GENERAL AIRSTAGE Aquila R32 QuadZone Heat Pump | 36,000 BTU | Montreal, Laval, South Shore, North Shore
The GENERAL AIRSTAGE Aquila R32 36 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. it delivers 23,600 BTU/h at −8 °C, heats down to −15 °C and qualifies for a $1,180 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Compared with the 141 multi-zone systems of 36,000 BTU we sell. Every number on this page carries its source.
Before the numbers, watch it run.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 66 % of its rated capacity.
Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.
It slows down, it speeds up: the certified modulation range
Light bar: from minimum to maximum capacity. Dark mark: the rated value.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.
A grant you can calculate, not guess.
The capacity at −8 °C comes from Hydro-Québec’s list of October 27, 2026. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).
Where it ranks among same-size multi-zone systems.
Compared with the 141 multi-zone systems of 36,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.
Against three other brands in its class.
Same rated size, other manufacturers. Pick the opponent.
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
GENERAL AIRSTAGE Aquila 4-Zone Heat Pump, 36,000 BTU: four bedrooms, a single outdoor unit and not one duct, by AirGreen
Four bedrooms, four people, four ways of sleeping. In a Boisbriand or Rosemère house, that is often the portrait of the upper floor: the parents' bedroom, two children's rooms and a fourth that serves as an office or a sewing room. Equipping each one with an independent wall-mounted heat pump would mean four outdoor units hanging on the walls. Running ducts would mean opening ceilings and sacrificing closets. The multi-zone system avoids both.
The GENERAL AIRSTAGE Aquila 4-zone 36,000 BTU connects four wall-mounted heads, here in a 7,000 + 7,000 + 7,000 + 7,000 BTU configuration, to a single outdoor unit, the AOUH36KWAS4. It is the same system as the Fujitsu AIRSTAGE Aquila 4-zone that uses this compressor: same manufacturer, known as GENERAL Inc. since January 1, 2026, same AHRI certificate 215447689, same certified values, same warranty, with the compressor and parts covered for 12 years and labour covered for 6 years.
A clear façade is often what owners notice first. The four refrigerant lines converge on a single machine, placed at the back or on the side, and the front of the house stays the way you like it, without a cabinet under every window.
GENERAL or Fujitsu AIRSTAGE: the same machine
On the outdoor unit's nameplate, you will read GENERAL or Fujitsu depending on the shipment, because the Fujitsu brand is being phased out gradually and the same machine is sold under both names during the transition. The origin of the change is financial: in August 2025, Fujitsu General passed into the hands of Paloma Rheem Holdings, which has held Rheem since 1988, then Fujitsu General Limited became GENERAL Inc. on January 1, 2026. Kawasaki, Japan, still houses the head office and the R&D centre; the factories have not changed, any more than the AIRSTAGE products, their model numbers or the warranty program.
The GENERAL name dates from 1946. Rheem Canada has sold these products across the country since February 2026, and Groupe Master remains AirGreen's distributor. We keep both pages online because your quote, your warranty and your parts do not depend on the logo: the table below shows it line by line.
| Specification | GENERAL AIRSTAGE | Fujitsu AIRSTAGE |
|---|---|---|
| Outdoor unit | AOUH36KWAS4 | AOUH36KWAS4 |
| Zones | 4 (maximum 4) | 4 (maximum 4) |
| Heads in this configuration | 7,000 + 7,000 + 7,000 + 7,000 BTU | 7,000 + 7,000 + 7,000 + 7,000 BTU |
| Compatible indoor units | ASUH07KPAS, ASUH09KPAS, ASUH12KPAS, ASUH15KPAS, ASUH18KPAS, ASUH24KPAS | ASUH07KPAS, ASUH09KPAS, ASUH12KPAS, ASUH15KPAS, ASUH18KPAS, ASUH24KPAS |
| AHRI certificate | 215447689 | 215447689 |
| Compressor capacity | 36,000 BTU | 36,000 BTU |
| Refrigerant | R-32 | R-32 |
| Power supply | 208/230 V | 208/230 V |
| SEER2 | 22.0 | 22.0 |
| HSPF2 | 10.0 | 10.0 |
| EER2 | 12 | 12 |
| Heating capacity at −8 °C | 23,600 BTU | 23,600 BTU |
| COP at −8 °C | 3.10 | 3.10 |
| Heating capacity at −15 °C | 24,000 BTU | 24,000 BTU |
| COP at −15 °C | 2.20 | 2.20 |
| Heats down to | −15 °C | −15 °C |
| ENERGY STAR | Yes | Yes |
| Cold climate (ENERGY STAR) | No | No |
| ENERGY STAR ID | 3627394 | 3627394 |
| Outdoor unit dimensions (W × D × H, in) | 32.31 x 12.38 x 34.81 | 32.31 x 12.38 x 34.81 |
| Outdoor sound level | 56.0 dB(A) | 56.0 dB(A) |
| Wi-Fi | Optional | Optional |
| LogisVert grant (Hydro-Québec, list of October 27, 2026) | $1,180 | $1,180 |
| Warranty (compressor · parts · labour, years) | 12 · 12 · 6 | 12 · 12 · 6 |
| Manufacturer | GENERAL Inc. (Kawasaki, Japan) | GENERAL Inc. (Kawasaki, Japan) |
| Product page | This page | Fujitsu AIRSTAGE Aquila 4-zone 36,000 BTU |
The Fujitsu version is described on its own page: Fujitsu AIRSTAGE Aquila 4-zone 36,000 BTU. Same AOUH36KWAS4, same configuration, same installer.
