AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // Central heat pump

GENERAL central heat pump: 1 to 4 tons, on your ducts

16 systems, each made of an outdoor unit and a multi-position air handler: the Centauri and Centauri XLTH on R-32, and seven R-410A systems, from 12,000 to 48,000 BTU.

16listings online
1 to 4tons, 12,000 to 48,000 BTU
−26 °Cpublished limit, R-32 Centauri XLTH (and R-410A XLTH)
4systems at 3 tons to compare
$4,464highest LogisVert, at 48,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

The tool // Tonnage comparator

Your tonnage: every GENERAL central system of that size

The tool opens at 3 tons: four systems, two on R-32 and two on R-410A. At 1 and 1.5 tons, only the Centauri is offered.

Tonnage
GENERAL 3-ton central heat pumps
SystemRefrigerantPublished limitAt −15 °C, ratedSEER2LogisVert, indicative
Centauri AOUH36KUAS1R-32−21 °C32,000 BTU/h17.6$3,288
Centauri XLTH AOUH36KUAH1R-32−26 °C41,000 BTU/h18.3$3,024
36LMAS1 AOUG36LMAS1R-410Anot stated32,800 BTU/h17.1$3,528
36LMAH1M AOUH36LMAH1R-410A−26 °Cnot listednot listed$0 (not on the Canadian ENERGY STAR list)

4 GENERAL systems at 36,000 BTU (3 tons).

Published limits: KUAS1M submittals (Centauri), AMUH..KUAS page (Centauri XLTH), GENERAL's 30LUAH1M, 36LMAH1M and 48LMAH1M pages (−15 °F), RGLX press release of March 11, 2019 (−5 °F); for the 36LMAS1 and 48LMAS1 we found no published limit. At −15 °C and SEER2: ENERGY STAR (Canadian market) and NEEP listings, checked November 5, 2026.

The 16 central heat pumps online

Price by quote.

Compare // At 3 tons

Centauri on R-32 or 36LMAS1 on R-410A?

Centauri 36,000 AOUH36KUAS1

Refrigerant · air handler
R-32 · AMUH36KUAS
At −8.3 °C, rated (ENERGY STAR)
27,400 BTU/h
At −15 °C, rated (NEEP)
32,000 BTU/h
At −21 °C, maximum (NEEP)
27,850 BTU/h · COP 2.06
SEER2 · HSPF2
17.6 · 9.8
LogisVert, indicative
$3,288

R-410A 36LMAS1 AOUG36LMAS1

Refrigerant · air handler
R-410A · AMUG36LMAS
At −8.3 °C, rated (ENERGY STAR)
29,400 BTU/h
At −15 °C, rated (NEEP)
32,800 BTU/h
At −21 °C, maximum (NEEP)
28,830 BTU/h · COP 1.97
SEER2 · HSPF2
17.1 · 8.8
LogisVert, indicative
$3,528

At 3 tons both are close at −15 °C: 32,000 BTU/h against 32,800 BTU/h, rated. The Centauri uses R-32 and has the higher SEER2 and HSPF2; the 36LMAS1 has a higher rated output at −8.3 °C, 29,400 against 27,400 BTU/h, hence a slightly higher LogisVert amount.

GENERAL // Did you know

Three things to know about GENERAL central systems

Did you know · Tonnage

Does a "4-ton" unit cool at 48,000 BTU/h?

Did you know · The kits

Does the downflow kit come with the R-32 AMUH?

Did you know · Static pressure

How much static pressure can the R-32 AMUH push into the ducts?

LogisVert

LogisVert, system by system

Of the 16 central systems, 11 are on the Canadian ENERGY STAR list, all with the cold-climate mention: under the LogisVert guide v1.10 (September 15, 2026), $120 per 1,000 BTU/h of heating at −8 °C. The other five, all R-410A, are at $0.

The indicative amounts range from $1,272 (Centauri 12,000) to $4,464 (Centauri 48,000); the tool gives each system's amount.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about GENERAL central heat pumps

R-32 or R-410A?

The Centauri and Centauri XLTH are on R-32, the other seven systems on R-410A. On LogisVert, 5 of the 7 R-410A systems are not on the Canadian ENERGY STAR list and are at $0; all nine Centauri systems are on it, with the cold-climate mention.

Does a central heat pump replace my furnace?

It connects to your ducts through an air handler that takes an electric heater kit: optional on the R-32 AMUH, factory-provided on the R-410A AMUG. Each size's kits are on the GENERAL electric furnace page; we check your ducts on site.

Which tonnage for my house?

It is decided at your home: we look at the area to heat, insulation, windows and the size of your ducts, then suggest a tonnage. The comparator then shows every GENERAL system of that tonnage.

AirGreenGENERAL

A GENERAL central heat pump on your ducts, installed by AirGreen.

We come and see your ducts and where the air handler and the outdoor unit go, then give you the tonnage, the AHRI number and the indicative LogisVert amount of the system you choose.

Sold and installed by AirGreen.

The Centauri, 1 to 4 tons · The Centauri XLTH, down to −26 °C · GENERAL electric furnaces · Ducted units

Sources

Where the numbers come from

  1. GENERAL, 12, 18, 24, 36 and 48KUAS1M (20251124A) and 30KUAS1M (20250612A) submittals, read November 5, 2026.
  2. GENERAL, AMUH..KUAS page, airstagehvac.com; 24RGLXM, 30RGLXM, 36LMAS1, 48LMAS1, 30LUAH1M, 36LMAH1M and 48LMAH1M pages and AMUG24LMAS to AMUG48LMAS pages, GENERAL's legacy product pages, read November 5, 2026.
  3. GENERAL, press release on the RGLX medium static pressure duct units, March 11, 2019.
  4. NEEP listings 306745, 306746, 306747, 375763, 375764, 375765, 375766, 375767, 375768, 438527 and 438622, checked November 5, 2026.
  5. ENERGY STAR, Canadian market, records 2409794, 2409932, 4428945, 4428946, 4428947, 4428948, 4428949, 4428950, 4511772, 4511773 and 4511774, checked November 5, 2026.
  6. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  7. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.