AirGreen × GENERAL AIRSTAGE
Sold and installed by AirGreen.
Montreal, Laval, Longueuil, the North Shore and the South Shore.
GENERAL AIRSTAGE // Ducted
GENERAL ducted heat pump, R-32 or R-410A: which one fits your ceiling?
The 7 R-32 ARUH, from 12,000 to 48,000 BTU, hide in 300 mm above the ceiling, and air flows through grilles. Also available: 13 R-410A ducted units, including 198 mm slim ones. In all, 20 listings; it all depends on the ceiling space.
The tool // Ceiling space
How much space above the ceiling, and what size?
The tool opens on 300 mm and 24,000 BTU: the R-32 ARUH24KUAS first, then the R-410A ARU24RGLX. Under 300 mm, the R-410A slim units from 9,000 to 18,000 BTU remain.
Matching listings: 2
ARUH 12,000 BTU ARUH12KUAS
R-32 · body 300 × 700 × 700 mm · submittal 12KUAS1R
Static pressure 0.12 to 0.80 in. WG · built-in drain pump · 30 m of line at most
At −15 °C: 15,500 BTU/h rated heating (NEEP) · AHRI 215434556
LogisVert $1,284indicative amountARUH 18,000 BTU ARUH18KUAS
R-32 · body 300 × 1,000 × 700 mm · submittal 18KUAS1R
Static pressure 0.12 to 0.80 in. WG · built-in drain pump · 30 m of line at most
At −15 °C: 17,100 BTU/h rated heating (NEEP) · AHRI 215434557
LogisVert $1,728indicative amountARUH 24,000 BTU ARUH24KUAS
R-32 · body 300 × 1,000 × 700 mm · submittal 24KUAS1R
Static pressure 0.12 to 0.80 in. WG · built-in drain pump · 50 m of line at most
At −15 °C: 23,600 BTU/h rated heating (NEEP) · AHRI 215434558
LogisVert $2,136indicative amountARUH 30,000 BTU ARUH30KUAS
R-32 · body 300 × 1,000 × 700 mm · submittal 30KUAS1R
Static pressure 0.12 to 0.80 in. WG · built-in drain pump · 50 m of line at most
At −15 °C: 28,000 BTU/h rated heating (NEEP) · AHRI 215434559
LogisVert $2,544indicative amountARUH 36,000 BTU ARUH36KUAS
R-32 · body 300 × 1,400 × 700 mm · submittal 36KUAS1R
Static pressure 0.12 to 0.80 in. WG · built-in drain pump · 50 m of line at most
At −15 °C: 31,000 BTU/h rated heating (NEEP) · AHRI 215434560
LogisVert $3,048indicative amountARUH 42,000 BTU ARUH42KUAS
R-32 · body 300 × 1,400 × 700 mm · submittal 42KUAS1R
Static pressure 0.12 to 0.72 in. WG · built-in drain pump · 75 m of line at most
At −15 °C: 37,000 BTU/h rated heating (NEEP) · AHRI 215812202
LogisVert $3,840indicative amountARUH 48,000 BTU ARUH48KUAS
R-32 · body 300 × 1,400 × 700 mm · submittal 48KUAS1R
Static pressure 0.12 to 0.72 in. WG · built-in drain pump · 75 m of line at most
At −15 °C: 38,500 BTU/h rated heating (NEEP) · AHRI 215812203
LogisVert $4,320indicative amountARU RGLX 12,000 BTU ARU12RGLX
R-410A · body 300 mm high, 700 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
No AHRI numberARU RGLX 18,000 BTU ARU18RGLX
R-410A · body 300 mm high, 1,000 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
At −15 °C: 17,900 BTU/h rated heating (NEEP) · AHRI 202534923
LogisVert $635indicative amountARU RGLX 24,000 BTU ARU24RGLX
R-410A · body 300 mm high, 1,000 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
At −15 °C: 22,200 BTU/h rated heating (NEEP) · AHRI 202537547
LogisVert $865indicative amountARU RGLX 30,000 BTU ARU30RGLX
R-410A · body 300 mm high, 1,000 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
No AHRI numberARU RGLX 36,000 BTU ARU36RGLX
R-410A · body 300 mm high, 1,400 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
