GENERAL AIRSTAGE RLXFZ 3-Head Heat Pump | 45,000 BTU Compressor | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: AOU45RLXFZ-999
45,000BTU/h · 3 heads
−15 °Cheats down to
Optional Wi-FiR-410AUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit AOU45RLXFZPossible indoor models ASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLF, ASU24RLFAHRI 8908617
In short

The GENERAL AIRSTAGE RLXFZ 45 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. it delivers 28,200 BTU/h at −8 °C, heats down to −15 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Compared with the 8 multi-zone systems of 45,000 BTU we sell. Figures come from the manufacturer’s data and the AHRI certification.

AHRI 8908617
+Only 55 dB(A) outdoorsRank 1 (tied) of 8. Class median: 55.5 dB(A).
!Good to know: 28,200 BTU/h at −8 °CRank 5 of 8; class median: 29,600 BTU/h.
28,200BTU/h at −8 °C
−15 °Cstill heating
3 → 5heads, on the same unit
02 · Videos

Before the numbers, watch it run.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
24,000BTU
23
36,000BTU
234
45,000BTU
2Here45

GENERAL AIRSTAGE RLXFZ 45 000 · 3 zones

28,200 BTU/h
at −8 °C

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 69 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling20.0
Scale 1 – 30Median: 21
Rank 5 (tied) of 8 in its class.
HSPF2 · seasonal heating9.2
Scale 1 – 15Median: 9.6
Rank 5 (tied) of 8 in its class.
EER2 · cooling in peak heat10.5
Scale 1 – 20Median: 11.3
Rank 5 (tied) of 8 in its class.
COP at −15 °C1.88
Scale 0 – 4Median: 2.01
Rank 5 (tied) of 8 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 8 multi-zone systems of 45,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

38.19 in
AOU45RLXFZDepth 14.56 in
39.31 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
29 A max. breaker
MCA 24 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 24 A, 29 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

21
40
55
20
56
20 dB(A)3040506070
21 Reference head, lowest speed40 Reference head, highest speed20 Class indoor median55 Outdoor unit56 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)45,000 BTUSheet
SEER2 (seasonal cooling efficiency)20.0AHRI
EER2 (instant cooling efficiency)10.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.2AHRI
Dehumidification3.8 pints/hSheet
Heating
Capacity at −8 °C28,200 BTU/hSheet
Capacity at −15 °C31,400 BTU/h · COP 1.88Sheet
Heats down to−15 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLF, ASU24RLFSheet
Indoor dimensions (W × D × H)33.06 × 8 × 10.5 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)388 CFMSheet
Indoor sound (reference head)21 – 40 dB(A)Sheet
Installation
Outdoor unit (W × D × H)39.31 x 14.56 x 38.19 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound55 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)24 ASheet
MOP (maximum overcurrent protection)29 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI8908617AHRI
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

GENERAL AIRSTAGE RLXFZ 3-Zone 45,000 BTU Heat Pump: The Large Suburban Home, Three 9,000 BTU Heads and Room for a Fourth, Installed by AirGreen

This GENERAL AIRSTAGE page describes, down to the last screw, the Fujitsu AIRSTAGE system built around the AOU45RLXFZ outdoor unit: a 45,000 BTU compressor, 3 zones, and a configuration of three wall-mounted heads of 9,000 + 9,000 + 9,000 BTU. The manufacturer, known until now as Fujitsu General Limited, has operated as GENERAL Inc. since January 1, 2026. AHRI certificate 8908617, values published by the manufacturer, a warranty of 12 years on the compressor, 12 years on parts and 6 years on labour: everything is identical.

A large house is not cooled all at once, and it is not heated with a single head. The living spaces are vast, the bedrooms are far from the living room, and needs change over the years: a baby arrives, a teenager moves down to the basement, a parent comes to live with you. This multi-zone system starts with three 9,000 BTU heads and keeps room for a fourth, and even a fifth, on the same compressor. You equip what matters today, and the house follows.

In Terrebonne as in Lachenaie, on the North Shore, the two-storey houses of recent neighbourhoods often have generous open areas, high ceilings and plenty of windows. It is for this kind of house that a 45,000 BTU compressor makes full sense.

GENERAL or Fujitsu AIRSTAGE: the same machine

On January 1, 2026, Fujitsu General Limited took the name GENERAL Inc. It follows the acquisition of the company by Paloma Rheem Holdings, in August 2025; that group has owned Rheem since 1988. For you, the practical consequence is zero: the same factories, the same head office and the same R&D centre in Kawasaki, Japan, the same AIRSTAGE products, the same model numbers, the same warranty program. The Fujitsu brand is leaving the picture in stages, and in the meantime the AOU45RLXFZ outdoor unit carries one name or the other depending on the shipment.

So two pages stay online at AirGreen, with a table showing that every value matches. Rheem Canada has looked after Canadian sales since February 2026, and we keep ordering from Groupe Master, our distributor.

