GOODMAN CAPFA2422B3 Evaporator A-Coil | 2 Tons
The Goodman CAPFA2422B3 2-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPFA2422B3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPFA2422B3: the 2-ton, 17-1/2 in Goodman coil, from the visit to commissioning
Rather than drawing up a list of features, let's follow the path of a homeowner who chooses the Goodman CAPFA2422B3: a cased evaporator A-coil, rated at 2 tons, 17-1/2 in wide, using R-32 refrigerant. At each step, we explain what happens and what you can check.
Step one: the visit and the measurements
We arrive at your home, in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, with a tape measure, a flashlight and a tablet. We look at the furnace or the blower cabinet, measure the air outlet and note the rating plate. We also check the electrical panel, because the outdoor unit needs a suitable circuit.
If the air outlet is about 17-1/2 in wide, this model fits without a transition. If there is a gap, we note it and plan for an insulated transition built on site.
Step two: the right capacity
A 2-ton size equals a nominal 24,000 BTU/h. It sits in the middle of the series, between 1.5 and 2.5 tons. It is a common capacity for a mid-sized house, but we confirm it with a load calculation, not a rule of thumb.
The aim is to avoid the extremes. Too small, and the system struggles on hot days. Too big, and it short-cycles and lets humidity settle in. A careful calculation avoids both.
Step three: the certified match
Before ordering, we choose the Goodman outdoor unit of the same capacity and the same refrigerant, then verify the system's AHRI number. The coil alone has no efficiency rating: the SEER2, EER2 and HSPF2 ratings belong to the certified match.
No R-32 match with this coil is listed by ENERGY STAR. We therefore rely on the AHRI directory for the outdoor unit selected.
Step four: installation day
- the coil and its insulated cabinet are set on the furnace plenum;
- the duct connections are sealed to prevent air leaks;
- the outdoor unit is installed on a pad or bracket;
- the copper piping is brazed, nitrogen-tested and then put under vacuum;
- the condensate drain and the thermostat are connected.
The coil's liquid line connection is 3/8 in and the suction line connection is 3/4 in. The 3/4 in FNPT drain has a primary outlet and a secondary outlet.
Step five: commissioning
We start the system, measure the airflow, set the thermostat and, in the case of a heat pump, program the threshold at which the furnace takes over. We then show you where the filters, the drain and the controls are.
What is particular about this model
The B3 is the middle width of the CAPFA series. Here is what separates it from its neighbours:
- CAPFA2422A3: the same capacity, but 14 in wide;
- CAPFA2422C3: the same capacity, but 21 in wide;
- CAPFA1818B3: the same 17-1/2 in width, but 1.5 tons;
- CAPFA3022B3: the same width, but 2.5 tons.
The cabinet measures 17-1/2 × 22 × 21 in. The 22 in height is the same as that of the 2-ton and 2.5-ton models in the series.
CAPFA2422B3 specification sheet
- type: cased evaporator coil, CAPFA line;
- size: 2 tons (24,000 BTU/h);
- refrigerant: R-32;
- metering device: piston;
- positions: upflow or downflow;
- leak detection: R-32 sensor designed to last for the life of the coil;
- manufacturer's warranty: 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).
Cooling only, or heating as well?
With a central air conditioner, the coil cools the air in summer and nothing more. With a heat pump, it becomes part of a system that cools and heats. The common cases: turning an electric furnace into a heat pump, replacing an old air conditioner, keeping the furnace as backup for the coldest days. The existing blower, filters and ducts stay in service.
To check before buying
- Plenum width close to 17-1/2 in.
- Blower able to deliver the required airflow.
- Same refrigerant, R-32, for the coil and the outdoor unit.
- Match and AHRI number confirmed.
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, operates under RBQ licence 5645-9605-01.
Frequently asked questions about the CAPFA2422B3
Can this coil provide heat?
Yes, when it is paired with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.
Can my current air conditioner stay in place?
In general, no. The coil runs on R-32 and must be paired with the outdoor unit specified by the manufacturer. We install the complete system in a single visit.
What if my furnace is not the right width?
We measure it and, if needed, build an insulated transition on site. This solution is common and does not compromise the seal when it is done properly.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature falls below the threshold we program with you. It also keeps moving the air for cooling.
What is the leak sensor for?
R-32 is a newer-generation refrigerant. The sensor specified by Goodman monitors for refrigerant in the cabinet throughout the life of the coil, a safety feature added by the manufacturer.
Why we like the mid-width
A width of 17-1/2 in leaves some room to manoeuvre. It connects well to furnaces of common size and leaves room to seal the joints with care. When a transition is needed, it stays modest and easy to insulate. It is a compromise between the slim 14 in cabinet and the large 21 in cabinet.
For a homeowner in Longueuil or on the North Shore who is torn between two widths, we compare both widths directly against the furnace's air outlet. Nothing replaces that check on site.
Everyday comfort
A system of the right capacity runs longer at low speed, which reduces temperature swings between rooms. The air coming out of the registers is drier in summer, and start-up noise is less noticeable. These gains depend much more on an accurate load calculation and proper airflow adjustment than on the brand of the coil.
One last tip: compare quotes on equal terms
If you receive several offers, check that each one lists the exact model of the coil, that of the outdoor unit and the AHRI number. Also ask what is included: brazing, nitrogen test, vacuum, drain connection. Two prices can look different when they do not cover the same work.
Incentives
Eligibility for Hydro-Québec programs depends on the complete system. We consult the official list against the installation date and tell you what applies to your project.
Next step: your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPFA2422B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
