AirGreen × GENERAL AIRSTAGE
Sold and installed by AirGreen.
Montreal, Laval, Longueuil, the North Shore and the South Shore.
GENERAL AIRSTAGE // Mini-VRF · J-7S
GENERAL J-7S mini-VRF: up to 12 indoor units on a single outdoor unit
26 listings: three R-32 outdoor units of 2, 3 and 4 tons, each offered with 1 to 12 indoor units depending on size. The J-7S takes over when a multi-zone system is not enough: up to 12 rooms on one outdoor unit, with a published heating limit of −26 °C.
The tool // Unit counter
How many indoor units on which outdoor unit?
Pick the size and the number of indoor units: GENERAL's limit, the accepted total and the matching listing.
J-7S 24,000 BTU AOUK024SSAN7 · 2 tons
- Indoor units
- 1 / 5 at most (minimum 1)
- Total indoor capacity accepted
- not published for the 2-ton
- Heating at −8.3 °C (ENERGY STAR)
- 17,400 BTU/h
- LogisVert, indicative amount
- $2,088
J-7S 24,000 BTU AOUK024SSAN7 · 2 tons
- Indoor units
- 2 / 5 at most (minimum 1)
- Total indoor capacity accepted
- not published for the 2-ton
- Heating at −8.3 °C (ENERGY STAR)
- 17,400 BTU/h
- LogisVert, indicative amount
- $2,088
J-7S 24,000 BTU AOUK024SSAN7 · 2 tons
- Indoor units
- 3 / 5 at most (minimum 1)
- Total indoor capacity accepted
- not published for the 2-ton
- Heating at −8.3 °C (ENERGY STAR)
- 17,400 BTU/h
- LogisVert, indicative amount
- $2,088
J-7S 24,000 BTU AOUK024SSAN7 · 2 tons
- Indoor units
- 4 / 5 at most (minimum 1)
- Total indoor capacity accepted
- not published for the 2-ton
- Heating at −8.3 °C (ENERGY STAR)
- 17,400 BTU/h
- LogisVert, indicative amount
- $2,088
J-7S 24,000 BTU AOUK024SSAN7 · 2 tons
- Indoor units
- 5 / 5 at most (minimum 1)
- Total indoor capacity accepted
- not published for the 2-ton
- Heating at −8.3 °C (ENERGY STAR)
- 17,400 BTU/h
- LogisVert, indicative amount
- $2,088
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 2-ton unit at 5 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 1 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 2 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 3 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 4 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 5 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 6 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 7 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 8 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
J-7S 36,000 BTU AOUK036SSAN7 · 3 tons
- Indoor units
- 9 / 9 at most (minimum 1)
- Total indoor capacity accepted
- 18,000 to 46,800 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- LogisVert, indicative amount
- $3,144
Not on this size
GENERAL caps the 3-ton unit at 9 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 3-ton unit at 9 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
Not on this size
GENERAL caps the 3-ton unit at 9 indoor units.
Move up a size, or split the rooms over two systems: we look at this on site.
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 1 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 2 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 3 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 4 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 5 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 6 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 7 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 8 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 9 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 10 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 11 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
J-7S 48,000 BTU AOUK048SSAN7 · 4 tons
- Indoor units
- 12 / 12 at most (minimum 1)
- Total indoor capacity accepted
- 24,000 to 62,400 BTU/h (50 to 130%)
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- LogisVert, indicative amount
- $4,296
Indoor units per size: GENERAL's J-7S submittals, p. 3 (minimum 1, maximum 5, 9 and 12). Total of 50 to 130% of the outdoor unit's capacity at 3 and 4 tons: submittals, p. 1, and J-7S press release of June 26, 2025; GENERAL does not publish that window for the 2-ton. Each room gets the indoor unit chosen for it on site, then the total must stay in the window. Heating at −8.3 °C: ENERGY STAR records 3813049, 3813050 and 3813053, checked November 5, 2026.
The three outdoor units
One sheet per size, whatever the number of indoor units
J-7S 2 tons · AOUK024SSAN7
| AHRI | 216372779 |
|---|---|
| NEEP listing | 508522 |
| ENERGY STAR Canada | 3813049 · cold climate |
| SEER2 · HSPF2 (IV) | 22.2 · 11.3 |
| Rated heating at 8.3 °C | 28,000 BTU/h |
| Heating at −8.3 °C (ENERGY STAR) | 17,400 BTU/h |
| Indoor units | 1 to 5 |
| Outdoor sound, cooling · heating | 52 · 54 dB(A) |
| Minimum circuit ampacity · breaker | 18.3 A · 20 A |
| LogisVert, indicative amount | $2,088 |
J-7S 3 tons · AOUK036SSAN7
| AHRI | 216372781 |
|---|---|
| NEEP listing | 508520 |
| ENERGY STAR Canada | 3813050 · cold climate |
| SEER2 · HSPF2 (IV) | 21.7 · 10.8 |
| Rated heating at 8.3 °C | 42,000 BTU/h |
| Heating at −8.3 °C (ENERGY STAR) | 26,200 BTU/h |
| Indoor units | 1 to 9 |
| Outdoor sound, cooling · heating | 55 · 57 dB(A) |
| Minimum circuit ampacity · breaker | 28.2 A · 30 A |
| LogisVert, indicative amount | $3,144 |
J-7S 4 tons · AOUK048SSAN7
| AHRI | 216372783 |
|---|---|
| NEEP listing | 508518 |
| ENERGY STAR Canada | 3813053 · cold climate |
| SEER2 · HSPF2 (IV) | 20.2 · 10.2 |
| Rated heating at 8.3 °C | 54,000 BTU/h |
| Heating at −8.3 °C (ENERGY STAR) | 35,800 BTU/h |
| Indoor units | 1 to 12 |
| Outdoor sound, cooling · heating | 57 · 60 dB(A) |
| Minimum circuit ampacity · breaker | 35.6 A · 40 A |
| LogisVert, indicative amount | $4,296 |
Sound, circuit and number of units: GENERAL's J-7S submittals, p. 3. NEEP and ENERGY STAR values are those of the certified combination, which mixes ducted and non-ducted units; with other indoor units, the actual output depends on the combination chosen. On these three listings, the output entered at −8.3 °C is lower than the one entered at −15 °C: we only show the ENERGY STAR value at −8.3 °C, the one LogisVert uses. Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.