SpecificationGENERAL AIRSTAGEFujitsu AIRSTAGE
Outdoor unitAOU45RLXFZAOU45RLXFZ
Zones3 (maximum 5)3 (maximum 5)
Heads in this configuration9,000 + 9,000 + 9,000 BTU9,000 + 9,000 + 9,000 BTU
Compatible indoor unitsASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLF, ASU24RLFASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RF1, ASU18RLF, ASU24RLF
AHRI certificate89086178908617
Compressor capacity45,000 BTU45,000 BTU
RefrigerantR-410AR-410A
Power supply208/230 V208/230 V
SEER220.020.0
HSPF29.29.2
EER210.510.5
Heating capacity at −8 °C28,200 BTU28,200 BTU
Heating capacity at −15 °C31,400 BTU31,400 BTU
COP at −15 °C1.881.88
Heats down to−15 °C−15 °C
ENERGY STARNoNo
Outdoor unit dimensions (W × D × H, in)39.31 x 14.56 x 38.1939.31 x 14.56 x 38.19
Outdoor sound level55.0 dB(A)55.0 dB(A)
Dehumidification3.8 pints/h3.8 pints/h
Wi-FiOptionalOptional
LogisVert grant (Hydro-Québec, list of October 27, 2026)Not listedNot listed
Warranty (compressor · parts · labour, years)12 · 12 · 612 · 12 · 6
ManufacturerGENERAL Inc. (Kawasaki, Japan)GENERAL Inc. (Kawasaki, Japan)
Product pageThis pageFujitsu AIRSTAGE RLXFZ 3-zone 45,000 BTU

To look at the Fujitsu twin, see the Fujitsu AIRSTAGE RLXFZ 3-zone 45,000 BTU page.

In a large house, cooling weighs heavily on the bill when the equipment is inefficient. The manufacturer publishes a SEER2 of 20.0 for this system, the rating that sums up a full cooling season. The EER2 of 10.5 describes performance in intense heat, the afternoon when the sun hits the big living room windows. In cooling, the system also removes up to 3.8 pints of water per hour, a real help for the basement that smells damp in August.

In winter, capacity in deep cold is what makes the difference. According to the values published by the manufacturer, the AOU45RLXFZ gives 28,200 BTU of heat at −8 °C and 31,400 BTU at −15 °C. The COP of 1.88 at −15 °C represents nearly double the heat a baseboard would draw from the same electricity. Over the whole season, the HSPF2 reaches 9.2: it is the rating to look at to judge what the heat pump will save you on heating. At −8 °C, an ordinary winter afternoon on the North Shore, the machine runs comfortably; at −15 °C, a real January night, it is still heating, with a guarantee to back it up. This is not a certified cold-climate model: the existing heating, baseboards or furnace, stays in place for extreme cold.

Three zones mean three independent set points. The main bedroom upstairs, the living room on the ground floor and the office or the family room each have their own setting, and whatever is unoccupied goes on standby. The Inverter compressor doses its output according to the sum of the demands, without jolts. The published sound level of the outdoor unit is 55.0 dB(A); on a suburban lot, we place it on the side where nobody sleeps with the window open.

This page's configuration, three 9,000 BTU heads, is a balanced starting point for three mid-sized rooms. You still choose your indoor units with us, from six models compatible with the AOU45RLXFZ:

  • ASU7RLF1 (7,000 BTU): the future fourth zone, if it is a child's bedroom.
  • ASU9RLF1 (9,000 BTU): this page's standard head, for a main bedroom or an office.
  • ASU12RLF1 (12,000 BTU): the basement family room.
  • ASU15RF1 (15,000 BTU): a good-sized open-concept living room.
  • ASU18RLF (18,000 BTU): the large room under a cathedral ceiling, kitchen and living room combined.
  • ASU24RLF (24,000 BTU): the largest open area in the house, when a single head has to cover it.

Room for a fourth head, and even a fifth since this compressor accepts up to 5 zones, changes the way you plan. From the first visit, we locate the spot for the next head, so that adding it does not mean redoing the installation. The day the basement is finished or a bedroom changes occupant, a new head connects to the same outdoor unit, and we confirm the total of the capacities with you.

The installation we carry out includes:

  • The outdoor unit on a raised base, above the snow, on the side or at the back of the house, with the space needed for servicing.
  • One refrigerant line per head; for the upstairs heads, the lines run along the façade in a line cover, and those for the ground floor go straight through the exterior wall.
  • Heads placed where they can see the whole room, never in a nook or behind a column.
  • Condensate drainage by gravity to the outside; for a head in the basement, a condensate pump is planned.
  • A dedicated electrical circuit and a full commissioning by a refrigeration technician, zone by zone.

The more heads there are, the more the routine matters. Each head has its washable indoor filters: rinse them regularly during the season, and put a reminder in your calendar if you tend to forget. A yearly visit from our refrigeration technician covers the rest: the outdoor coil, the drains, the connections and the proper operation of each zone. With optional Wi-Fi, you manage the three zones, then the fourth, from your phone.

No grant to expect here: the model is not ENERGY STAR certified and it is not on Hydro-Québec's LogisVert list of October 27, 2026. We would rather tell you right from the start. The appeal of the system lies in its seasonal efficiency, its capacity in deep cold and its warranty.

This is the system for the family living in a large two-storey house who want to equip the three rooms that matter first, without closing the door on what comes next. It also suits anyone planning to finish the basement or welcome a parent, who wants a compressor able to keep up. One outdoor unit, up to five zones: the house can grow without the yard filling up with appliances.

Terrebonne, Lachenaie and the North Shore: Let's Plan Your Three Zones, and the Fourth

For a free quote, phone 514 316-2973 or use our online form. We walk through the house with you, then together we choose the three starting rooms, the location of the outdoor unit and the spot for the future fourth head. As an AIRSTAGE Elite Plus installer and an HVAC contractor licensed by the RBQ, AirGreen travels to Montreal, Laval, Longueuil, the North Shore and the South Shore.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 28,200 BTU/h at −8 °C, 31,400 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 3 heads.

Down to what temperature does it heat?

Down to −15 °C.

Is it noisy?

Indoors, the reference head goes down to 21 dB(A). Outdoors, 55 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 27, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.