3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A

In stock
SKU: DLCMHBH30DAK
30,000BTU/h · 3 heads
$1,350LogisVert, indicative
ENERGY STAR®Optional Wi-FiR-410AUp to 4 heads

Jusqu’à épuisement des stocks

Talk to a technician · 514 316-2973
Outdoor unit DLCMHBH30DAKPossible indoor models DLFSHCH09XAK, DLFSHCH12XAK, DLFSHCH18XAKAHRI 207642993· ENERGY STAR 2545779
In short

The Arcoaire DLCMHB 30 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. it delivers 27,000 BTU/h at −8 °C and qualifies for a $1,350 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 207642993
27,000BTU/h at −8 °C
3 → 4heads, on the same unit
$1,350LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DLCMHBH30DAK

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
24,000BTU
23
30,000BTU
2Here4
36,000BTU
234
48,000BTU
2345

Arcoaire DLCMHB 30 000 · 3 zones

27,000 BTU/h
at −8 °C
$1,350
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 76 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling22.4
Scale 1 – 30
HSPF2 · seasonal heating9.5
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C1.65
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

27,000 BTU/h÷ 1,000 ×$50=$1,350

The capacity at −8 °C. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).

Set for this system (AHRI 207642993). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$1,350 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

$1,350LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)30,000 BTU · 2,5 tonsSheet
SEER2 (seasonal cooling efficiency)22.4AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)9.5AHRI
Heating
Capacity at −8 °C27,000 BTU/hSheet
Capacity at −15 °C23,000 BTU/h · COP 1.65Sheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsDLFSHCH09XAK, DLFSHCH12XAK, DLFSHCH18XAKSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI207642993AHRI
ENERGY STARYes · ID 2545779Sheet
LogisVert grant (indicative)$1,350Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Description

Everything we have written about this system.

Three zones to put the window air conditioners away and take the load off the baseboards

Many homes in Greater Montreal live with the same compromise: an air conditioner in the living room window, another in a bedroom, and electric baseboards everywhere for winter. The 3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A replaces that patchwork with three wall heads that heat and cool, connected to a single DLCMHBH30DAK condenser.

This 2.5-ton condenser serves 3 zones here and accepts up to 4 at most. The wall heads intended for it are the DLFSHCH09XAK, the DLFSHCH12XAK and the DLFSHCH18XAK. Its certified ratings are 22.4 SEER2, 12.0 EER2 and 9.5 HSPF2. The system is ENERGY STAR certified under ENERGY STAR ID 2545779 and our product sheet shows an indicative LogisVert amount of $1,350.

The typical semi-detached: a ground floor and two bedrooms

The most common configuration for this system is a semi-detached or a mid-sized two-storey house: one head for the living room and kitchen on the ground floor, one for the main bedroom, one for the second bedroom or the office. It also suits a bungalow where the living room, the bedroom and a basement room need to be handled separately.

The right result depends on the house. A well-insulated house with recent windows lets the three heads do most of the work. In an older house, we estimate what the heat pump can cover and what is left to the baseboards, then we write it into the quote.

Putting the window air conditioners away for good

A wall head frees the window, all year round. No more unit to put in every spring and take out every fall, no more poorly sealed opening all summer, no more blocked window that will not lock. The condenser is outside, and only a discreet flow of air remains in the room.

You also feel the difference in comfort. A window air conditioner cools hard, stops, then starts again; the air ends up cold and clammy at the same time. The condenser's inverter compressor runs for long periods at low speed, removes moisture from the air and keeps a steady temperature. For cooling, the system is built around a nominal size of 30,000 BTU/h, distributed among the three rooms according to their demand.

Three heads, three possible sizes

The three heads do not have to be identical. The DLFSHCH18XAK, the largest, generally goes in the living room. The DLFSHCH12XAK suits a main bedroom or a south-facing room, and the DLFSHCH09XAK a small bedroom or an office. The exact combination is decided after the on-site assessment, room by room.

The heads share the condenser's capacity. When they all call together, it is split between them; when only one room is occupied, it gets all the available capacity. With 3 zones out of a maximum of 4, one connection remains free: a fourth room can be added later if the remaining capacity allows it, which we check before any addition.

Spring and fall: the season when the heat pump pays off most

People think mostly about the deep cold, but a good part of a Quebec home's heating happens in cool weather: in October, November, March and April. At those temperatures, the heat pump does all the work, the baseboards stay off and efficiency is at its best. That is where the HSPF2 rating of 9.5, which measures heating efficiency over the whole season, takes on its meaning.

One piece of practical advice follows from this. With a heat pump, it is better to keep a steady set point in each zone than to lower it sharply at night and raise it again in the morning. The inverter compressor works more efficiently at a moderate, constant speed than when catching up, and the baseboards do not have to step in to close the gap. If a room is unoccupied for several days, simply lower its set point or shut off its zone.

The January cold, backed by figures

The certificate lists 27,000 BTU/h at -8 °C (17 °F) and 23,000 BTU/h at -15 °C (5 °F), with a COP of 1.65 at the -15 °C point. The two points are measured separately; we report each one as published.

At -15 °C, the condenser delivers 77% of its nominal size, shared among the three heads. A COP of 1.65 means that each kilowatt-hour consumed still returns 1.65 kilowatt-hours of heat, where a baseboard returns one. This system is ENERGY STAR certified, but it does not carry the cold-climate designation: we therefore recommend it with the existing baseboards kept as backup for the coldest nights.

In cold, humid weather, the condenser runs defrost cycles of a few minutes, during which the heads stop blowing warm air. The white vapour that then rises from the outdoor unit is normal.

These figures come from certificate AHRI 207642993, as published by ENERGY STAR.

What the condenser does differently

A multi-zone condenser is not three units packed into one box. It meters the R-410A refrigerant sent to each head according to its demand, slows down when the set points are reached and speeds up when several rooms call. Shutting off an unoccupied zone leaves the others running normally. All the heads work in the same mode, heating or cooling; for a home that lives through the same season from one room to the next, this has no consequence.

The ratings, in plain terms

The SEER2 of 22.4 measures cooling efficiency over a whole summer. The EER2 of 12.0 measures cooling at full load, during a heat wave. The HSPF2 of 9.5 measures heating over the entire cold season. Finally, the COP expresses efficiency at a specific temperature: it is the ratio between heat delivered and electricity consumed.

Indicative LogisVert amount: $1,350

Our product sheet shows an indicative LogisVert amount of $1,350 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Three zones installed without cluttering the facade

From the on-site assessment to commissioning

  1. Visit: we measure the three rooms and note the windows, the insulation and the electrical panel.
  2. On-site assessment: it confirms the condenser size and the right head for each room.
  3. Condenser: set above the snow line, on a wall bracket or a stand, sheltered from snow sliding off the roof.
  4. Refrigerant lines: one set per head, grouped in a line cover on the facade for a clean route.
  5. Drains: one sloped condensate drain per head.
  6. Electrical: a dedicated circuit for the condenser, checked at the panel.
  7. Commissioning: vacuum, leak test, check of each zone and setup of the remotes with you.

Maintenance

Rinse the filters of all three heads every two weeks in season. Keep the condenser clear of snow, ice and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

Warranty

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A. We assess your three rooms and confirm the right size and your grant eligibility before signing.

Available while supplies last.

15 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 27,000 BTU/h at −8 °C, 23,000 at −15 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$1,350. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, ID 2545779.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $1,350Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.