AirGreenELIOS
ELIOS · Ducted unitsThe ELIOS space at AirGreenSold and installed by AirGreen across Greater Montreal.
Choose my ducted unit
e-Match R-454B, 245 mmData checked Oct. 26, 2026

ELIOS ducted heat pumps · Greater Montreal

245 mm high, 0.8 in of pressure: the ELIOS ducted unit heats two or three rooms through short ducts.

Four R-454B sizes, 9,000 to 24,000 BTU/h, built-in pump, vertical installation possible, wired Wi-Fi controller in the box. The older R-410A ducted units, up to 60,000, are still shown.

The ducted unit in four numbers

245 mmhigh (R-454B)
0.8 inof external static pressure
28.5 dB(A)at the lowest, R-454B 9,000
$2,544highest LogisVert (24,000)

ELIOS SE1 submittals (06.26), DYK bulletins; Hydro-Québec list of Oct. 25, 2026.

11ELIOS ducted listings
9,000 –60,000 BTU/h nominal, from the smallest to the largest
20best certified SEER2 on this page
−25 °Ccoldest certified heating point (NEEP)
$2,544 highest LogisVert amount, Hydro-Québec list of Oct. 25, 2026
AirGreen × ELIOSe-Match ducted245 mm high0.8 in staticSold and installed by AirGreen

The essentials

What the ELIOS ducted unit allows in a ceiling or a closet.

Drawn from the June 2026 SE1 submittals, the “Did you know” bulletins and the ELIOS manual.

245 mm

Height of all four R-454B ducted units.

SUB_E_DHRA09 to 24
0 to 0.8 in

External static pressure, with several selectable profiles (factory setting SP1) and a constant-airflow mode.

DYK_E_011526
Vertical

Vertical installation possible, upflow only, by turning the pump 90°.

DYK_E_121725
55 cm

Lift of the built-in condensate pump, per the manual text.

ISM_G_DHRDHL_0, p. 24
Wi-Fi included

The wired wall controller with Wi-Fi ships with the unit; it is the one that sets static pressure.

SUB_E_DHRA09; DYK_E_011526
28.5 dB(A)

Lowest level published for the R-454B 9,000.

SUB_E_DHRA09 (SE1)
Return of your choice

The ventilation panel and the return flange are interchangeable.

ISM_G_DHRDHL_0, p. 22
Fresh air

The ducted unit has a fresh-air inlet.

SUB_E_DHRA09, p. 3
1 m

Minimum recommended duct length between the unit and the grille.

ISM_G_DHRDHL_0, p. 21
20.0

SEER2 of the R-454B 18,000, the best of the four; HSPF2 region V of 9.0 on the 9,000.

NEEP
12,400

BTU/h certified at −25 °C for the R-454B 24,000.

NEEP
Leak sensor

Every R-454B ducted unit has a built-in refrigerant detection sensor.

SE1 submittals; MAT_E_R454BX_1
0.32 to 0.8 in

Static pressure of the older R-410A ducted units: 0.32 (9,000, 12,000), 0.40 (18,000), 0.64 (24,000 to 48,000), 0.8 (60,000).

R-410A E25 and E18 submittals
$1,092 to $2,544

LogisVert for the R-454B ducted units listed on Oct. 25, 2026; the 9,000 is not.

Hydro-Québec list
Sold and installed

By AirGreen, ducts and grilles included in the quotation.

The lines

The current R-454B ducted unit and the older R-410A.

Counts and amounts read live.

The duel

R-454B or R-410A at the same capacity.

Pick a capacity: certified heat, cold, SEER2, sound and LogisVert.

AirGreen × ELIOS

A hidden ELIOS ducted unit, a local team for the ducts.

ELIOS publishes the height, the pressure and the allowed positions. AirGreen plans the ducts and grilles.

ELIOS

What ELIOS brings

  • 245 mmHigh, four sizes.
  • 0.8 inExternal static pressure.
  • Wi-Fi includedWired controller in the box.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenAcross Greater Montreal.
  • Free on-site estimateThe quotation names the ELIOS model that fits and the LogisVert amount Hydro-Québec lists.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: two or three rooms heated and cooled, with no visible unit, installed by AirGreen.

The ELIOS ducted shop

All our ELIOS ducted units, right below.

One listing per capacity and refrigerant.

ELIOS

Everything to know

The ELIOS ducted unit up close: height, noise, cold.

What to know before hiding a heat pump in a ceiling.

Every model, side by side

ELIOS ducted units, side by side.

Each row is a ducted unit with its outdoor unit, under one AHRI number. The R-410A 60,000 has no NEEP record read.