Four closed bedrooms means a heating load split four ways, and the compressor has to follow every door that closes. Here is what NEEP (ashp.neep.org) has certified under AHRI number 215447689: at −8 °C, 23,600 BTU/h and a COP of 3.1, with a peak of 29,000 BTU/h; at −15 °C, 24,000 BTU/h and a COP of 2.2. Its heating remains guaranteed down to −15 °C.
A typical January morning on the North Shore hovers around −8 °C; at that temperature, the COP of 3.1 gives an efficiency a little more than three times that of a baseboard, which turns each unit of electricity into a single unit of heat. The cold nights of mid-January drop toward −15 °C, and the system loses nothing there compared with −8 °C. Lower still, the bedroom baseboards top up. The HSPF2 of 10.0 gives the measure of the entire heating season; it pairs with the SEER2 of 22.0, its summer counterpart, and with the EER2 of 12.0.
On efficiency, ENERGY STAR awards it the Most Efficient designation: it counts among the most efficient units of the year. The cold-climate designation is missing from its ENERGY STAR listing; its certified performance at −15 °C, however, is there, with the figures to back it up.
The Inverter compressor goes down to 11,000 BTU/h, the minimum NEEP certifies for it: it modulates its speed according to the number of bedrooms calling rather than running flat out. Outside, the outdoor unit is measured at 56.0 dB(A), and we place it on the side opposite the bedrooms. As for the refrigerant, it is R-32: a global warming potential of 675 according to ENERGY STAR, where R-410A shows 2,088.
Four 7,000 BTU heads, one per bedroom: that is the configuration on this page. A larger master bedroom or a very sunny office can justify another capacity, chosen with us among the compatible indoor units:
- ASUH07KPAS, 7,000 BTU, the standard bedroom;
- ASUH09KPAS, 9,000 BTU, the parents' bedroom;
- ASUH12KPAS, 12,000 BTU, a suite with an ensuite bathroom;
- ASUH15KPAS, 15,000 BTU, a bedroom above the garage, more exposed to the cold;
- ASUH18KPAS, 18,000 BTU, if one of the zones becomes a large living space;
- ASUH24KPAS, 24,000 BTU, for the largest of the rooms.
Four zones is the maximum for this compressor: with this configuration, it is full. We confirm the combination of heads with you during the visit, bedroom by bedroom.
One refrigerant line per head, four in total, and a single outdoor unit: the whole art of the installation lies in grouping those four runs. We place each head on an exterior wall of its bedroom, bring each line out directly behind the head, and gather them in a single line cover that runs down a secondary wall to the outdoor unit. For a bedroom with no wall facing the back or the side, other routes exist; we examine them on site with you.
The outdoor unit goes on a stand that keeps it above the snow, on one side or at the back of the house, where it gets in the way of neither the windows nor the view from the street. The condensate drains flow by gravity to the outside; a condensate pump is needed only for a head with no direct access to an exterior wall. A dedicated electrical circuit powers it from the panel. And since there are no ducts at all, there is no bulkhead in the ceilings and no grille in the floors.
With four heads, maintenance is shared: each occupant takes out the indoor filters of their own bedroom, without tools, and rinses them with water. That is the habit that keeps airflow and efficiency up. The outdoor unit, for its part, gets cleared of snow in winter, and a periodic visit from a refrigeration technician covers the R-32 charge, the coil and the drains.
According to Hydro-Québec's LogisVert list dated October 27, 2026, this system is associated with an amount of $1,180. We put the application together with you; it is Hydro-Québec that confirms eligibility under its rules at the time of the work.
This 4-zone system is aimed at four-bedroom families who want one temperature per bedroom, owners who refuse to see four outdoor units on their walls, and those who want cooling upstairs without ductwork. One remote per bedroom, one setpoint per occupant. Add Wi-Fi, offered as an option, if you want to switch off the heat remotely in the room of a student who is away for the week.
Boisbriand, Rosemère and the whole North Shore: four zones for your four bedrooms
Call 514 316-2973 or request a free quote. We walk through the upper floor, we measure each bedroom and we find with you the best spot for the outdoor unit. Our territory covers the North Shore, Laval, Montreal, Longueuil and the South Shore, served by AirGreen, an RBQ-licensed HVAC contractor and AIRSTAGE Elite Plus installer of GENERAL AIRSTAGE and Fujitsu AIRSTAGE systems.
Also let us know which bedrooms sit above the garage or face due south: those are the ones that will decide the capacities.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 23,600 BTU/h at −8 °C, 24,000 at −15 °C.
How many heads can I connect?
Up to 4 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$1,180 according to Hydro-Québec’s list of October 27, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, ID 3627394. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.
Down to what temperature does it heat?
Down to −15 °C.
Is it noisy?
Indoors, the reference head goes down to 21 dB(A). Outdoors, 56 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.