The Arcoaire DLCMHB 48 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 39,000 BTU/h at −8 °C and qualifies for a $4,680 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 5 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 93 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
Everything we have written about this system.
Four zones on two floors: the daytime rooms, the night-time rooms and a single condenser
A large house is never fully occupied at the same time. During the day, life happens on the ground floor; in the evening, everyone goes up to the bedrooms. The 4-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A follows that movement with four independent wall heads, spread over both floors and connected to a single DLCMHBH48EAK condenser that directs its capacity to the occupied rooms.
This 4-ton condenser serves 4 zones here and accepts up to 5 at most. The wall heads intended for it are the DLFSHCH09XAK, the DLFSHCH12XAK and the DLFSHCH24XAK. Its certified ratings are 21.2 SEER2, 11.0 EER2 and 10.0 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2410134, and our product sheet shows an indicative LogisVert amount of $4,680.
Daytime zones, night-time zones
In a two-storey house, two zones are used during the day: the large living space and the kitchen or dining room. Two others are used at night: the main bedroom and a second bedroom, or a bedroom and an office. With a head in each one, you set the daytime rooms for the day and the night-time rooms for sleep, without heating or cooling an empty bedroom at noon.
This requires no complicated programming. Each remote keeps its own set point, and the condenser distributes its capacity according to the heads that are actually calling. During the day, the daytime rooms benefit; in the evening, demand moves upstairs.
For which homes
This size targets large houses without ducts: a two-storey with an open living space on the ground floor and several bedrooms upstairs, a bungalow with a finished basement, or an extended house whose parts have neither the same exposure nor the same insulation. In a well-insulated house, it replaces most of the electric baseboard heating and cools both floors in summer.
In an older house, we estimate the share the four heads can take on and the share left to the backup. The figure that matters is not the floor area, but the load of each room.
Choosing the four heads
The DLFSHCH24XAK, the largest of the intended heads, goes in the open living space. The DLFSHCH12XAK suits the kitchen, the dining room or the main bedroom, and the DLFSHCH09XAK the smaller bedrooms and the office. A head that is too large in a small bedroom reaches its set point too quickly and removes less moisture; a head that is too small in the living room strains without ever catching up. The on-site assessment avoids both mistakes.
The four heads share the condenser's capacity. When they all call at full demand, it is split between them. With 4 zones out of a maximum of 5, one connection remains free for a room added later, after checking the remaining capacity.
The cold, backed by the certificate's figures
The certificate lists 39,000 BTU/h at -8 °C (17 °F), with a COP of 2.50, and 45,000 BTU/h at -15 °C (5 °F), with a COP of 2.00. The maximum published capacity is 45,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
At -15 °C, the four heads therefore have 94% of the condenser's nominal size available, and each kilowatt-hour consumed returns two kilowatt-hours of heat, where a baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.
The certificate does not publish a colder point. Keep the existing baseboards as backup, set slightly below the heads' set point: they serve during extreme cold and during defrost cycles, those few minutes when the condenser melts the frost off its coil and a cloud of vapour escapes from it.
These figures come from certificate AHRI 207642999, published by NEEP.
How the compressor follows the house
The condenser's inverter compressor does not run on an on-off cycle. It speeds up when several heads call, slows down when the set points are reached, and meters the R-410A refrigerant sent to each head according to its demand. When the family moves from the daytime rooms to the bedrooms, the condenser follows, smoothly.
As on any multi-zone system of this type, the four heads work in the same mode: all heating or all cooling. Shutting off an unoccupied zone, a guest room for example, leaves the other three running normally.
Summer upstairs and on the ground floor
In cooling, the system is built around a nominal size of 48,000 BTU/h for the four zones. In the afternoon, the living space and kitchen ask the most; in the evening, it is the upstairs bedrooms, heated by the roof all day. Extended low-speed operation removes moisture from the air, and each head offers a dehumidification mode for muggy days.
The ratings, one by one
The HSPF2 of 10.0 measures heating efficiency over the whole cold season; for a large house heated largely by heat pump, it is the rating that weighs most. The SEER2 of 21.2 measures cooling efficiency over a whole summer. The EER2 of 11.0 measures cooling at full load, in hot weather. The COP expresses efficiency at a specific temperature: 2.50 at -8 °C and 2.00 at -15 °C.
Indicative LogisVert amount: $4,680
Our product sheet shows an indicative LogisVert amount of $4,680 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
An installation planned over two floors
Lines, drains and electrical
Four heads means four refrigerant line sets, all running back to the same condenser. We place it where the routes are shortest, above the snow line, on a stand or a sturdy bracket, sheltered from snow sliding off the roof. The lines for the upstairs heads run up a painted line cover along the facade, or go indoors when a closet or the attic allows it. We show you each route before drilling.
Each head has its own condensate drain, sloped toward the outside; a condensate pump is only planned where gravity is not enough. The 4-ton condenser is connected to a dedicated circuit, and we check the panel's space and capacity during the visit. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the four remotes with you.
Maintenance
Rinse the filters of all four heads every two weeks in season, preferably on the same day. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. On a system where every zone depends on the same condenser, this visit reduces the risk of a shutdown in the middle of winter. Our cleaning service takes over when you prefer to hand off the annual visit.
Warranty
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 4-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A. We assess both floors room by room and confirm the right size and your grant eligibility before signing.
Available while supplies last.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 39,000 BTU/h at −8 °C, 45,000 at −15 °C.
How many heads can I connect?
Up to 5 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$4,680. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 2410134.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.