2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A

In stock
SKU: DLCMHBH48EAK
48,000BTU/h · 2 heads
$4,680LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 5 heads

Jusqu’à épuisement des stocks

Talk to a technician · 514 316-2973
Outdoor unit DLCMHBH48EAKPossible indoor models DLFSHCH09XAK, DLFSHCH12XAK, DLFSHCH24XAKAHRI 207642999· ENERGY STAR 2410134
In short

The Arcoaire DLCMHB 48 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 39,000 BTU/h at −8 °C and qualifies for a $4,680 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 207642999
39,000BTU/h at −8 °C
2 → 5heads, on the same unit
2.5COP at −8 °C
$4,680LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DLCMHBH48EAK

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
24,000BTU
23
30,000BTU
234
36,000BTU
234
48,000BTU
Here345

Arcoaire DLCMHB 48 000 · 2 zones

39,000 BTU/h
at −8 °C
$4,680
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 93 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.2
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat11.0
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

39,000 BTU/h÷ 1,000 ×$120=$4,680

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 207642999). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,680 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

13,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$4,680LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTU · 4 tonsSheet
SEER2 (seasonal cooling efficiency)21.2AHRI
EER2 (instant cooling efficiency)11.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C39,000 BTU/h · COP 2.5Sheet
Capacity at −15 °C45,000 BTU/h · COP 2.0Sheet
Capacity at -15 °C (max.)45,000 BTU/h · COP 2.0Sheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsDLFSHCH09XAK, DLFSHCH12XAK, DLFSHCH24XAKSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI207642999AHRI
ENERGY STARYes · cold climate · ID 2410134Sheet
LogisVert grant (indicative)$4,680Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Description

Everything we have written about this system.

Two very large living areas, a single 4-ton condenser to heat them

Some houses come down to two large volumes: a ground floor open from end to end and a finished basement almost as big. For these spaces, a small wall head is not enough, and several separate units clutter the walls. The 2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A answers with two large wall heads connected to a single DLCMHBH48EAK condenser.

This 4-ton condenser serves 2 zones here and accepts up to 5 at most. The wall heads intended for it are the DLFSHCH09XAK, the DLFSHCH12XAK and the DLFSHCH24XAK. Its certified ratings are 21.2 SEER2, 11.0 EER2 and 10.0 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2410134, and our product sheet shows an indicative LogisVert amount of $4,680.

When two zones are enough for a large house

This size targets homes where life is concentrated in two large open rooms: a single-storey house whose living room, kitchen and dining room form one space, and a basement used as a family room, playroom or workshop. It also suits a large extended house, whose new wing and original part are heated separately.

It also has its limits, and we prefer to say so right away. A wall head heats the room it is in; it does not push air behind closed doors. If your house has several closed bedrooms, a configuration with three, four or five zones on the same condenser will serve them better. The on-site assessment and the site visit settle the question.

The DLFSHCH24XAK, the head for large volumes

For a large open space, the DLFSHCH24XAK, the largest of the intended heads, is the usual choice. It is mounted high on the longest wall, so it blows across the full depth of the room. Under a cathedral ceiling, we account for the heat that rises and the air that has to come back down to the occupied zone. The second zone gets the head that matches its actual load: another DLFSHCH24XAK if it is just as large, the DLFSHCH12XAK or the DLFSHCH09XAK if it is more modest.

The two heads share the condenser's capacity. When both call at full demand, it is split between them; when only one zone is occupied, it gets all the available capacity.

Electrical capacity, to be checked first

A 4-ton condenser requires a larger dedicated circuit than a small wall-mounted heat pump. Before proposing this system, we open the electrical panel during the visit: available space, capacity of the electrical service, loads already connected such as a range, a dryer or a water heater. In a house whose panel is already heavily loaded, an upgrade may be needed; we point it out during the visit, along with the rest of our findings. The electrical work is part of the written quote, just like the condenser and the heads.

Winter according to the certificate

The certificate lists 39,000 BTU/h at -8 °C (17 °F), with a COP of 2.50, and 45,000 BTU/h at -15 °C (5 °F), with a COP of 2.00. The maximum published capacity is 45,000 BTU/h at -15 °C, at the same COP. The two points are measured separately; we report each one as published.

At -15 °C, the condenser therefore delivers 94% of its 48,000 BTU nominal size. A COP of 2.00 means that at that temperature, each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.

The certificate does not publish a colder point. We therefore recommend keeping the electric baseboards or other existing heating as backup, set slightly below the heads' set point. They stay off for most of the winter and only serve during extreme cold and defrost cycles, those few minutes when the condenser melts the frost off its coil and lets out a cloud of vapour.

These figures come from certificate AHRI 207642999, published by NEEP.

Inverter and cooling for large volumes

The condenser's inverter compressor varies its speed according to demand and meters the R-410A refrigerant sent to each head. In a large room, it runs for long periods at moderate speed, which keeps the air moving continuously and prevents heat from getting trapped under the ceiling. The two heads always work in the same mode, heating or cooling.

In cooling, the system is built around a nominal size of 48,000 BTU/h for the two zones. The large windows of an open area and the kitchen make it the most heavily loaded zone in summer; in the basement, humidity dominates. Extended low-speed operation and each head's dehumidification mode remove that moisture without needlessly cooling the room.

The 21.2 SEER2, 11.0 EER2 and 10.0 HSPF2 ratings

HSPF2 measures heating efficiency over the whole cold season. At 10.0, it is the rating to remember for a house heated largely by heat pump, since heating accounts for most of the bill in Quebec. The SEER2 of 21.2 measures cooling efficiency over a whole summer, and the EER2 of 11.0 measures cooling at full load, in hot weather. Finally, the COP expresses efficiency at a specific temperature: 2.50 at -8 °C and 2.00 at -15 °C for this system.

Indicative LogisVert amount: $4,680

Our product sheet shows an indicative LogisVert amount of $4,680 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Installation and maintenance

Our installation

The visit starts with the two spaces: dimensions, windows, insulation, ceiling height. The on-site assessment then confirms the size and the choice of heads. A condenser of this size usually sits on a stand or a sturdy bracket, above the snow line and away from snow sliding off the roof. Each head gets its own refrigerant line set, protected by a line cover outdoors, and its own sloped condensate drain. In the basement, a condensate pump becomes necessary when gravity is not enough.

Commissioning includes the vacuum, the leak test, a check of each zone and setup of the remotes with you. With 2 zones out of a maximum of 5, the condenser keeps free connections for rooms added later, after checking the remaining capacity.

Maintenance

Rinse the filters of both heads every two weeks in season. Keep the condenser clear of snow, ice and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

Warranty

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A. We assess your two large spaces and your electrical panel and confirm the right size and your grant eligibility before signing.

Available while supplies last.

15 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 39,000 BTU/h at −8 °C, 45,000 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$4,680. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 2410134.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,680Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.