GENERAL AIRSTAGE // Central heat pump
GENERAL central heat pump: 1 to 4 tons, on your ducts
16 systems, each made of an outdoor unit and a multi-position air handler: the Centauri and Centauri XLTH on R-32, and seven R-410A systems, from 12,000 to 48,000 BTU.
The tool // Tonnage comparator
Your tonnage: every GENERAL central system of that size
The tool opens at 3 tons: four systems, two on R-32 and two on R-410A. At 1 and 1.5 tons, only the Centauri is offered.
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH12KUAS1 | R-32 | −21 °C | 16,100 BTU/h | 19.9 | $1,272 |
1 GENERAL system at 12,000 BTU (1 ton).
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH18KUAS1 | R-32 | −21 °C | 17,300 BTU/h | 19.2 | $1,932 |
1 GENERAL system at 18,000 BTU (1.5 tons).
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH24KUAS1 | R-32 | −21 °C | 24,600 BTU/h | 17.7 | $2,184 |
| 24RGLXM AOU24RGLX | R-410A | −21 °C (outdoor unit, RGLX press release) | not listed | not listed | $0 (not on the Canadian ENERGY STAR list) |
2 GENERAL systems at 24,000 BTU (2 tons).
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH30KUAS1 | R-32 | −21 °C | 29,400 BTU/h | 19.0 | $2,664 |
| Centauri XLTH AOUH30KUAH1 | R-32 | −26 °C | 34,000 BTU/h | 18.8 | $2,520 |
| 30RGLXM AOU30RGLX | R-410A | −21 °C (outdoor unit, RGLX press release) | not listed | not listed | $0 (not on the Canadian ENERGY STAR list) |
| 30LUAH1M AOUH30LUAH1 | R-410A | −26 °C | 33,000 BTU/h | 18.8 | $2,592 |
4 GENERAL systems at 30,000 BTU (2.5 tons).
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH36KUAS1 | R-32 | −21 °C | 32,000 BTU/h | 17.6 | $3,288 |
| Centauri XLTH AOUH36KUAH1 | R-32 | −26 °C | 41,000 BTU/h | 18.3 | $3,024 |
| 36LMAS1 AOUG36LMAS1 | R-410A | not stated | 32,800 BTU/h | 17.1 | $3,528 |
| 36LMAH1M AOUH36LMAH1 | R-410A | −26 °C | not listed | not listed | $0 (not on the Canadian ENERGY STAR list) |
4 GENERAL systems at 36,000 BTU (3 tons).
| System | Refrigerant | Published limit | At −15 °C, rated | SEER2 | LogisVert, indicative |
|---|---|---|---|---|---|
| Centauri AOUH48KUAS1 | R-32 | −21 °C | 41,000 BTU/h | 17.0 | $4,464 |
| Centauri XLTH AOUH48KUAH1 | R-32 | −26 °C | 51,000 BTU/h | 19.0 | $4,080 |
| 48LMAS1 AOUG48LMAS1 | R-410A | not stated | not listed | not listed | $0 (not on the Canadian ENERGY STAR list) |
| 48LMAH1M AOUH48LMAH1 | R-410A | −26 °C | not listed | not listed | $0 (not on the Canadian ENERGY STAR list) |
4 GENERAL systems at 48,000 BTU (4 tons).
Published limits: KUAS1M submittals (Centauri), AMUH..KUAS page (Centauri XLTH), GENERAL's 30LUAH1M, 36LMAH1M and 48LMAH1M pages (−15 °F), RGLX press release of March 11, 2019 (−5 °F); for the 36LMAS1 and 48LMAS1 we found no published limit. At −15 °C and SEER2: ENERGY STAR (Canadian market) and NEEP listings, checked November 5, 2026.
The 16 central heat pumps online
Price by quote.
Compare // At 3 tons
Centauri on R-32 or 36LMAS1 on R-410A?
