GENERAL AIRSTAGE Aquila R32 3-Zone Heat Pump | 36,000 BTU | Montreal, Laval, South Shore, North Shore
The GENERAL AIRSTAGE Aquila R32 36 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. it delivers 23,600 BTU/h at −8 °C, heats down to −15 °C and qualifies for a $1,180 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
3 rooms, one outdoor unit.
Compared with the 141 multi-zone systems of 36,000 BTU we sell. Every number on this page carries its source.
Before the numbers, watch it run.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 66 % of its rated capacity.
Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.
It slows down, it speeds up: the certified modulation range
Light bar: from minimum to maximum capacity. Dark mark: the rated value.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.
A grant you can calculate, not guess.
The capacity at −8 °C comes from Hydro-Québec’s list of October 27, 2026. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).
Where it ranks among same-size multi-zone systems.
Compared with the 141 multi-zone systems of 36,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.
Against three other brands in its class.
Same rated size, other manufacturers. Pick the opponent.
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
GENERAL AIRSTAGE Aquila 3-Zone Heat Pump, 36,000 BTU: two bedrooms and a 12,000 BTU living area in the semi-detached house, on a single compressor installed by AirGreen
The semi-detached house in Boucherville or Sainte-Julie has its own rules: a party wall on one side, a single free side wall on the other, and a backyard you share, at least by sight, with the neighbour. To heat and cool it without ducts, you need a solution that fits in little outdoor space and still covers the rooms that count: the living area on the main floor and the two bedrooms upstairs.
The GENERAL AIRSTAGE Aquila 3-zone 36,000 BTU does exactly that, with a single outdoor unit AOUH36KWAS4 and three wall-mounted heads in a 7,000 + 7,000 + 12,000 BTU configuration. It is the machine sold under the name Fujitsu AIRSTAGE Aquila 3-zone with this same compressor. The manufacturer, renamed GENERAL Inc. on January 1, 2026, has not changed; neither have the AHRI certificate 215447689, the certified values or the warranty (compressor 12 years, parts 12 years, labour 6 years).
The logic of the configuration follows that of the house: the 12,000 BTU head for the living area, which often opens onto the kitchen and the dining room, and two 7,000 BTU heads for the bedrooms. Three independent setpoints, and a fourth zone possible later, since this compressor accepts four.
GENERAL or Fujitsu AIRSTAGE: the same machine
Your neighbour, on the other side of the party wall, may have a Fujitsu on their back wall. If yours carries the GENERAL name, it will be the same machine. The Paloma Rheem Holdings group, which Rheem has belonged to since 1988, became the owner of Fujitsu General in August 2025; Fujitsu General Limited then adopted the name GENERAL Inc. as of January 1, 2026. The AIRSTAGE products kept their model numbers and their warranty program; they come out of the same factories and report to the same head office and the same R&D centre, in Kawasaki, Japan. The GENERAL name, for its part, has existed since 1946.
In Canada, Rheem Canada has handled sales since February 2026, and AirGreen keeps buying from Groupe Master. The Fujitsu brand is being phased out gradually and, until then, the same system is sold under both names: that is why we keep both pages and why the table below lines up two identical columns.
| Specification | GENERAL AIRSTAGE | Fujitsu AIRSTAGE |
|---|---|---|
| Outdoor unit | AOUH36KWAS4 | AOUH36KWAS4 |
| Zones | 3 (maximum 4) | 3 (maximum 4) |
| Heads in this configuration | 7,000 + 7,000 + 12,000 BTU | 7,000 + 7,000 + 12,000 BTU |
| Compatible indoor units | ASUH07KPAS, ASUH09KPAS, ASUH12KPAS, ASUH15KPAS, ASUH18KPAS, ASUH24KPAS | ASUH07KPAS, ASUH09KPAS, ASUH12KPAS, ASUH15KPAS, ASUH18KPAS, ASUH24KPAS |
| AHRI certificate | 215447689 | 215447689 |
| Compressor capacity | 36,000 BTU | 36,000 BTU |
| Refrigerant | R-32 | R-32 |
| Power supply | 208/230 V | 208/230 V |
| SEER2 | 22.0 | 22.0 |
| HSPF2 | 10.0 | 10.0 |
| EER2 | 12 | 12 |
| Heating capacity at −8 °C | 23,600 BTU | 23,600 BTU |
| COP at −8 °C | 3.10 | 3.10 |
| Heating capacity at −15 °C | 24,000 BTU | 24,000 BTU |
| COP at −15 °C | 2.20 | 2.20 |
| Heats down to | −15 °C | −15 °C |
| ENERGY STAR | Yes | Yes |
| Cold climate (ENERGY STAR) | No | No |
| ENERGY STAR ID | 3627394 | 3627394 |
| Outdoor unit dimensions (W × D × H, in) | 32.31 x 12.38 x 34.81 | 32.31 x 12.38 x 34.81 |
| Outdoor sound level | 56.0 dB(A) | 56.0 dB(A) |
| Wi-Fi | Optional | Optional |
| LogisVert grant (Hydro-Québec, list of October 27, 2026) | $1,180 | $1,180 |
| Warranty (compressor · parts · labour, years) | 12 · 12 · 6 | 12 · 12 · 6 |
| Manufacturer | GENERAL Inc. (Kawasaki, Japan) | GENERAL Inc. (Kawasaki, Japan) |
| Product page | This page | Fujitsu AIRSTAGE Aquila 3-zone 36,000 BTU |
You can also look at the Fujitsu AIRSTAGE Aquila 3-zone 36,000 BTU page, which describes the same AOUH36KWAS4 in the same configuration.
