GENERAL AIRSTAGE RLXFZ 2-Head Heat Pump | 24,000 BTU Compressor | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: AOU24RLXFZ-77
24,000BTU/h · 2 heads
−15 °Cheats down to
$705LogisVert, indicative
ENERGY STAR®Optional Wi-FiR-410AUp to 3 heads
Talk to a technician · 514 316-2973
Outdoor unit AOU24RLXFZPossible indoor models ASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLFAHRI 6998279· ENERGY STAR 2409935
In short

The GENERAL AIRSTAGE RLXFZ 2-Head Heat Pump | 24,000 BTU Compressor | Montreal, Laval, Longueuil, South Shore and North Shore multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 14,100 BTU/h at −8 °C, heats down to −15 °C and qualifies for a $705 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 6998279
14,100BTU/h at −8 °C
−15 °Cstill heating
2 → 3heads, on the same unit
$705LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

AOU24RLXFZ

Outdoor unit

One compressor for the whole house. It supplies up to 3 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
24,000BTU
Here3
36,000BTU
234
45,000BTU
2345

GENERAL AIRSTAGE RLXFZ 2-Head Heat Pump | 24,000 BTU Compressor | Montreal, Laval, Longueuil, South Shore and North Shore · 2 zones

14,100 BTU/h
at −8 °C
$705
LogisVert

Up to 3 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 49 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling18.0
Scale 1 – 30
HSPF2 · seasonal heating8.7
Scale 1 – 15
EER2 · cooling in peak heat12.5
Scale 1 – 20
COP at −15 °C1.86
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

14,100 BTU/h÷ 1,000 ×$50=$705

The capacity at −8 °C. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).

Set for this system (AHRI 6998279). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$705 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

35.44 in
AOU24RLXFZDepth 13 in
27.56 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
20 A max. breaker
MCA 17 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 17 A, 20 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

21
40
52
20 dB(A)3040506070
21 Reference head, lowest speed40 Reference head, highest speed52 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)24,000 BTU · 2 tonsSheet
SEER2 (seasonal cooling efficiency)18.0AHRI
EER2 (instant cooling efficiency)12.5AHRI
HSPF2 (seasonal heating efficiency, region IV)8.7AHRI
Dehumidification3.8 pints/hSheet
Heating
Capacity at −8 °C14,100 BTU/hSheet
Capacity at −15 °C11,900 BTU/h · COP 1.86Sheet
Heats down to−15 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones3 Zones (Triple Zone)Sheet
Possible indoor modelsASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLFSheet
Indoor dimensions (W × D × H)33.06 × 8 × 10.5 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)388 CFMSheet
Indoor sound (reference head)21 – 40 dB(A)Sheet
Installation
Outdoor unit (W × D × H)27.56 x 13 x 35.44 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound52 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)17 ASheet
MOP (maximum overcurrent protection)20 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI6998279AHRI
ENERGY STARYes · ID 2409935Sheet
LogisVert grant (indicative)$705Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Description

Everything we have written about this system.

GENERAL AIRSTAGE RLXFZ 2-Zone 24,000 BTU Heat Pump: Two Bedrooms Under the Roof, One Compressor Against the Summer Heat, Installed by AirGreen

What you are looking at here is the Fujitsu AIRSTAGE system built around the AOU24RLXFZ outdoor unit, sold under the GENERAL AIRSTAGE name: a 24,000 BTU compressor, 2 zones and, in this page's configuration, two wall-mounted heads of 7,000 + 7,000 BTU. Only the manufacturer's name has changed: Fujitsu General Limited has been called GENERAL Inc. since January 1, 2026. AHRI certificate 6998279, the ENERGY STAR certification, the published values and the warranty follow the machine, without exception.