Centauri 36,000 AOUH36KUAS1
- Refrigerant · air handler
- R-32 · AMUH36KUAS
- At −8.3 °C, rated (ENERGY STAR)
- 27,400 BTU/h
- At −15 °C, rated (NEEP)
- 32,000 BTU/h
- At −21 °C, maximum (NEEP)
- 27,850 BTU/h · COP 2.06
- SEER2 · HSPF2
- 17.6 · 9.8
- LogisVert, indicative
- $3,288
R-410A 36LMAS1 AOUG36LMAS1
- Refrigerant · air handler
- R-410A · AMUG36LMAS
- At −8.3 °C, rated (ENERGY STAR)
- 29,400 BTU/h
- At −15 °C, rated (NEEP)
- 32,800 BTU/h
- At −21 °C, maximum (NEEP)
- 28,830 BTU/h · COP 1.97
- SEER2 · HSPF2
- 17.1 · 8.8
- LogisVert, indicative
- $3,528
At 3 tons both are close at −15 °C: 32,000 BTU/h against 32,800 BTU/h, rated. The Centauri uses R-32 and has the higher SEER2 and HSPF2; the 36LMAS1 has a higher rated output at −8.3 °C, 29,400 against 27,400 BTU/h, hence a slightly higher LogisVert amount.
GENERAL // Did you know
Three things to know about GENERAL central systems
Did you know · Tonnage
Does a "4-ton" unit cool at 48,000 BTU/h?
Did you know · The kits
Does the downflow kit come with the R-32 AMUH?
Did you know · Static pressure
How much static pressure can the R-32 AMUH push into the ducts?
LogisVert
LogisVert, system by system
Of the 16 central systems, 11 are on the Canadian ENERGY STAR list, all with the cold-climate mention: under the LogisVert guide v1.10 (September 15, 2026), $120 per 1,000 BTU/h of heating at −8 °C. The other five, all R-410A, are at $0.
The indicative amounts range from $1,272 (Centauri 12,000) to $4,464 (Centauri 48,000); the tool gives each system's amount.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about GENERAL central heat pumps
R-32 or R-410A?
The Centauri and Centauri XLTH are on R-32, the other seven systems on R-410A. On LogisVert, 5 of the 7 R-410A systems are not on the Canadian ENERGY STAR list and are at $0; all nine Centauri systems are on it, with the cold-climate mention.
Does a central heat pump replace my furnace?
It connects to your ducts through an air handler that takes an electric heater kit: optional on the R-32 AMUH, factory-provided on the R-410A AMUG. Each size's kits are on the GENERAL electric furnace page; we check your ducts on site.
Which tonnage for my house?
It is decided at your home: we look at the area to heat, insulation, windows and the size of your ducts, then suggest a tonnage. The comparator then shows every GENERAL system of that tonnage.
A GENERAL central heat pump on your ducts, installed by AirGreen.
We come and see your ducts and where the air handler and the outdoor unit go, then give you the tonnage, the AHRI number and the indicative LogisVert amount of the system you choose.
Sold and installed by AirGreen.
The Centauri, 1 to 4 tons · The Centauri XLTH, down to −26 °C · GENERAL electric furnaces · Ducted units
Sources
Where the numbers come from
- GENERAL, 12, 18, 24, 36 and 48KUAS1M (20251124A) and 30KUAS1M (20250612A) submittals, read November 5, 2026.
- GENERAL, AMUH..KUAS page, airstagehvac.com; 24RGLXM, 30RGLXM, 36LMAS1, 48LMAS1, 30LUAH1M, 36LMAH1M and 48LMAH1M pages and AMUG24LMAS to AMUG48LMAS pages, GENERAL's legacy product pages, read November 5, 2026.
- GENERAL, press release on the RGLX medium static pressure duct units, March 11, 2019.
- NEEP listings 306745, 306746, 306747, 375763, 375764, 375765, 375766, 375767, 375768, 438527 and 438622, checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2409794, 2409932, 4428945, 4428946, 4428947, 4428948, 4428949, 4428950, 4511772, 4511773 and 4511774, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.