AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // Multi-zone

GENERAL multi-zone heat pump: one outdoor unit, two to five rooms

32 listings on 14 outdoor units and four families: Aquila and Aquila XLTH on R-32 first, then RLXFZ and RLXFZH on R-410A, also available. Each room has its own head, and GENERAL sets which heads each unit accepts.

32listings online
14outdoor units, 18,000 to 45,000 BTU
2 to 5rooms on a single outdoor unit
−26 °Cpublished limit of the Aquila XLTH and RLXFZH families
$3,720highest LogisVert amount of the multi-zone listings, at 45,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

The tool // Units by number of rooms

How many rooms? Here are the GENERAL outdoor units that serve them

The tool opens at three rooms: ten units. Move to five rooms and two remain, both 45,000; the J-7S mini-VRF, for its part, takes up to 5, 9 or 12 indoor units depending on its size.

Number of rooms
GENERAL multi-zone outdoor units for 3 rooms
Outdoor unitRefrigerantPublished limitAccepted total capacity3-room combinationsAt −15 °C, ratedLogisVert, indicative
Aquila AOUH24KWAS3R-32−15 °C14,000 to 31,000 BTUper-port rule19,200 BTU/h$1,872
Aquila AOUH36KWAS4R-32−15 °C25,000 to 46,000 BTUper-port rule24,000 BTU/h$1,180
Aquila AOUH45KWAS5R-32−15 °C34,000 to 58,000 BTUper-port rule36,000 BTU/h$3,720
Aquila XLTH AOUH24KWAH3R-32−26 °C14,000 to 31,000 BTUper-port rule25,200 BTU/h$1,944
Aquila XLTH AOUH36KWAH4R-32−26 °C25,000 to 46,000 BTUper-port rule36,400 BTU/h$2,928
RLXFZ AOU24RLXFZR-410A−15 °C14,000 to 27,000 BTU5 listedno registry value$705
RLXFZ AOU36RLXFZ1R-410A−15 °C27,000 to 39,000 BTU18 listedno registry value$0 (not on the Canadian ENERGY STAR list)
RLXFZ AOU45RLXFZR-410A−15 °C34,000 to 54,000 BTU34 listedno registry value$0 (not on the Canadian ENERGY STAR list)
RLXFZH AOU24RLXFZHR-410A−26 °C14,000 to 27,000 BTU5 listed25,600 BTU/h$1,848
RLXFZH AOU36RLXFZHR-410A−26 °C27,000 to 39,000 BTU18 listed36,400 BTU/h$2,568

3 rooms in multi-zone: 10 GENERAL outdoor units. Check my 3 heads on the 3-zone page

Rooms and accepted total: GENERAL's installation manuals and submittals, see the sources. Combinations: the Aquila per-port rule, the RLXFZ and RLXFZH numbered lists, counted for the chosen number of rooms. At −15 °C: rated heating capacity from each unit's ENERGY STAR or NEEP listing, checked November 5, 2026.

The 32 multi-zone listings online

Price by quote.

Compare // At 36,000 BTU

Aquila XLTH or Aquila: what the cold changes

Aquila XLTH 36,000 AOUH36KWAH4

At −15 °C, rated (NEEP)
36,400 BTU/h
At −8.3 °C, maximum (NEEP)
38,000 BTU/h
At −26 °C, maximum (NEEP)
22,140 BTU/h · COP 1.66
Published heating limit
−26 °C
Base pan heater
built in, per GENERAL
SEER2 · HSPF2
22.0 · 10.0
Minimum circuit ampacity · breaker
34.8 A · 35 A
Cabinet (H × W × D)
998 × 940 × 320 mm
ENERGY STAR Canada
cold climate
LogisVert, indicative
$2,928

Aquila 36,000 AOUH36KWAS4

At −15 °C, rated (NEEP)
24,000 BTU/h
At −8.3 °C, maximum (NEEP)
29,000 BTU/h
At −26 °C, maximum (NEEP)
outside the published range
Published heating limit
−15 °C
Base pan heater
not stated by GENERAL
SEER2 · HSPF2
22.0 · 10.0
Minimum circuit ampacity · breaker
24.9 A · 25 A
Cabinet (H × W × D)
884 × 820 × 315 mm
ENERGY STAR Canada
without the cold-climate mention
LogisVert, indicative
$1,180

Same ports, same 25,000 to 46,000 BTU total, same SEER2 and HSPF2: the difference is first in the cold. At −15 °C the 36,000 Aquila XLTH is rated 36,400 BTU/h, 52% more than the Aquila, and it still heats at −26 °C. It also asks more of the electrical panel, a 35 A breaker against 25 A, and a larger cabinet.

The families // R-32 and R-410A

Four families, two ways of combining heads

The Aquila units follow a per-port rule; the RLXFZ and RLXFZH, a list of numbered combinations. In the rule column, the counts 5 · 13 · 31 · 134 and 5 · 16 · 36 follow the unit sizes, smallest to largest.