ModelHeat at −8 °CMax at −15 °CColdest certified pointSEER2HSPF2 (V)SoundLogisVertCertification
R-454B e-Match ducted
R-454B e-Match ducted · 9,000 BTU/hESHEA09C2AN1 + GDHRA09C2AS19,300 BTU/h8,300 BTU/h−25 °C · 5,200 BTU/h19.7928.5–30.5 dB(A)—AHRI 216046626 · ENERGY STAR 3799017, cold climate
R-454B e-Match ducted · 12,000 BTU/hESHEA12C2AN1 + GDHRA12C2AS19,100 BTU/h8,900 BTU/h−25 °C · 5,200 BTU/h19.5831–33.5 dB(A)$1,092AHRI 216046627 · ENERGY STAR 3799018, cold climate
R-454B e-Match ducted · 18,000 BTU/hESHEA18C2AN1 + GDHRA18C2AS114,900 BTU/h14,200 BTU/h−25 °C · 8,500 BTU/h208.833–40 dB(A)$1,788AHRI 216046628 · ENERGY STAR 3799019, cold climate
R-454B e-Match ducted · 24,000 BTU/hESHEA24C2AN1 + GDHRA24C2AS121,200 BTU/h19,000 BTU/h−25 °C · 12,400 BTU/h198.535.5–43 dB(A)$2,544AHRI 216046629 · ENERGY STAR 3799020, cold climate
R-410A e-Match ducted
R-410A e-Match ducted · 9,000 BTU/hDEA09HOS25230E8 + DUA09HIDU230X57,700 BTU/h8,000 BTU/h−25 °C · 3,900 BTU/h19.2827–33.5 dB(A)—AHRI 207742445 · ENERGY STAR 3544064, cold climate
R-410A e-Match ducted · 12,000 BTU/hDEA12HOS25230E8 + DUA12HIDU230X59,300 BTU/h8,400 BTU/h−25 °C · 6,200 BTU/h197.831–38 dB(A)—AHRI 207742446 · ENERGY STAR 3544065, cold climate
R-410A e-Match ducted · 18,000 BTU/hDEA18HOS25230E8 + DUA18HIDU230X512,600 BTU/h13,000 BTU/h−25 °C · 6,500 BTU/h208.235.5–42 dB(A)$630AHRI 207742447 · ENERGY STAR 3544066
R-410A e-Match ducted · 24,000 BTU/hDEA24HOS25230E8 + DUA24HIDU230X520,000 BTU/h20,000 BTU/h−25 °C · 10,500 BTU/h198.837–44 dB(A)$2,400AHRI 207742448 · ENERGY STAR 3544067, cold climate
R-410A e-Match ducted · 36,000 BTU/hDEA36HOS18230S5 + DUA36HIDU230X525,000 BTU/h22,000 BTU/h−25 °C · 15,500 BTU/h15.8740.5–48 dB(A)—AHRI 207742449
R-410A e-Match ducted · 48,000 BTU/hDEA48HOS18230S5 + DUA48HIDU230X534,000 BTU/h34,000 BTU/h−25 °C · 26,000 BTU/h15.17.349–52 dB(A)—AHRI 207742450
R-410A e-Match ducted · 60,000 BTU/h———————no NEEP or ENERGY STAR record

Heat at −8 °C, maximum at −15 °C and coldest point: NEEP registry (ashp.neep.org), read by AHRI number on Oct. 14, 2026. SEER2 and HSPF2 region V: same source. LogisVert amounts: Hydro-Québec’s list of eligible heat pumps, Oct. 25, 2026. Sound: ELIOS technical documents. A dash means “not published”.

The thermometer

From 8 °C to −25 °C, unit by unit.

NEEP-certified capacity: slide toward the cold.

The sound meter

A hidden ducted unit, how loud?

Levels from the ELIOS documents, lowest to highest speed, on the Québec.ca sound scale.

Did you know

Eight details from the ELIOS ducted documents.

Tap a card to flip it.

Tech corner

The four R-454B ducted units, row by row.

ELIOS submittals. System MCA and protection; a dash means “not published in the documents read”.

SizePower supplyMCA / max. protectionLiquid / gas linesMax. length / heightIndoor unit W×H×DHeats down to (ELIOS)
9,000 BTU/h208-230 V · 1 Ph · 60 Hz12 A / 15 A1/4 in / 3/8 in—700×245×750 mm−25 °C
12,000 BTU/h208-230 V · 1 Ph · 60 Hz12 A / 15 A1/4 in / 3/8 in—700×245×750 mm−25 °C
18,000 BTU/h208-230 V · 1 Ph · 60 Hz18 A / 20 A1/4 in / 1/2 in—1,000×245×750 mm−25 °C
24,000 BTU/h208-230 V · 1 Ph · 60 Hz24 A / 25 A3/8 in / 5/8 in—1,000×245×750 mm−25 °C

LogisVert · Hydro-Québec

LogisVert on ELIOS ducted units.