The 26 J-7S listings online
Price by quote.
GENERAL // Did you know
Three details about the J-7S, from GENERAL's own documents
Did you know · The indoor units
Does the J-7S connect to the same indoor units as a residential multi-zone system?
Did you know · The footprint
Where does GENERAL say the outdoor unit can fit?
Did you know · The cap
Why does GENERAL cap the J-7S refrigerant, from the 2-ton to the 4-ton?
3 or 4 tons
What the 4-ton adds
J-7S 3 tons AOUK036SSAN7
- Heating at −8.3 °C (ENERGY STAR)
- 26,200 BTU/h
- SEER2
- 21.7
- Indoor units, at most
- 9
- Outdoor sound, cooling · heating
- 55 · 57 dB(A)
- Breaker
- 30 A
- LogisVert
- $3,144
J-7S 4 tons AOUK048SSAN7
- Heating at −8.3 °C (ENERGY STAR)
- 35,800 BTU/h
- SEER2
- 20.2
- Indoor units, at most
- 12
- Outdoor sound, cooling · heating
- 57 · 60 dB(A)
- Breaker
- 40 A
- LogisVert
- $4,296
Going from 3 to 4 tons adds 9,600 BTU/h of ENERGY STAR-listed heating at −8.3 °C and three more possible indoor units, in the same cabinet. In return: a slightly lower SEER2 (20.2 vs 21.7), 2 to 3 dB(A) more outdoors and a 40 A breaker instead of 30 A. Indicative LogisVert amounts; only Hydro-Québec confirms the assistance granted.
LogisVert
LogisVert and a mini-VRF
All three outdoor units have an AHRI number and an ENERGY STAR cold climate certification. Under the LogisVert guide v1.10 (September 15, 2026), they may be eligible for $120 per 1,000 BTU/h of heating at −8 °C, that is $2,088 (2 tons), $3,144 (3 tons) and $4,296 (4 tons), as indicative amounts.
These amounts are for each size's certified combination, which mixes ducted and non-ducted units. What a mini-VRF needs confirmed is explained in the questions below.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about the J-7S
Mini-VRF or multi-zone?
GENERAL's Aquila, RLXFZ and RLXFZH multi-zone units serve 2 to 5 rooms. The J-7S goes up to 5, 9 or 12 indoor units depending on size, with its own VRF indoor units. Beyond five rooms, it is the only GENERAL family in our catalogue that does it from one outdoor unit.
Can it run with a single indoor unit?
Yes: the J-7S submittals give a minimum of one indoor unit, on all three sizes. At 3 and 4 tons, that unit must still reach 50% of the outdoor unit's capacity, that is 18,000 or 24,000 BTU/h. The Aquila, RLXFZ and RLXFZH multi-zone units need at least two connected.
Down to what cold does it heat?
GENERAL publishes a heating range of −26 to 21 °C on all three sizes, measured at the outdoor unit's air inlet, and a built-in base pan heater against ice.
Can indoor unit types be mixed?
GENERAL's J-7S page lists four types of KSA1 indoor units: wall, compact cassette, slim ducted and multi-position air handler. The room-by-room choice is made when the system is designed, keeping the number and the total within GENERAL's limits.
Which size for my home?
That is decided on site, room by room: each room gets the unit it needs, then the total has to fit the outdoor unit's window.
Is a mini-VRF eligible for LogisVert?
Possibly. The LogisVert guide describes split and mini-split heat pumps, and the J-7S is a mini-VRF: have Hydro-Québec confirm your project's eligibility before the work. Our quote gives you the AHRI number to provide. Only Hydro-Québec confirms the assistance granted.
A J-7S for the house with many rooms, installed by AirGreen.
We come and count the rooms, see where the lines run and where the outdoor unit goes, then recommend the size and the indoor units, with the AHRI number and the indicative LogisVert amount.
Sold and installed by AirGreen.
Sources
Where the numbers come from
- GENERAL, AOUK024SSAN7 (version 20250109A), AOUK036SSAN7 and AOUK048SSAN7 (version 20250110A) submittals, p. 1 to 3: operating range, number of indoor units, sound, electrical circuit and factory charge.
- GENERAL, J-7S pages (outdoor units and overview), airstagehvac.com, read October 29, 2026; J-7S indoor units page, read November 5, 2026.
- GENERAL, "AIRSTAGE J-7S Light Commercial VRF Systems" press release, June 26, 2025.
- NEEP listings 508518, 508520 and 508522, modified September 4, 2026, checked November 5, 2026.
- ENERGY STAR, Canadian market, records 3813049, 3813050 and 3813053, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.