates the width: A for the narrowest, B for the mid-width and C for the widest. The CAPFA3022B3 is therefore the B width of the highest capacity.

Two questions to find the right model

First question: what is the width of your plenum? Measure it, or let us do it. Second question: what capacity does your house need? A load calculation answers that, not an impression.

Once you have those two answers, the model follows. If the furnace is 17-1/2 in wide and the calculation gives 2.5 tons, it is the 3022 B3. If the calculation gives 2 tons, it is the CAPFA2422B3. If the calculation gives 1.5 tons, it is the CAPFA1818B3.

The cabinet in numbers

  • width: 17-1/2 in;
  • height: 22 in;
  • depth: 21 in;
  • type: cased coil, A shape;
  • positions: upflow or downflow;
  • condensate drain: 3/4 in FNPT, primary and secondary.

The manufacturer also provides an R-32 leak detection sensor designed to last for the life of the coil. The limited warranty is 10 years on parts, with online registration within 60 days of installation (not required in Quebec).

A year in the life of this coil

June to August: the coil cools and dries the air throughout the house, and the collected water goes down the drain. September and October: with a heat pump, the same unit gently warms the house. November to March: when the cold turns sharp, the furnace takes over from the threshold set with you. April and May: the heat pump takes the controls again.

This calendar is not rigid. It depends on the house and its insulation. It simply shows how the heat pump and the furnace complement each other in an add-on setup.

Why not keep the old air conditioner?

Because an R-32 coil requires an outdoor unit designed for this refrigerant and of the same capacity. The SEER2, EER2 and HSPF2 ratings do not belong to the coil but to the certified system and its AHRI number. No R-32 match with this coil is listed by ENERGY STAR, so we consult AHRI for the outdoor unit selected.

AirGreen's work, from A to Z

AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. We install this coil in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

  • visit, measurements, checking the blower and the panel;
  • installing the cabinet, insulated transition if needed, sealing the connections;
  • outdoor unit on a pad or bracket, brazing, nitrogen test, vacuum;
  • drain and thermostat;
  • commissioning, airflow adjustment, explanations.

Mistakes to avoid

  • Choosing the capacity based on the size of the cabinet rather than on the load.
  • Measuring the outside of the furnace instead of the plenum opening.
  • Forgetting to check the clear height for a 22 in cabinet.
  • Comparing quotes without asking for the AHRI number.
  • Matching an R-32 coil with another refrigerant.

A visit to your home, step by step

We start with the furnace: model, age, rating plate, condition of the blower. We then measure the air outlet to confirm the 17-1/2 in width and check the 21 in depth. We look at the height available for the 22 in cabinet, then at the location of the drain and the route of the piping to the outdoor unit.

The outdoor unit needs space around it and a stable surface. We avoid spots where snow piles up or where defrosting could interfere with operation. Once these points are validated, we prepare the quote.

The role of the piston in the series

The piston is a calibrated orifice that doses the refrigerant entering the coil. It has no electronics. On every model in the line, it plays the same role. That is why you should not swap one coil for another at random: each model has its own size.

The coil, one part among others

In a well-designed system, nothing stands alone. The blower must move the right volume of air, the ducts must distribute it well, the outdoor unit must have the right capacity and the thermostat must control the whole. The coil is only one of these parts, but it is the one that decides how much heat and moisture is removed from the air.

Before signing

Make sure the blower can deliver the system's airflow, that the electrical panel is ready for the outdoor unit and that the match is confirmed in writing. These are three simple points that avoid surprises.

Why a local installer makes the difference

A coil can be ordered online in a few clicks, but installing it takes craft: clean brazing, pressure test, vacuum, airflow adjustment. At AirGreen, these steps are done by our own crews. If an adjustment is needed after commissioning, we are close by, on the island of Montreal, in Laval, in Longueuil and on both shores.

We also give you a clear explanation of how it works, which filters to maintain and which drain to watch. A system you understand is a system you maintain better.

What happens if the house changes

A house evolves: a room is added, the attic is insulated, the windows are replaced. Each change alters the cooling and heating load. If you are planning work, mention it at the visit. We calculate the capacity taking into account the future state of the house, not only its current state, to avoid choosing a size you will regret in a few years.

Incentives

Incentives depend on the complete system. We check Hydro-Québec's official list against the installation date, then explain what applies.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA3022B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA3022B3
TypeCased evaporator coil
LineCAPFA
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 22 × 21 in
Model numberCAPFA3022B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.