In winter, the living area of a semi-detached house loses its heat through the patio door and the large windows, while the bedrooms benefit from the party wall. The values certified by NEEP (ashp.neep.org), AHRI certificate 215447689, show what the system can deliver: 23,600 BTU/h at −8 °C with a COP of 3.1, and 29,000 BTU/h at peak at that temperature; 24,000 BTU/h at −15 °C with a COP of 2.2. Heating is guaranteed down to −15 °C. Below that threshold, the existing electric heating tops up on its own, according to each room's thermostat.
Even at −15 °C, its COP of 2.2 means it produces more than double the heat of a baseboard for the same electricity. The HSPF2 of 10.0, for its part, sums up the whole winter in a single figure: the higher it is, the less the season costs. When summer comes, the SEER2 of 22.0 and the EER2 of 12.0 play the same role for cooling. The ENERGY STAR Most Efficient designation places it among the most efficient of the year; the cold-climate designation, on the other hand, is not granted to it, which changes nothing about its certified capacity at −15 °C.
The Inverter compressor modulates its speed according to demand and goes down to 11,000 BTU/h, its lowest speed certified by NEEP. In the shoulder seasons, when only the living area asks for a little heat, it slows down rather than stopping and starting over and over.
In a semi-detached house, outdoor noise quickly becomes a neighbourhood matter. The outdoor unit is measured at 56.0 dB(A); we place it on the free side wall or at the back, away from the neighbour's patio door and from your bedroom windows, and never against the party wall, which would carry the vibrations.
The refrigerant is R-32; its global warming potential of 675 compares with 2,088 for R-410A, according to ENERGY STAR.
The 7,000 + 7,000 + 12,000 BTU configuration follows the typical layout of a semi-detached house, but every house has its particulars. The final choice of heads is made with us, from the list of indoor units this compressor accepts:
- ASUH07KPAS, 7,000 BTU, the secondary bedroom;
- ASUH09KPAS, 9,000 BTU, the master bedroom;
- ASUH12KPAS, 12,000 BTU, the living area open to the kitchen;
- ASUH15KPAS, 15,000 BTU, a larger or heavily glazed living area;
- ASUH18KPAS, 18,000 BTU, a fully open main floor;
- ASUH24KPAS, 24,000 BTU, the largest of the compatible heads.
The compressor accepts up to four zones. The finished basement or an office can become the fourth, and we will confirm the complete combination during the visit.
The semi-detached house forces us to group the runs. The two bedroom refrigerant lines come down together in the same line cover, on the free side wall or at the back, and the living-area line joins them on the main floor: one line per head, all going to the same outdoor unit. The unit rests on a stand raised above the snow, or on brackets fixed to a wall that is not the party wall. The drains flow by gravity to the outside for heads mounted on an exterior wall, and through a condensate pump for a head on an interior wall. A dedicated electrical circuit runs from the panel.
Routine maintenance comes down to the indoor filters of the three heads, washable, which come out without tools. The living-area one works the hardest, especially with the open kitchen: rinse it more often than the other two. A refrigeration technician periodically checks the outdoor unit, the R-32 charge and the flow of the drains, and you clear the snow around the unit after every storm.
On the grant side, Hydro-Québec's LogisVert list of October 27, 2026 shows $1,180 for this system. We help you put the application together; Hydro-Québec sets eligibility under its rules at the time of installation.
This 3-zone system suits semi-detached owners who want to heat and cool the living area and both bedrooms without ducts, those who only have room outside for a single machine, and young families who want to keep a zone in reserve for the basement. As an option, Wi-Fi lets you start cooling the living area as you leave the office.
Boucherville, Sainte-Julie and the whole South Shore: your semi-detached house in three zones
Call us at 514 316-2973 or request your free quote. We look at the free side wall, the yard, the electrical panel and the three rooms to equip, and we propose the outdoor unit location that is most respectful of the neighbourhood. Our refrigeration technicians work under the RBQ licence of AirGreen, an HVAC contractor and AIRSTAGE Elite Plus installer that installs GENERAL AIRSTAGE and Fujitsu AIRSTAGE systems all over the South Shore, in Longueuil, Montreal and Laval, as well as on the North Shore.
If your neighbour already has a heat pump, mention it: we will take it into account when placing yours.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 23,600 BTU/h at −8 °C, 24,000 at −15 °C.
How many heads can I connect?
Up to 4 on this outdoor unit. This product is configured for 3 heads.
How much is the LogisVert grant?
$1,180 according to Hydro-Québec’s list of October 27, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, ID 3627394. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.
Down to what temperature does it heat?
Down to −15 °C.
Is it noisy?
Indoors, the reference head goes down to 21 dB(A). Outdoors, 56 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.