No AHRI numberARU RGLX 42,000 BTU ARU42RGLX
R-410A · body 300 mm high, 1,400 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
No AHRI numberARU RGLX 48,000 BTU ARU48RGLX
R-410A · body 300 mm high, 1,400 mm wide, per our product page
Static pressure up to 0.80 in. WG · built-in drain pump
No AHRI numberADUH 9,000 BTU ADUH09LUAS1
R-410A · body 198 × 700 × 620 mm · 17 kg
Static pressure 0 to 0.36 in. WG · 353 CFM at high speed
Multi-zone indoor unit: GENERAL lists it in its multi-zone indoor-unit table
No AHRI numberADUH 12,000 BTU ADUH12LUAS1
R-410A · body 198 × 700 × 620 mm · 17 kg
Static pressure 0 to 0.36 in. WG · 382 CFM at high speed
Multi-zone indoor unit: GENERAL lists it in its multi-zone indoor-unit table
No AHRI numberADUH 18,000 BTU ADUH18LUAS1
R-410A · body 198 × 900 × 620 mm · 20 kg
Static pressure 0 to 0.36 in. WG · 553 CFM at high speed
Multi-zone indoor unit: GENERAL lists it in its multi-zone indoor-unit table
No AHRI numberARU RLF 9,000 BTU ARU9RLF
R-410A · body 198 mm high, 700 mm wide
Height: ARU7RLF submittal, same family; width: our product page
Multi-zone indoor unit: GENERAL names it among the indoor units of its four- and five-room systems
No AHRI numberARU RLF 12,000 BTU ARU12RLF
R-410A · body 198 mm high, 700 mm wide
Height: ARU7RLF submittal, same family; width: our product page
Multi-zone indoor unit: GENERAL names it among the indoor units of its four- and five-room systems
No AHRI numberARU RLF 18,000 BTU ARU18RLF
R-410A · body 198 mm high, 900 mm wide
Height: ARU7RLF submittal, same family; width: our product page
Multi-zone indoor unit: GENERAL names it among the indoor units of its four- and five-room systems
No AHRI number
No GENERAL ducted unit online matches both choices. The R-32 ARUH needs 300 mm, from 12,000 to 48,000 BTU; the 198 mm slim units, R-410A, run from 9,000 to 18,000 BTU. A unit hung below the ceiling or a wall unit may also do: we look at this on site.
Body heights: GENERAL's KUAS1R submittals for the ARUH (300 mm), the multi-zone indoor-unit table for the ADUH (198 mm), the ARU7RLF submittal for the ARU RLF family (198 mm); for the ARU RGLX, whose dimensions GENERAL does not publish in the documents read, our product page (300 mm). The tool compares the body alone: hangers, drain slope and duct fittings need a little more, and we measure on site.
The 20 ducted units online
Price by quote.
Compare // At 18,000 BTU
ARUH or ADUH: 102 mm apart, one zone or multi-zone
ARUH 18,000 ARUH18KUAS
- System
- one zone, with the AOUH18KUAS1
- Refrigerant
- R-32
- Body, H × W × D
- 300 × 1,000 × 700 mm
- Weight
- 41 kg
- Airflow, high speed
- 618 CFM
- Static pressure
- 0.12 to 0.80 in. WG
- Indoor sound, high speed
- 34 dB(A)
- Drain pump
- built in
- LogisVert, indicative
- $1,728
ADUH 18,000 ADUH18LUAS1
- System
- multi-zone head
- Refrigerant
- R-410A
- Body, H × W × D
- 198 × 900 × 620 mm
- Weight
- 20 kg
- Airflow, high speed
- 553 CFM
- Static pressure
- 0 to 0.36 in. WG
- Indoor sound, high speed
- 32 dB(A)
- Drain pump
- not stated
- LogisVert, indicative
- no AHRI number of its own
The ADUH, a multi-zone head, is 102 mm shorter and weighs half as much. The ARUH, a one-zone system, pushes air against more than twice the static pressure (0.80 against 0.36 in. WG), has a built-in drain pump and an AHRI number.
