GOODMAN CAPFA1818C3 Evaporator A-Coil | 1.5 Tons

In stock

The Goodman CAPFA1818C3 1.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPFA1818C3

1.5 tons18,000 BTU/h nominal
21 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPFA1818C3
ManufacturerGoodman
Size1.5 tons
Width21 in
RefrigerantR-32
MeteringPiston

CAPFA1818C3: a large 21 in cabinet with a small 1.5-ton capacity

The Goodman CAPFA1818C3 sometimes surprises people: its cabinet is wide, 21 in, but its capacity is still 1.5 tons. Is that a contradiction? Not at all. The width of a coil is set by the width of your furnace; the capacity is set by the load of your house. Here is why this model exists and who it makes sense for.

A wide furnace does not mean a big house

Some furnaces have a generous cabinet even though the home they serve is modest: an older-generation unit, a well-insulated bungalow after renovations, one floor of a duplex. In those cases, a narrow coil would leave gaps on each side of the plenum, and a transition would have to be built.

At 21 in wide, the CAPFA1818C3 fits the air outlet directly. The result: fewer adapter pieces, fewer joints to seal and cleaner work.

What the coil does in your home

It is the part that makes the cold. The refrigerant, arriving from the outdoor unit, evaporates in its tubes and absorbs heat from the air passing through. The water that condenses is collected and drained away. The cooled, drier air goes back into your ducts.

With a heat pump, the direction of the cycle reverses in winter. The same coil then becomes a heat exchanger that gives heat to the air in the house, while the furnace stays ready as backup.

The three siblings with the same capacity

  • CAPFA1818A3: 14 in width, for a narrow furnace;
  • CAPFA1818B3: 17-1/2 in width, for a mid-width furnace;
  • CAPFA1818C3: 21 in width, for a wide furnace. This is the model on this page.

All three are rated at 1.5 tons, use R-32 and have a piston metering device. The choice therefore comes down to measurements.

Two scenarios where the C3 fits

First scenario: you are replacing an ageing central air conditioner in a South Shore house whose furnace, of a good size, is still running well. The wide plenum is already there, with its joints and ducts. The 21 in coil connects to it without improvisation, and the rest of the air distribution stays intact.

Second scenario: you have an electric furnace in a large basement and you want to add a heat pump. The house is well insulated and the calculated load is modest, but the furnace cabinet is wide. Here again, width and capacity do not go hand in hand, and that is normal.

In both cases, we take measurements at the visit, note the furnace's rating plate and check the clear height above the plenum before placing the order. This step avoids unpleasant surprises on installation day.

The role of the insulated cabinet

The cabinet does more than protect the coil. It separates the cold air from the basement's ambient air, which limits condensation on the outside of the sheet metal, and it directs the air through the fins rather than around them. Because it comes with the coil, we do not have to improvise a casing. The two drain connections, primary and secondary, are within easy reach for hookup.

The A shape provides a large exchange surface in a compact volume. Air passes through two sloped faces rather than just one, which gives the refrigerant time to pick up heat without making the cabinet too tall.

And if the house needs more capacity?

The series offers two other models that are 21 in wide: the 2-ton CAPFA2422C3 and the 2.5-ton CAPFA3022C3. They have a taller cabinet than this model, which matters if the clearance above the furnace is limited. We discuss it at the visit.

What the specification sheet says

  • model: CAPFA1818C3, CAPFA line;
  • type: cased coil, A shape;
  • size: 1.5 tons (18,000 BTU/h);
  • refrigerant: R-32;
  • dimensions (W × H × D): 21 × 18 × 21 in;
  • connections: 3/8 in for the liquid line, 3/4 in for the suction line;
  • drain: 3/4 in FNPT, primary and secondary;
  • metering device: piston;
  • installation positions: upflow or downflow;
  • leak detection: R-32 sensor designed to last for the life of the coil;
  • warranty: 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec).

Matching: a coil is never judged alone

Someone may quote you an efficiency figure for a coil. In reality, the SEER2, EER2 and HSPF2 ratings relate to a complete system: one specific coil, one specific outdoor unit, one AHRI number. That number is the one to compare between two quotes.

The CAPFA1818C3 is matched with a Goodman outdoor unit of the same capacity and the same refrigerant. No R-32 match with this coil is listed by ENERGY STAR, so we check AHRI for the outdoor unit selected.

An installation afternoon

The work generally goes in this order, in Montreal as well as in Laval, Longueuil, on the North Shore or on the South Shore:

  • we check the blower, the electrical panel and the furnace's air outlet;
  • the insulated cabinet is set on the plenum and its duct connections are sealed;
  • the outdoor unit is installed on a pad or bracket, and the piping is brazed, nitrogen-tested and then put under vacuum;
  • the drain and the thermostat are connected;
  • the system is commissioned and the airflow is set.

AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, operates under RBQ licence 5645-9605-01.

What to look at before ordering

  • Is the width of the furnace plenum close to 21 in?
  • Does the blower have the capacity to move the system's air?
  • Does the outdoor unit you chose use R-32?
  • Do you only want cooling, or heating as well with a heat pump?

Maintenance: what you can do yourself

A well-installed coil needs little attention, but two simple actions extend its useful life. The first: change or clean the furnace filter on the recommended schedule, because a clogged filter reduces airflow and fouls the fins. The second: keep an eye on the condensate drain. If water appears near the cabinet in the middle of summer, it is a sign that the line needs clearing.

For everything else, coil cleaning, checking the connections and checking the refrigerant charge, it is better to call a technician. R-32 must be handled with suitable equipment.

How long does a project like this take?

The duration depends on the house, but the logic is always the same: one visit to measure, an order, then a day of work to install the coil, the outdoor unit and the connections. If a transition or an electrical upgrade is added, we tell you in advance.

Incentives

Incentives depend on the complete system. We check Hydro-Québec's official list against the installation date, then tell you what applies.

Estimate and financing

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPFA1818C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPFA1818C3
TypeCased evaporator coil
LineCAPFA
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-32
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D21 × 18 × 21 in
Model numberCAPFA1818C3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.