The top floor of a condo, as anyone who lives there knows, is the first to heat up in June and the last to cool down in August. The roof soaks up sun all day and releases it into the bedrooms in the evening, at the exact moment you want to sleep. A window air conditioner in each bedroom blocks the view, rattles the glass, and your condo association no doubt has something to say about what hangs out of the windows. A multi-zone heat pump settles the matter cleanly: two wall-mounted heads, a single outdoor unit, one set point per bedroom, and nothing sticking out of the façade anymore.

In Verdun as in LaSalle, many recent condos sit in small flat-roofed buildings, with a balcony or a terrace on the top level. That is often where the outdoor unit finds its place, on a suitable bracket, or on the roof when the building allows it. We give you the technical information the association usually asks for before approving the work: model, planned location, sound level.

GENERAL or Fujitsu AIRSTAGE: the same machine

The story fits in a few dates. In August 2025, Paloma Rheem Holdings, which has owned Rheem since 1988, acquired Fujitsu General. On January 1, 2026, the company became GENERAL Inc. Nothing moved on the technical side: the head office and the R&D centre in Kawasaki, Japan, the factories, the model numbers, the AIRSTAGE products and the warranty program have stayed the same. While the Fujitsu brand gradually fades out, the same AOU24RLXFZ outdoor unit can reach us under either label.

So we show two product pages for a single product, and we say it plainly: pick the one you like, the result installed in your home will be identical. Since February 2026, Rheem Canada has handled sales across the country; our distributor, Groupe Master, does not change.

SpecificationGENERAL AIRSTAGEFujitsu AIRSTAGE
Outdoor unitAOU24RLXFZAOU24RLXFZ
Zones2 (maximum 3)2 (maximum 3)
Heads in this configuration7,000 + 7,000 BTU7,000 + 7,000 BTU
Compatible indoor unitsASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLFASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLF
AHRI certificate69982796998279
Compressor capacity24,000 BTU24,000 BTU
RefrigerantR-410AR-410A
Power supply208/230 V208/230 V
SEER218.018.0
HSPF28.78.7
EER212.512.5
Heating capacity at −8 °C14,100 BTU14,100 BTU
Heating capacity at −15 °C11,900 BTU11,900 BTU
COP at −15 °C1.861.86
Heats down to−15 °C−15 °C
ENERGY STARYesYes
Cold climate (ENERGY STAR)NoNo
ENERGY STAR ID24099352409935
Outdoor unit dimensions (W × D × H, in)27.56 x 13 x 35.4427.56 x 13 x 35.44
Outdoor sound level52.0 dB(A)52.0 dB(A)
Dehumidification3.8 pints/h3.8 pints/h
Wi-FiOptionalOptional
LogisVert grant (Hydro-Québec, list of October 27, 2026)$705$705
Warranty (compressor · parts · labour, years)12 · 12 · 612 · 12 · 6
ManufacturerGENERAL Inc. (Kawasaki, Japan)GENERAL Inc. (Kawasaki, Japan)
Product pageThis pageFujitsu AIRSTAGE RLXFZ 2-zone 24,000 BTU

To see the same system under its former name, visit the Fujitsu AIRSTAGE RLXFZ 2-zone 24,000 BTU page.

Let's start with summer, since it is the whole point of this page. In cooling, the manufacturer publishes a SEER2 of 18.0 and an EER2 of 12.5. SEER2 averages out a full season; EER2 measures what the machine consumes when it is truly hot outside and the compressor does not let up. Under a flat roof in July, that second rating is the one that concerns you most: an EER2 of 12.5 means heat-wave afternoons stay reasonable on the electricity bill.

Top-floor heat is also humid heat. In cooling, the system removes up to 3.8 pints of water per hour from the indoor air. A drier bedroom feels cool at a higher set point, which lets the compressor work less hard for the same quality of sleep.

The two zones each follow their own set point. The main bedroom can go lower for the night while the second bedroom, now an office, stays at a working temperature; when nobody is in it, you put it on standby. The Inverter compressor adjusts its speed to the combined needs of both heads, with no abrupt starts. On the balcony or the roof, the outdoor unit shows a published sound level of 52.0 dB(A), a useful figure when the neighbour's terrace is right next door.