The families // Slim and medium static
Four ducted families, two heights
Values as GENERAL prints them in its submittals and multi-zone table, except the ARU RGLX height, from our product page; the ARU RGLX pressure, pump and 246 ft come from GENERAL's release of March 11, 2019.
| Family | Refrigerant | System | Sizes | Body height | Static pressure | Drain pump | Line set, at most |
|---|---|---|---|---|---|---|---|
| ARUH..KUAS | R-32 | one zone | 12,000 to 48,000 BTU | 300 mm | 0.12 to 0.80 in. WG; 0.12 to 0.72 at 42,000 and 48,000 BTU | built in | 30 m (12,000, 18,000), 50 m (24,000 to 36,000), 75 m (42,000, 48,000) |
| ARU..RGLX | R-410A | one zone | 12,000 to 48,000 BTU | 300 mm, our product page | up to 0.80 in. WG | built in | up to 75 m (246 ft) |
| ADUH..LUAS1 | R-410A | multi-zone head | 9,000, 12,000 and 18,000 BTU | 198 mm | 0 to 0.36 in. WG | not stated | not stated |
| ARU..RLF | R-410A | multi-zone head | 9,000, 12,000 and 18,000 BTU | 198 mm (ARU7RLF) | not printed | none on the ARU7RLF sheet, rigid PVC hose | not stated |
GENERAL // Did you know
Three things GENERAL writes about its ducted units
Did you know · Pressure
Does the ARUH measure its own ducts?
Did you know · Air intake
Where does the 30,000 or 48,000 BTU ARUH take in air?
Did you know · The drain
How high does the ARU RGLX pump lift condensate?
LogisVert
LogisVert for a ducted unit
Of the 20 listings, 9 carry an AHRI number. Under the LogisVert guide v1.10 (September 15, 2026), the combination must be on the Canadian ENERGY STAR list: $120 per 1,000 BTU/h of heating at −8 °C with the cold-climate mention, as for the R-32 ARUH, or $50 without, as for the R-410A ARU18RGLX and ARU24RGLX.
Indicative amounts: ARUH12KUAS $1,284; ARUH18KUAS $1,728; ARUH24KUAS $2,136; ARUH30KUAS $2,544; ARUH36KUAS $3,048; ARUH42KUAS $3,840; ARUH48KUAS $4,320; ARU18RGLX $635; ARU24RGLX $865.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about GENERAL ducted units
Slim or medium-static ducted: what is the difference?
Height, static pressure and system. The R-32 ARUH and the R-410A ARU RGLX are 300 mm high, from 12,000 to 48,000 BTU, each with its own outdoor unit; the ARUH handles up to 0.80 in. WG. The slim ADUH and ARU RLF, R-410A, are 198 mm high, from 9,000 to 18,000 BTU, and connect to a multi-zone unit; the ADUH handles 0 to 0.36 in. WG.
How far can an ARUH’s outdoor unit go?
GENERAL prints 30 m of line at most at 12,000 and 18,000 BTU, 50 m from 24,000 to 36,000 and 75 m at 42,000 and 48,000. The length is measured along the real line route, which we survey during the visit.
Condensate from a ducted unit: pump or slope?
The R-32 ARUH and the ARU RGLX have a built-in drain pump. For the slim units, GENERAL's table does not mention a pump for the ADUH, and the ARU7RLF submittal only shows a rigid PVC drain hose. Without a pump, the drain runs down by gravity: we check on site whether one must be added and plan its route before installation.
What size of ducted unit?
It is chosen on site, from the rooms the ducts will serve, the insulation of the house and the duct route. We come and measure, then propose a size and a family.
A heat pump hidden in the ceiling, installed by AirGreen.
We come and measure the space above the ceiling, the duct route and the drain slope, then give you the AHRI number and indicative LogisVert amount of the ducted unit you choose.
Sold and installed by AirGreen.
The whole house on ducts, R-32: the Centauri · An R-32 ceiling cassette · An R-32 ceiling-suspended unit · GENERAL AIRSTAGE
Sources
Where the numbers come from
- GENERAL, 12KUAS1R and 18KUAS1R (20251015A), 24KUAS1R, 30KUAS1R, 36KUAS1R, 42KUAS1R and 48KUAS1R (20250409A) submittals, p. 1 and 2: ARUH dimensions, airflow, static pressure, sound and line set, read November 5, 2026.
- GENERAL, "Specifications of Indoor Units" page (multi-zone): ADUH09LUAS1, ADUH12LUAS1 and ADUH18LUAS1, read November 5, 2026.
- GENERAL, ARU7RLF submittal ("Submittal Data"), p. 1 of 4 (ARU RLF family).
- GENERAL, release on the RGLX medium-static ducted units, March 11, 2019.
- GENERAL, four- and five-room multi service manual (AOU36RLXFZH, AOU45RLXFZ), for the ARU..RLF.
- NEEP listings 385494, 385495, 388253, 388254, 388255, 388256, 388257, 438630 and 438631, checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2634275, 2634293, 3627239, 3627240, 3627241, 3627242, 3627243, 3630315 and 3630316, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.