AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // 4 zones

GENERAL 4-zone heat pump: six outdoor units, and the total of the four heads decides

6 four-head listings, on six 36,000 and 45,000 GENERAL multi-zone outdoor units: three R-32 Aquila and Aquila XLTH units, and three R-410A RLXFZ and RLXFZH units, also available. The smallest of the four heads is always 12,000 BTU or less, and the total of all four must not exceed what the unit accepts.

64-zone listings online
6GENERAL multi-zone outdoor units for four rooms, 3 of them on R-32
−26 °Cpublished limit of 2 of the 6 units: Aquila XLTH and RLXFZH
$3,720highest LogisVert amount of these listings, at 45,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

The tool // Four heads, one total

Four heads: which units accept all of them?

The tool opens on 9,000 + 9,000 + 12,000 + 12,000, that is 42,000 BTU: all three Aquila units accept it, and among the R-410A units, only the 45,000 RLXFZ. Swap a 12,000 head for a 9,000: the 36,000 RLXFZH then accepts it (no. 32), not the 36,000 RLXFZ, whose list does not include 12 + 9 + 9 + 9.

Total capacity 42,000 BTU

  • Aquila AOUH36KWAS4

    R-32 · published limit −15 °C · accepted total 25,000 to 46,000 BTU

    Largest head per port: A 24,000 · B 18,000 · C 15,000 · D 9,000

    Within the manual's rules
  • Aquila AOUH45KWAS5

    R-32 · published limit −15 °C · accepted total 34,000 to 58,000 BTU

    Largest head per port: A 24,000 · B 24,000 · C 18,000 · D 12,000 · E 9,000

    Within the manual's rules
  • Aquila XLTH AOUH36KWAH4

    R-32 · published limit −26 °C · accepted total 25,000 to 46,000 BTU

    Largest head per port: A 24,000 · B 18,000 · C 15,000 · D 9,000

    Within the manual's rules
  • RLXFZ AOU36RLXFZ1

    R-410A · published limit −15 °C · accepted total 27,000 to 39,000 BTU

    12 four-room combinations listed by GENERAL (manual 9374747153, p. En-3)

    Nototal over the accepted maximum
  • RLXFZ AOU45RLXFZ

    R-410A · published limit −15 °C · accepted total 34,000 to 54,000 BTU

    55 four-room combinations listed by GENERAL (manual 9380545101-06, p. En-4 and En-5)

    On GENERAL's list, no. 87
  • RLXFZH AOU36RLXFZH

    R-410A · published limit −26 °C · accepted total 27,000 to 39,000 BTU

    13 four-room combinations listed by GENERAL (manual 9380545101-06, p. En-5)

    Nototal over the accepted maximum

Four heads: the 3 Aquila and Aquila XLTH units pass if each head fits its port and the total stays in the accepted range (manuals 9300793117-03 and 9379113397-02); the 3 RLXFZ and RLXFZH units, only if your set of four is among the 80 that GENERAL lists for four rooms (manuals 9374747153 and 9380545101-06).

The 6 4-zone listings online

Price by quote.

GENERAL // Did you know

Three GENERAL rules specific to four rooms

Did you know · The 24,000 head

A 24,000 head among four, is it possible?

Did you know · The minimum

Four 7,000 heads on the 45,000 Aquila?

Did you know · The 18,000 head

On the 36,000 RLXFZ, four rooms with an 18,000 head?

LogisVert

LogisVert for four rooms

For four rooms, the highest indicative amount is the 45,000 Aquila's: $3,720, for 31,000 BTU/h of heating at −8 °C listed with ENERGY STAR with the cold-climate mention. Under the LogisVert guide v1.10 (September 15, 2026), a unit may be eligible for $120 per 1,000 BTU/h with that mention, $50 without, and nothing without a Canadian ENERGY STAR certification.

Indicative amounts by outdoor unit: Aquila AOUH36KWAS4: $1,180; Aquila AOUH45KWAS5: $3,720; Aquila XLTH AOUH36KWAH4: $2,928; RLXFZ AOU36RLXFZ1: $0 (not on the Canadian ENERGY STAR list); RLXFZ AOU45RLXFZ: $0 (not on the Canadian ENERGY STAR list); RLXFZH AOU36RLXFZH: $2,568. These figures assume each unit's certified combination, non-ducted according to the NEEP registry; with one or more ducted heads among the four, the amount may be different.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about 4-zone systems

Which GENERAL units serve four rooms?

In multi-zone, six: the 36,000 Aquila and Aquila XLTH, the 45,000 Aquila, the 36,000 and 45,000 RLXFZ, and the 36,000 RLXFZH. No Aquila, RLXFZ or RLXFZH unit below 36,000 takes four heads. All three sizes of the J-7S mini-VRF take four too, and up to 5, 9 or 12.

Do the 36,000 Aquila units take 9,000 + 9,000 + 12,000 + 12,000?

Yes: 42,000 BTU fits under their 46,000 BTU ceiling, and the 45,000 Aquila takes them too. On the R-410A side, the 45,000 RLXFZ accepts them, as its combination no. 87, but not the 36,000 RLXFZ or RLXFZH, which stop at 39,000 BTU.

How much line set for four rooms?

At most 70 m in total on the 36,000 units and 80 m on the 45,000 units, with 25 m per head. The AOU36RLXFZ1 also needs at least 20 m in total, against 15 m for the other 36,000 units.

How are the four head sizes chosen?

Room by room, during the on-site assessment: a basement bedroom and a living room with lots of glass do not have the same needs. We then check that the four sizes chosen form a combination the outdoor unit accepts.

AirGreenGENERAL

Four rooms, one outdoor unit, installed by AirGreen.

We come and see the four rooms and each line route, choose the heads and the 36,000 or 45,000 unit with you, then give you the AHRI number and the indicative LogisVert amount.

Sold and installed by AirGreen.

Compare the multi-zone families · See 3 zones · See 5 zones · The J-7S mini-VRF

Sources

Where the numbers come from

  1. GENERAL, 36KWAS4 (20250619A), 45KWAS5 (20250618A) and 36KWAH4 (20250619A) submittals.
  2. GENERAL, Aquila installation manuals, ref. 9300793117-03 and 9379113397-02: number of indoor units, accepted total capacity and size per port (four-room combinations).
  3. GENERAL, RLXFZ and RLXFZH installation manuals, ref. 9374747153 and 9380545101-06: numbered lists of four-room combinations, read November 5, 2026.
  4. GENERAL, RLXFZ and RLXFZH submittals (four-room combinations): 36RLXFZ1, 45RLXFZ and 36RLXFZH, effective January 10, 2023.
  5. NEEP listings 385699, 385701, 438660 and 455169, checked November 5, 2026.
  6. ENERGY STAR, Canadian market, records 2409925, 3627394, 3630082 and 3630083, checked November 5, 2026.
  7. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  8. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.