Winter counts too, even on the top floor. According to the values published by the manufacturer, the AOU24RLXFZ delivers 14,100 BTU of heat at −8 °C and 11,900 BTU at −15 °C, with a COP of 1.86 at −15 °C. Translated: on an ordinary January day as on a genuinely cold night, every kilowatt-hour consumed gives you back 1.86 kilowatt-hours of heat, where an electric baseboard gives you back just one. The HSPF2 of 8.7 sums up that performance over the whole heating season. Heating is guaranteed down to −15 °C; this is not a certified cold-climate model, so your baseboards stay in place for the harshest nights.

This page's configuration pairs two 7,000 BTU heads, but the 24,000 BTU compressor gives you some leeway. It accepts up to 3 zones, and you choose your indoor units with us from five compatible models:

  • ASU7RLF1 (7,000 BTU): the guest room or the small office.
  • ASU9RLF1 (9,000 BTU): the main bedroom facing south or west.
  • ASU12RLF1 (12,000 BTU): the open living-kitchen area of recent condos.
  • ASU15RF1 (15,000 BTU): the large open room under a cathedral ceiling.
  • ASU18RLF (18,000 BTU): the very large living room, or the mezzanine open onto the living room.

That possible third zone is worth something in a condo: if you start with the two bedrooms, the open area can be added later to the same compressor, with no second outdoor unit on the balcony. We confirm the combination of capacities with you, so that each room gets the output that suits it.

Here is how the installation goes in a condominium building:

  • The outdoor unit goes on a balcony wall bracket, a terrace base or the roof, depending on what the building allows, with enough air clearance all around.
  • One refrigerant line per head, insulated and protected, follows the most discreet route: along an exterior wall, through a closet or under a painted line cover.
  • Each wall-mounted head is fixed high on a clear wall, aimed to cool the bed without blowing straight onto it.
  • Each head has its own condensate drain; when there is no natural slope, as is common in condos, a small condensate pump takes over.
  • A dedicated electrical circuit, then a full commissioning by a refrigeration technician: R-410A charge check, tests in cooling and in heating.

Maintenance stays light. Each head hides washable indoor filters that come out without tools; a regular rinse in lukewarm water during the summer keeps the airflow intact. A yearly visit from a refrigeration technician covers cleaning the outdoor coil, checking the drain and inspecting the connections. The Wi-Fi module is offered as an option: handy for starting the bedroom cooling before you leave the office.

On the money side, this system carries the ENERGY STAR certification (ID 2409935) and it is on Hydro-Québec's LogisVert list, with a $705 grant according to the October 27, 2026 list. We guide you through the application. The warranty is 12 years on the compressor, 12 years on parts and 6 years on labour.

This system is designed for the owner of a two-bedroom top-floor condo, in Verdun, in LaSalle or elsewhere on the island, who sleeps badly from June to September and wants a permanent, discreet solution the association can accept. It also suits the person who works from home in the second bedroom and refuses to sweat in front of the screen in the afternoon.

Your Condo in Verdun or LaSalle: A Free Quote

Call AirGreen at 514 316-2973 or request a free quote online. We come to see the two bedrooms, the balcony or the roof, then we hand you a clear proposal: outdoor unit location, refrigerant line routing, head capacities. As an AIRSTAGE Elite Plus installer and an HVAC contractor holding an RBQ licence, we work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

The name on the box, GENERAL or Fujitsu, changes nothing about your summer nights. What changes them is a well-placed head in each bedroom and an outdoor unit set where it can breathe, and that is exactly the work we do at your home.

15 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 14,100 BTU/h at −8 °C, 11,900 at −15 °C.

How many heads can I connect?

Up to 3 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$705. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, ID 2409935.

Down to what temperature does it heat?

Down to −15 °C.

Is it noisy?

Indoors, the reference head goes down to 21 dB(A). Outdoors, 52 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $705Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.