2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A

In stock
SKU: DLCMHBH24CAK
24,000BTU/h · 2 heads
$2,160LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 3 heads

Jusqu’à épuisement des stocks

Talk to a technician · 514 316-2973
Outdoor unit DLCMHBH24CAKPossible indoor models DLFSHCH09XAK, DLFSHCH12XAKAHRI 207642990· ENERGY STAR 2545805
In short

The Arcoaire DLCMHB 24 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 18,000 BTU/h at −8 °C and qualifies for a $2,160 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 207642990
18,000BTU/h at −8 °C
2 → 3heads, on the same unit
$2,160LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DLCMHBH24CAK

Outdoor unit

One compressor for the whole house. It supplies up to 3 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
24,000BTU
Here3
30,000BTU
234
36,000BTU
234
48,000BTU
2345

Arcoaire DLCMHB 24 000 · 2 zones

18,000 BTU/h
at −8 °C
$2,160
LogisVert

Up to 3 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 70 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling22.3
Scale 1 – 30
HSPF2 · seasonal heating9.6
Scale 1 – 15
EER2 · cooling in peak heat12.5
Scale 1 – 20
COP at −15 °C1.83
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

18,000 BTU/h÷ 1,000 ×$120=$2,160

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 207642990). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$2,160 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

$2,160LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)24,000 BTU · 2 tonsSheet
SEER2 (seasonal cooling efficiency)22.3AHRI
EER2 (instant cooling efficiency)12.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.6AHRI
Heating
Capacity at −8 °C18,000 BTU/hSheet
Capacity at −15 °C17,000 BTU/h · COP 1.83Sheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones3 Zones (Triple Zone)Sheet
Possible indoor modelsDLFSHCH09XAK, DLFSHCH12XAKSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI207642990AHRI
ENERGY STARYes · cold climate · ID 2545805Sheet
LogisVert grant (indicative)$2,160Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Description

Everything we have written about this system.

The living room and the bedroom, each at its own temperature, with a single condenser outside

In many homes, the living room and the main bedroom never ask for the same thing at the same time. The living room gets the afternoon sun and fills up in the evening; the bedroom wants cool air at night and a little warmth when you wake up. The 2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A handles that difference with two independent wall heads connected to a single DLCMHBH24CAK condenser. Each room keeps its own set point, remote and schedule, and the outdoor unit adjusts its speed to the heads that are calling.

This 2-ton condenser serves 2 zones here and accepts up to 3 at most. The wall heads intended for it are the DLFSHCH09XAK and the DLFSHCH12XAK. Its certified ratings are 22.3 SEER2, 12.5 EER2 and 9.6 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2545805, and our product sheet shows an indicative LogisVert amount of $2,160.

The homes this size is designed for

We recommend this configuration when two rooms carry most of the home's comfort: a living room open to the kitchen and the main bedroom, a ground floor and a bedroom floor, or a home office used all day while the rest of the home stays at a low temperature. In a well-insulated 4 ½ or 5 ½, two well-placed heads cover most of the year. In an older house, with tired windows or poorly insulated walls, the same configuration still makes sense, but we size it with the existing electric baseboards kept as backup for the coldest nights.

The size is not chosen by eye. Floor area matters, but window orientation, ceiling height, envelope airtightness and the number of occupants weigh just as much. That is why our quote comes after a visit, never before.

Why two heads rather than one large one

A single wall-mounted heat pump, even a generous one, heats the room it is installed in well and the rooms behind a door much less. The bedroom, closed at night, stays cold in January and warm in July, while the living room is overheated. With one head per room, air is delivered where you live, and each space is set without compromise: the living room a little warmer in the evening, the bedroom cooler for sleeping.

The choice of heads follows the same logic. The DLFSHCH09XAK, the smaller of the two, suits a bedroom or an office. The DLFSHCH12XAK takes a larger or more exposed room, such as a medium-sized living room. We confirm which head goes where during the visit, after the needs assessment.

What happens inside the inverter condenser

The condenser's inverter compressor does not run on an on-off cycle. It speeds up when both heads call at the same time, then slows down when only one room needs heat or the set point is reached. The condenser meters the R-410A refrigerant sent to each head according to its demand, which keeps temperatures steady and avoids the repeated starts that wear out equipment.

