GOODMAN CAPFA3022C3 Evaporator A-Coil | 2.5 Tons
The Goodman CAPFA3022C3 2.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA3022C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPFA3022C3: the largest cabinet in the CAPFA series, 2.5 tons and 21 in wide
In Goodman's CAPFA series, the CAPFA3022C3 takes the top-right corner of the chart: the highest capacity, 2.5 tons or a nominal 30,000 BTU/h, with the greatest width, 21 in. It is aimed at larger homes or those with greater cooling demands, equipped with a furnace that has a generous cabinet. Here is what to know before choosing it.
Who is a coil this size for?
For a house whose cooling load, calculated room by room, exceeds that of a 2-ton size. A bungalow with west-facing glass, a North Shore cottage with a big living room, a Laval house with a finished basement and well-insulated attic: each one makes different demands, and the calculation sorts them out.
We insist on the calculation because too much capacity does as much harm as too little. The system short-cycles, the humidity stays, and the promised comfort does not show up.
How the coil works
In the furnace plenum, the warm air of the house passes over the two sloped faces of the A-coil. The cold R-32 refrigerant evaporates in the tubes and absorbs heat. The cooled air goes back out through the ducts. The water removed from the air is collected in the pan and flows out through the drain.
With a heat pump, the cycle reverses in winter. The refrigerant warmed outdoors gives up its heat to the air in the house through this same coil. The furnace remains the backup for the coldest days.
Comparing the 3022 C3 with its direct neighbours
- CAPFA3022B3: the same 2.5-ton capacity, but 17-1/2 in wide;
- CAPFA3022A3: the same capacity, but 14 in wide;
- CAPFA2422C3: the same 21 in width, but 2 tons;
- CAPFA1818C3: the same width, but 1.5 tons, with a lower cabinet.
If your furnace is narrower, do not force it: a model of lesser width, or an insulated transition, will be simpler than a cabinet that is too wide.
Dimensions and connections
- W × H × D: 21 × 22 × 21 in;
- liquid line connection: 3/8 in;
- suction line connection: 3/4 in;
- condensate drain: 3/4 in FNPT, primary and secondary;
- metering device: piston;
- positions: upflow or downflow.
The plenum must offer an opening of about 21 in. We also check the available height, because the cabinet rises to 22 in.
Safety, warranty and refrigerant
R-32 is a recent-generation refrigerant. Goodman provides for this coil a leak detection sensor designed to last for the life of the coil. The manufacturer offers a 10-year limited parts warranty, with online registration within 60 days of installation, a formality not required in Quebec.
A system, not a part
A coil carries no efficiency rating. The SEER2, EER2 and HSPF2 values describe the certified system: coil, outdoor unit and the AHRI number that links them. To compare two quotes, ask for that number. We confirm it before the order.
The coil is matched with a Goodman outdoor unit of the same capacity and the same refrigerant. No R-32 match with this coil is listed by ENERGY STAR; we check AHRI for the unit selected.
What this setup changes in a large house
In a spacious house, the ducts run longer distances. The blower must therefore be able to push the system's airflow out to the farthest rooms. This is one of the points we check at the visit. If the blower is marginal, we tell you frankly and propose options.
The coil makes it possible to reuse the entire existing network. That avoids opening up walls and ceilings, which is a considerable advantage in a renovation.
Our work
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01, in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
- measuring the plenum, checking the blower and the electrical panel;
- installing the cabinet, sealing the duct connections;
- outdoor unit, brazing, nitrogen pressure test, vacuum;
- connecting the drain and the thermostat;
- commissioning, airflow set, demonstration.
Questions to ask yourself
- Is my plenum about 21 in wide?
- Do I have enough height for a 22 in cabinet?
- Does my load calculation justify 2.5 tons?
- Do I want heating in addition to cooling?
- Can my blower serve the whole house?
The wide cabinet, for a clean installation
A cabinet 21 in wide fits large plenums without reduction. There are fewer transition pieces, fewer joints to seal and less risk of air leaks. The duct connections are sealed with care, then the insulated cabinet is checked to make sure no gap remains.
This simplicity of installation is an asset for larger homes, where the slightest sealing defect costs you in comfort and noise.
Quebec winters: sharing the roles
When it is mild, the heat pump supplies most of the heat. When the cold hardens, its efficiency drops, and the furnace takes over according to the threshold we set with you. In a large house, this threshold is a real topic of discussion: it depends on insulation, orientation, window size and your habits. We set it at commissioning and are glad to revisit it after a first winter.
What does not change from one model to another
Despite their differences in width and capacity, all the coils in the line share the same philosophy: an insulated cabinet delivered with the coil, an A shape, a piston, R-32 refrigerant and a leak sensor. The choice therefore comes down mainly to two criteria, the width of your plenum and the capacity your house needs.
What you receive with our quote
Our written quote specifies the exact model of the coil, the matched outdoor unit, the system's AHRI number, the work included and the items to plan for, such as a possible electrical upgrade. It also indicates whether the project is likely to qualify for assistance, according to the official list and the installation date.
Nothing in it is vague. If a measurement is missing, we take it before writing the document, not after.
And if your furnace is narrower?
A 21 in cabinet on a narrower plenum would require a custom transition. It is doable, but it is not always the simplest. Depending on the real width of the furnace, a 2.5-ton model of lesser width, the CAPFA3022B3 or the CAPFA3022A3, will sometimes be better suited, at the same capacity.
Incentives
Incentives depend on the complete system, not on the coil alone. We check Hydro-Québec's official list against the installation date and tell you what applies to your project.
Estimate and financing
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA3022C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.