5 of the 11 listings on this page appear on Hydro-Québec’s list of eligible heat pumps (Oct. 25, 2026). The amount follows the certified heating capacity at −8 °C, size by size.

ModelCapacity at −8 °CRateAmount
R-454B e-Match ducted · 24,000 BTU/h21,200 BTU/h$120 per 1,000 BTU/h, cold climate$2,544
R-454B e-Match ducted · 18,000 BTU/h14,900 BTU/h$120 per 1,000 BTU/h, cold climate$1,788
R-454B e-Match ducted · 12,000 BTU/h9,100 BTU/h$120 per 1,000 BTU/h, cold climate$1,092
R-410A e-Match ducted · 24,000 BTU/h20,000 BTU/h$120 per 1,000 BTU/h, cold climate$2,400
R-410A e-Match ducted · 18,000 BTU/h12,600 BTU/h$50 per 1,000 BTU/h$630

How Hydro-Québec computes it

The amount follows the certified heating capacity at −8 °C: $120 per 1,000 BTU/h for a cold-climate ENERGY STAR heat pump, $50 for a standard ENERGY STAR heat pump.

  • Outdoor unit of 12,000 BTU/h or more.
  • Capped at 100% of the cost of the work.
  • Apply within 9 months of the installation.

Source: Hydro-Québec, LogisVert participation guide, residential customers, version 1.10 of September 15, 2026. Have Hydro-Québec confirm your case. Our LogisVert page.

Hydro-Québec does no phone or door-to-door solicitation for LogisVert. The amount shown is indicative: only Hydro-Québec confirms the aid granted.

Questions

Questions about ELIOS ducted units.

Where does a ducted unit go?

In a drop ceiling, a closet or a heated attic space: it is 245 mm high and can also stand vertically, upflow. The grilles go in each room served.

How many rooms can one ducted unit serve?

It depends on the capacity and the ducts; 0.8 in of pressure allows short runs to two or three neighbouring rooms. We do the room-by-room calculation.

Is Wi-Fi included?

Yes on the R-454B: the wired wall controller with Wi-Fi is in the box, and it is the one that sets static pressure.

Why keep the R-410A on the page?

For owners who have one and for comparison. The June 2026 ELIOS bulletin announces the R-410A phase-out in 2026.

What warranty?

ELIOS publishes 1 year on parts and 5 years on the compressor, with optional 10-year coverage. ELIOS publishes no labour warranty.

AirGreen × ELIOSe-Match ducted245 mm high0.8 in staticSold and installed by AirGreen

AirGreen × ELIOS · your project

A ducted unit for a few rooms? We plan the ducts.

We look at the available space, the duct and grille route, the outdoor unit and the panel, then we price it.

AirGreen · Air Conditioning & Heating

RBQ licence 5645-9605-01, subclasses 15.8 (ventilation), 15.10 (refrigeration) and 16 (electrical).

Free on-site estimate across Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.

Gas, oil and hydronic work is done by a partner who holds the required licence.

514 316-2973 · sales@airgreen.ca

Sources checked on Oct. 26, 2026

  1. ELIOS, e-Match R-454B SE1 submittals (06.26): SUB_E_KHRA09/12/18, SUB_E_QHRA24, SUB_E_OHRA12/18, SUB_E_DHRA09-24, SUB_E_FHRA12, eliosprotech.com.
  2. ELIOS, e-Match brochure (Elios_e-Match_202509_V02).
  3. ELIOS, e-Match R-410A submittals (E25, Sept. 2024; E18, June 2024).
  4. ELIOS, TRS_E_410454_1 bulletin (JUNE-19-26).
  5. ELIOS, ISM_G_DHRDHL_0 manual and “Did you know” bulletins DYK_E_121725 and DYK_E_011526.
  6. NEEP, Cold Climate Air Source Heat Pump List, ashp.neep.org, records read by AHRI number on Oct. 14, 2026.
  7. ENERGY STAR, Certified Air-Source Heat Pumps dataset (data.energystar.gov, w7cv-9xjt), Canadian market, read Oct. 14, 2026.
  8. Hydro-Québec, LogisVert eligible heat pump list, owner, existing home, file of Oct. 25, 2026 (ELIOS rows identical to Oct. 14).
  9. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, Sept. 15, 2026.
  10. Québec.ca, “Mesure du bruit”, updated June 16, 2022 (dBA sound scale).
  11. ENERGY STAR, “Properly Sized Room Air Conditioners”, energystar.gov (sizing chart), read Oct. 26, 2026.

Amounts shown are estimates; only the responsible organizations confirm the aid granted. Product availability is confirmed at the time of the quotation.