The four GENERAL multi-zone families
FamilyRefrigerantOutdoor unitsRoomsPublished limitCombination ruleENERGY STAR Canada
AquilaR-3218,000, 24,000, 36,000 and 45,000 BTU2 to 5−15 °Cper port and accepted total4 / 4, 3 cold climate
Aquila XLTHR-3218,000, 24,000 and 36,000 BTU2 to 4−26 °Cper port and accepted total3 / 3, 3 cold climate
RLXFZR-410A18,000, 24,000, 36,000 and 45,000 BTU2 to 5−15 °Cnumbered list: 5 · 13 · 31 · 134 combinations2 / 4, none cold climate
RLXFZHR-410A18,000, 24,000 and 36,000 BTU2 to 4−26 °Cnumbered list: 5 · 16 · 36 combinations3 / 3, 3 cold climate

GENERAL // Did you know

Three things GENERAL writes in its multi-zone manuals

Did you know · The current

Can an Aquila's current be capped?

Did you know · Snow

Where snow falls, where does GENERAL put the outdoor unit?

Did you know · The lists

How many combinations does GENERAL list for the 45,000 RLXFZ?

LogisVert

LogisVert, unit by unit

All seven R-32 Aquila and Aquila XLTH units have a Canadian ENERGY STAR certification. Of the 14 multi-zone outdoor units, 12 have one, 9 of them with the cold-climate mention. Under the LogisVert guide v1.10 (September 15, 2026), they may be eligible for $120 per 1,000 BTU/h of heating at −8 °C with that mention, $50 without (indicative amounts). The other two, the 36,000 and 45,000 RLXFZ, are at $0.

The indicative amounts range from $695 (RLXFZ AOU18RLXFZ) to $3,720 (Aquila AOUH45KWAS5). The tool above gives each unit's amount. These amounts are for each unit's certified combination: an all non-ducted multi-zone on the NEEP registry, except for the 18,000 and 24,000 RLXFZ, listed with ENERGY STAR only, with no detail on ducts; with ducted heads the amount may differ.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about GENERAL multi-zone

How many rooms on a GENERAL multi-zone?

Two to five. The 18,000 units take two heads, the 24,000 three, the 36,000 four and the 45,000 five. Beyond five rooms, the J-7S mini-VRF, also on R-32, takes up to 12 indoor units.

Aquila or RLXFZ: what is the difference?

For the Aquila, on R-32, the installation manuals give a per-port rule and an accepted total capacity; for the RLXFZ, on R-410A, a list of numbered combinations, outside of which GENERAL does not guarantee operation. Their Aquila XLTH and RLXFZH versions have a published heating limit of −26 °C, against −15 °C.

Can wall, ducted and cassette heads share one unit?

Yes. The 2025 Aquila submittals list the compact cassette, the mid-static ducted unit, the multi-position air handler, the slim ducted unit and the wall unit; the RLXFZ submittals list the slim ducted unit, the wall unit, the compact cassette and the floor console. We check each head model on site.

What outdoor unit size for my home?

It follows from the heads: we first set the size of each room on site, then pick the outdoor unit whose ports and accepted total suit the whole set.

AirGreenGENERAL

Several rooms, one outdoor unit, installed by AirGreen.

We come and see each room and where the outdoor unit goes, choose the family and the heads with you, then give you the AHRI number and indicative LogisVert amount of the system you choose.

Sold and installed by AirGreen.

2 zones · 3 zones · 4 zones · 5 zones · More than five rooms: the J-7S

Sources

Where the numbers come from

  1. GENERAL, 18KWAS2 (20250618A), 24KWAS3 (20250618A), 36KWAS4 (20250619A), 45KWAS5 (20250618A), 18KWAH2 (20250618A), 24KWAH3 (20250618A) and 36KWAH4 (20250619A) submittals.
  2. GENERAL, Aquila installation manuals, ref. 9300793117-03 and 9379113397-02: number of indoor units, accepted total capacity and size per port (all 7 Aquila and Aquila XLTH units).
  3. GENERAL, RLXFZ and RLXFZH installation manuals, ref. 9374747146, 9374747153 and 9380545101-06: numbered lists of combinations, read November 5, 2026.
  4. GENERAL, RLXFZ and RLXFZH submittals (all 7 RLXFZ and RLXFZH units): 18RLXFZ, 24RLXFZ, 36RLXFZ1, 45RLXFZ, 18RLXFZH and 36RLXFZH, effective January 10, 2023; 24RLXFZH, October 22, 2019.
  5. The 2019 24RLXFZH submittal prints a total of 14,000 to 21,000 BTU/h; we follow installation manual 9374747153, p. En-3 and En-4, which gives 14,000 to 27,000 BTU and lists 15,000 + 12,000 and 9,000 + 9,000 + 9,000.
  6. GENERAL, Aquila (KWAS) and Aquila XLTH (KWAH) pages on its US site, read November 5, 2026.
  7. NEEP, multi-zone outdoor-unit listings 385699, 385701, 438660, 438666, 438668, 455167, 455168, 455169, 455170 and 455171, checked November 5, 2026.
  8. ENERGY STAR, Canadian market, records of the 12 certified units 2409923, 2409925, 2409928, 2409935, 2409939, 3627390, 3627392, 3627394, 3627396, 3627398, 3630082 and 3630083, checked November 5, 2026.
  9. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  10. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.