AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // Centauri · R-32

GENERAL Centauri central heat pump: 1 to 4 tons, one multi-position air handler

6 systems, each an AOUH..KUAS1 outdoor unit with an AMUH air handler, from 12,000 to 48,000 BTU. The air handler installs up-flow, horizontal or down-flow (optional kit), and the published heating limit is −21 °C.

6listings online
6sizes, 12,000 to 48,000 BTU
−21 °Cpublished heating limit
75 mof line set at most, at 48,000
$4,464highest LogisVert, at 48,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

The tool // Installation sheet

Your Centauri size, from the air handler to the line set

The tool opens on the 36,000: medium cabinet, 50 m of line set at most. Move to the 48,000 and the line set goes up to 75 m.

Size

Centauri 36,000 AOUH36KUAS1 + AMUH36KUAS · 3 tons

Air handler
AMUH36KUAS, medium cabinet, 1,219 × 533 × 533 mm (H × W × D)
Filter base · downflow kit
86ET001 (20 × 20 in.) · UTD-DFMMB1, optional
External static pressure
0.2 to 0.8 in. WG
Airflow, high speed
1,207 CFM
Indoor sound in cooling, quiet to high speed
31 to 44 dB(A)
Line set, maximum · pre-charged for
50 m (164 ft) · 20 m
Maximum height difference · R-32 charge
30 m (98 ft) · 4 lb 7 oz
Heating at 8.3 °C, rated (NEEP)
38,000 BTU/h
At −15 °C, rated · at −21 °C, maximum (NEEP)
32,000 BTU/h · 27,850 BTU/h · COP 2.06
LogisVert, indicative amount
$3,288 · AHRI 217290596

See the Centauri 36,000 BTU listing

Air handler, line set, charge, kits and static pressure: GENERAL's 12, 18, 24, 36 and 48KUAS1M (20251124A) and 30KUAS1M (20250612A) submittals; GENERAL puts the 12,000 to 24,000 sizes in the small cabinet, 30,000 to 48,000 in the medium one. Heating: NEEP listings 375763 to 375768, checked November 5, 2026.

The 6 Centauri systems online

Price by quote.

Compare // 24,000 or 30,000

The 24,000 or the 30,000: the step to the medium cabinet

Centauri 24,000 AOUH24KUAS1 + AMUH24KUAS

Air handler
AMUH24KUAS, small cabinet
Dimensions (H × W × D)
1,092 × 444 × 533 mm
Filter base · downflow kit
86ET0002 (16 × 20 in.) · UTD-DFMSB1
External static pressure
0.08 to 0.80 in. WG
Airflow, high speed
750 CFM
R-32 charge · maximum line set
3 lb 5 oz · 50 m
At −15 °C, rated (NEEP)
24,600 BTU/h
LogisVert, indicative
$2,184

Centauri 30,000 AOUH30KUAS1 + AMUH30KUAS

Air handler
AMUH30KUAS, medium cabinet
Dimensions (H × W × D)
1,219 × 533 × 533 mm
Filter base · downflow kit
86ET001 (20 × 20 in.) · UTD-DFMMB1
External static pressure
0.2 to 0.8 in. WG
Airflow, high speed
1,000 CFM
R-32 charge · maximum line set
4 lb 7 oz · 50 m
At −15 °C, rated (NEEP)
29,400 BTU/h
LogisVert, indicative
$2,664

Between the 24,000 and the 30,000, the Centauri changes cabinet: 1,092 then 1,219 mm high, 444 then 533 mm wide, with another filter base and another downflow kit. The line set stays at 50 m at most.

GENERAL // Did you know

Three things the Centauri submittals say

Did you know · The outdoor unit

Is the Centauri outdoor unit only for air handlers?

Did you know · Heating

Does a 12,000 Centauri heat at 12,000 BTU/h?

Did you know · Connections

Can the AMUH work with an air exchanger?

LogisVert

LogisVert for a Centauri

All six Centauri systems are ENERGY STAR cold climate certified: under the LogisVert guide v1.10 (September 15, 2026), $120 per 1,000 BTU/h of heating at −8 °C, from $1,272 for the 12,000 to $4,464 for the 48,000. The tool gives each size's amount.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about the Centauri

How does it differ from the Centauri XLTH?

The Centauri XLTH keeps the AMUH and changes the outdoor unit, at 30,000, 36,000 and 48,000 BTU; its tool compares the two, point by point, from 8.3 °C to −26 °C.

Can it go on existing ducts?

GENERAL presents the AMUH as an air handler designed for retrofit as well as new construction. What we check in your ducts is explained on the GENERAL electric furnace page.

Is backup heat needed?

The Centauri's published heating limit is −21 °C, and GENERAL states that capacity is not tested outside the published range. The backup options, an electric kit or an existing heater, are on the GENERAL electric furnace page.

Which Centauri size for my house?

That is decided at your home: the area to heat, insulation, windows and the condition of the ducts. We come and see, then suggest a size, from 1 to 4 tons.

AirGreenGENERAL

A Centauri in your home, installed by AirGreen.

We come and see where the air handler goes, your ducts and the route to the outdoor unit, then give you the size, the AHRI number and the indicative LogisVert amount.

Sold and installed by AirGreen.

All GENERAL central heat pumps · The Centauri XLTH, down to −26 °C · Backup heat: electric furnaces

Sources

Where the numbers come from

  1. GENERAL, 12KUAS1M, 18KUAS1M, 24KUAS1M, 36KUAS1M and 48KUAS1M (20251124A) and 30KUAS1M (20250612A) submittals, p. 1 to 4, read November 5, 2026.
  2. GENERAL, AMUH..KUAS page (R-32 multi-position air handler), airstagehvac.com, read November 5, 2026.
  3. NEEP listings 375763, 375764, 375765, 375766, 375767 and 375768, checked November 5, 2026.
  4. ENERGY STAR, Canadian market, records 4428945, 4428946, 4428947, 4428948, 4428949 and 4428950, checked November 5, 2026.
  5. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  6. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.