Two operating rules are worth knowing. First, the heads on the same condenser work in the same mode: all heating or all cooling. In practice this almost never gets in the way, since both rooms are living through the same season. Second, when every head calls at full demand, they share the condenser's capacity. That is why we size room by room rather than dividing the capacity into equal shares.

Winter in Montreal: what the certified figures say

The certificate lists 18,000 BTU/h at -8 °C (17 °F) and 17,000 BTU/h at -15 °C (5 °F), with a COP of 1.83 at the -15 °C point. The two points are measured separately; we report each one as published.

At -8 °C, the condenser still delivers 75% of its 24,000 BTU nominal size, which covers the vast majority of winter days in Greater Montreal. A COP of 1.83 means that at -15 °C, each kilowatt-hour consumed returns 1.83 kilowatt-hours of heat, where a baseboard returns one. During deep cold snaps, the two heads share the available capacity; that is when the existing backup takes over in a less well-insulated house.

You should also expect defrost cycles. In cold, humid weather, the outdoor coil frosts over and the condenser clears it for a few minutes. The heads then stop blowing warm air and a cloud of white vapour may rise from the outdoor unit. This is normal.

Summer cooling and dehumidification

In cooling, the system is designed around a nominal size of 24,000 BTU/h shared between the two rooms. The variable-speed compressor runs for long periods at low speed rather than cooling hard and shutting off; the air therefore passes more slowly over the cold coil, which removes more moisture. You notice it most in a bedroom: less clammy air and more comfortable sleep, without the dry chill of an oversized window air conditioner.

Each head also offers a dehumidification mode for muggy days when the outdoor temperature does not justify full cooling.

SEER2, EER2, HSPF2: what these ratings mean for you

  • 22.3 SEER2: seasonal cooling efficiency, measured over a typical summer. The higher the number, the less summer costs in electricity.
  • 12.5 EER2: cooling efficiency in hot weather, at full load. It matters during heat waves.
  • 9.6 HSPF2: seasonal heating efficiency. This is the rating that weighs most on a Quebec household's bill.
  • COP: the ratio between heat delivered and electricity consumed at a given temperature.

These figures come from certificate AHRI 207642990, as published by ENERGY STAR.

Indicative LogisVert amount: $2,160

Our product sheet shows an indicative LogisVert amount of $2,160 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing, check that the installed combination matches the one on the list, then prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

From the visit to commissioning

Our installation, step by step

  1. Visit and needs assessment: we measure each room, note the windows and insulation, then confirm which head goes where.
  2. Condenser location: above the snow line, on a wall bracket or a stand, sheltered from snow sliding off the roof and away from bedroom windows.
  3. Refrigerant lines: each head gets its own line set back to the condenser, insulated and protected by a line cover outdoors.
  4. Drain: each head has its own condensate drain, sloped so the water flows out without backing up.
  5. Electrical: a dedicated circuit for the condenser, checked at the panel during the visit.
  6. Commissioning: vacuum, leak test, check of each zone's operation, then setup of the remotes with you.

A third connection available for later

The DLCMHBH24CAK condenser accepts up to 3 zones. If a basement gets finished or an office is added in a few years, a third head can sometimes be connected to it. Before any addition, we check that the condenser's capacity is enough for all three rooms and that the combination follows the manufacturer's rules. If it does not, we tell you plainly and propose another solution.

Maintenance

Rinse the head filters every two weeks in season; they come out by hand, without tools. Keep the outdoor unit clear of snow, ice and leaves, and do not cover it in winter: it heats in January too. Plan one HVAC maintenance visit per year to clean the coils, drain and fans and to check the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

Warranty

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.

The serial numbers of the condenser and the heads appear on your invoice, which simplifies any warranty claim.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A. We assess both rooms and confirm the right size and your grant eligibility before signing.

Available while supplies last.

15 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 18,000 BTU/h at −8 °C, 17,000 at −15 °C.

How many heads can I connect?

Up to 3 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$2,160. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 2545805.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $2,160Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.